A flip-chip-type gradiometer has been constructed with a 10 mm × 5 mm planar DCSQUID gradiometer fabricated on a SrTiO3 bicrystal substrate and a flux transformer made from a YBCO*/YBCO/CeO2/YSZ multilayer on ?50...A flip-chip-type gradiometer has been constructed with a 10 mm × 5 mm planar DCSQUID gradiometer fabricated on a SrTiO3 bicrystal substrate and a flux transformer made from a YBCO*/YBCO/CeO2/YSZ multilayer on ?50.8 mm Si wafer. The coupling coefficient between the flux transformer and the planar gradiometer is 0.18. The transformer increases effectively the resolution of the gradiometer. A magnetic field gradient resolution of 73 fT.cm?1Hz?1/2 in the white region and 596 fT.cm?1Hz?1/2 at 1 Hz has been obtained. High quality magnetocardiogram signals have been successfully measured by using this flip-chip-type gradiometer in an unshielded environment.展开更多
Considering the properties of slow change and quasi-periodicity of magnetocardiography (MCG) signal, we use an integrated technique of adaptive and low-pass filtering in dealing with two-channel MCG data measured by...Considering the properties of slow change and quasi-periodicity of magnetocardiography (MCG) signal, we use an integrated technique of adaptive and low-pass filtering in dealing with two-channel MCG data measured by high Tc SQUIDs. The adaptive filter in the time domain is based on a noise feedback normalized least-mean-square (NLMS) algorithm, and the low-pass filter with a cutoff at 100Hz in the frequeucy domain characterized by Caussian functions is combined with a notch at the power line frequency. In this way, both relevant and irrelevant noises in original MCG data are largely eliminated. The method may also be useful for other slowly varying quasi-periodical signals.展开更多
文摘A flip-chip-type gradiometer has been constructed with a 10 mm × 5 mm planar DCSQUID gradiometer fabricated on a SrTiO3 bicrystal substrate and a flux transformer made from a YBCO*/YBCO/CeO2/YSZ multilayer on ?50.8 mm Si wafer. The coupling coefficient between the flux transformer and the planar gradiometer is 0.18. The transformer increases effectively the resolution of the gradiometer. A magnetic field gradient resolution of 73 fT.cm?1Hz?1/2 in the white region and 596 fT.cm?1Hz?1/2 at 1 Hz has been obtained. High quality magnetocardiogram signals have been successfully measured by using this flip-chip-type gradiometer in an unshielded environment.
文摘Considering the properties of slow change and quasi-periodicity of magnetocardiography (MCG) signal, we use an integrated technique of adaptive and low-pass filtering in dealing with two-channel MCG data measured by high Tc SQUIDs. The adaptive filter in the time domain is based on a noise feedback normalized least-mean-square (NLMS) algorithm, and the low-pass filter with a cutoff at 100Hz in the frequeucy domain characterized by Caussian functions is combined with a notch at the power line frequency. In this way, both relevant and irrelevant noises in original MCG data are largely eliminated. The method may also be useful for other slowly varying quasi-periodical signals.