期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Experimental investigation on flow characteristics in circular tube inserted with rotor-assembled strand using PIV 被引量:4
1
作者 Lichen He Weimin Yang +3 位作者 Changfeng Guan Hua Yan Lin Zheng Xiahua Zuo 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第1期1-9,共9页
Rotor-assembled strand works as a typical tube insert to achieve heat transfer augmentation and scale inhibition in a heat exchanger.In this work, the PIV experiment regarding the flow fields in a circular tube insert... Rotor-assembled strand works as a typical tube insert to achieve heat transfer augmentation and scale inhibition in a heat exchanger.In this work, the PIV experiment regarding the flow fields in a circular tube inserted with rotor-assembled strand was conducted and the flow characteristics on transverse section and longitudinal section were analyzed.The results showed that swirling flow was produced in the tube inserted with rotors and it was particularly strong within the swing diameter of the rotor on the section that contains the rotor;the average turbulence intensity and the radial velocity were improved notably; the velocity vectors on the longitudinal section remained along the direction of a straight line; both the swirling flow and average turbulence intensity were higher for the rotor with three blades than for the rotor with two blades except that the radial velocity was approximate, but they were all reduced by enlarging the lead of the rotor.Characterization of the flow patterns in a circular tube contributes to understanding the heat transfer efficiency and scale inhibition performance of the rotor-assembled strand and provides guidance for its application. 展开更多
关键词 Particle image VELOCIMETRY (PIV) Swirling flow rotor-assembled STRAND CIRCULAR tube
下载PDF
xperimental Study of Heat Transfer Enhancement and Friction Loss Induced by Inserted Rotor-assembled Strand (I) Water 被引量:4
2
作者 谢鹏程 李锋祥 +3 位作者 丁玉梅 阎华 关昌峰 杨卫民 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第6期849-855,共7页
The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental sy... The single-phase pressure drop and heat transfer in a rotor-assembled strand inserted tube were measured using water as the working fluid.Experiment using a smooth tube was carried out to calibrate the experimental system and the data reduction method.In the experiment,fixed mounts were used to eliminate the entrance effect. The experimental results of smooth tube show that employment of fixed mounts leads to a visible bias of friction factor at relative low Reynolds numbers,although it does not significantly affect the Nusselt numbers.The measured data of inserted tube reveal that rotor-assembled strand can significantly improve heat transfer with the Nusselt number increased by 101.6%-106.6%and the overall heat transfer coefficient increased by 58.1%-67.4%within the Reynolds number range of 20000 to 36000.Meanwhile,friction factor increases by 52.2%-84.2%within the same Reynolds number range.The correlations of Nusselt number and friction factor as function of the Reynolds number and Prandtl number were determined through multivariant linear normal regression. 展开更多
关键词 heat transfer enhancement rotor-assembled strand friction factor DEPENDENCY
下载PDF
Experimental Study of Heat Transfer Enhancement and Friction Loss Induced by Inserted Rotor-assembled Strand (II) Lubricant Oil 22 被引量:1
3
作者 韩崇刚 杨卫民 +4 位作者 丁玉梅 关昌峰 李锋祥 张震 阎华 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第6期1069-1074,共6页
The paper described experimental investigation of heat transfer and single-phase pressure drop through tubes with different rotor-assembled strands inserted in the Reynolds number range of 800-9000 with lubricant as w... The paper described experimental investigation of heat transfer and single-phase pressure drop through tubes with different rotor-assembled strands inserted in the Reynolds number range of 800-9000 with lubricant as working fluid. In the experiment, fixed mounts were employed to eliminate the entrance effect. The experimental results showed that the employment of fixed mounts led to a visible bias of friction factor in the laminar regime while it could not affect the Nusselt numbers significantly. Experiment for the tube inserted with rotors-assembled strand showed remarkable improvement for heat transfer with the Nusselt number increased by 200%-225% in the laminar regime and 125%-160% in the transitional regime. Meanwhile, the friction factor increased inevitably by 200%-300% within the same range of Reynolds number. The comparison of different rotor-assembled strands in-serted tubes and plain tube showed that the heat transfer benefited from the increase of the diameter of rotor-assembled strand with the same lead and the decrease of the lead of rotor-assembled strand, so does the friction factor. Based on experimental data and thorough multivariant linear normal regression method, the correlations of average Nusselt number and friction factor are established. 展开更多
关键词 heat transfer enhancement rotor-assembled strand friction factor thermal performance factor
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部