期刊文献+
共找到36篇文章
< 1 2 >
每页显示 20 50 100
A comparative laboratory diagnosis of malaria:microscopy versus rapid diagnostic test kits 被引量:3
1
作者 Azikiwe CCA Ifezulike CC +3 位作者 Siminialayi IM Amazu LU Enye JC Nwakwunite OE 《Asian Pacific Journal of Tropical Biomedicine》 SCIE CAS 2012年第4期307-310,共4页
Objective:To compare the two methods of rapid diagnostic tests(RDTs)and microscopy in the diagnosis of malaria.Methods:RDTs and microscopy were carried out to diagnose malaria. Percentage malaria parasitaemia was calc... Objective:To compare the two methods of rapid diagnostic tests(RDTs)and microscopy in the diagnosis of malaria.Methods:RDTs and microscopy were carried out to diagnose malaria. Percentage malaria parasitaemia was calculated on thin films and all non-acute cases of plasmodiasis with less than 0.001%malaria parasitaemia were regarded as negative.Results were simply presented as percentage positive of the total number of patients under study.The results of RDTs were compared to those of microscopy while those of RDTs based on antigen were compared to those of RDTs based on antibody.Patients' follow-up was made for all cases.Results: All the 200 patients under present study tested positive to RDTs based on malaria antibodies(serum)method(100%).128 out of 200 tested positive to RDTs based on malaria antigen(whole blood)method(64%),while 118 out of 200 patients under present study tested positive to visual microscopy of Lieshman and diluted Giemsa(59%).All patients that tested positive to microscopy also tested positive to RDTs based on antigen.All patients on the second day of follow-up were non-febrile and had antimalaria drugs.Conclusions;We conclude based on the present study that the RDTs based on malaria antigen(whole blood)method is as specific as the traditional microscopy and even appears more sensitive than microscopy.The RDTs based on antibody(serum)method is unspecific thus it should not be encouraged.It is most likely that Africa being an endemic region,formation of certain levels of malaria antibody may not be uncommon.The present study also supports the opinion that a good number of febrile cases is not due to malaria. We support WHO's report on cost effectiveness of RDTs but,recommend that only the antigen based method should possibly,be adopted in Africa and other malaria endemic regions of the world. 展开更多
关键词 rapid diagnostic tests MICROSCOPY MALARIA diagnosis MALARIA PARASITAEMIA Plasmodiasis ANTIGEN ANTIBODY ANTIMALARIA Serum Whole blood
下载PDF
互联网上销售的HIV抗体快速检测试剂物理性能和灵敏度调查 被引量:4
2
作者 任雅楠 马仲慧 +4 位作者 徐冰 王俊 裴丽健 蒋岩 邢文革 《中国艾滋病性病》 CAS CSCD 北大核心 2020年第3期243-246,共4页
目的了解互联网上销售艾滋病病毒(HIV)抗体快速检测试剂的现状,评价试剂的物理性能和分析灵敏度,分析用于自我检测时可能存在的问题。方法通过比较互联网上购买HIV抗体快速检测试剂的包装、预期用途、样本类型等,评价其物理性能;通过检... 目的了解互联网上销售艾滋病病毒(HIV)抗体快速检测试剂的现状,评价试剂的物理性能和分析灵敏度,分析用于自我检测时可能存在的问题。方法通过比较互联网上购买HIV抗体快速检测试剂的包装、预期用途、样本类型等,评价其物理性能;通过检测最低检出限样本,评价其分析灵敏度。结果 32种互联网上销售的HIV抗体快速检测试剂包装中9种有图片式说明材料(9/32),31种有样本采集装置(31/32)。说明书中2种的预期用途为无偿献血现场初筛(2/32),5种为自愿咨询检测(5/32),1种为消费者自检(1/32);25种结果解释中没有后续处理方法(25/32);13种互联网销售的HIV抗体血液快速检测剂没有指尖血采集步骤(13/18),1种只能检测血清和血浆(1/18)。29种互联网上销售HIV抗体快速检测试剂检测最低检出限样本均为反应性结果(29/29)。结论专业实验室使用的试剂用于自我检测时存在的问题:HIV血液抗体快速检测试剂没有配备采血针、没有指尖血采集步骤;没有图片式说明材料;结果解释中没有介绍后续处理方法等。 展开更多
关键词 互联网 艾滋病病毒 快速检测 性能评价
原文传递
Comparison of Microscopic Determination and Rapid Diagnostic Tests (RDTs) in the Detection of Plasmodium Infection 被引量:1
3
作者 Onyeka Linda Anagu Moses Nkechukwu Ikegbunam +2 位作者 Chinelo Kene Unachukwu Ogwaluonye Uchenna C Charles Okey Esimone 《Advances in Microbiology》 2015年第8期604-609,共6页
Malaria infection is the most common diagnosis made in Africa. Efficient diagnosis of malaria parasite is very vital for treatment of malaria infection. The efficacy of rapid diagnostic tests (RDTs) in comparison to m... Malaria infection is the most common diagnosis made in Africa. Efficient diagnosis of malaria parasite is very vital for treatment of malaria infection. The efficacy of rapid diagnostic tests (RDTs) in comparison to microscopy, the gold standard, in the diagnosis of malaria in Nigeria has not been fully ascertained. This study compared the sensitivity, specificity and predictive values of RDTs available in Nigeria market with microscopy. Two RDT kits were used and their results were compared with the gold standard, microscopy using thick and thin blood films (TBF and tBF). TBF had sensitivity of 85%, specificity of 30%, positive predictive value (PPV) of 55.2%, and negative predictive value (NPV) of 66.6%;tBF had sensitivity of 80%, specificity of 35%, positive predictive value (PPV) of 55.2%, and negative predictive value (NPV) of 63.6%. Among the RDTs, Care Start HRP2 kit had sensitivity of 65%, specificity of 50%, positive predictive value (PPV) of 56.5%, and negative predictive value (NPV) of 59% while SD Bioline kit had sensitivity of 55%, specificity of 65%, PPV of 61%, and NPV of 59%. It can thus be inferred that rapid diagnostic test kits are not as sensitive as microscopy in diagnosis of malaria parasite, but they are more accurate and are thus suitable alternatives to microscopy. 展开更多
关键词 PLASMODIUM falciparium MICROSCOPY rapid diagnostic tests
下载PDF
A retrospective evaluation of the quality of malaria case management at twelve health facilities in four districts in Zambia 被引量:1
4
作者 Pascalina Chanda-Kapata Emmanuel Chanda +3 位作者 Freddie Masaninga Annette Habluetzel Felix Masiye Ibrahima Soce Fall 《Asian Pacific Journal of Tropical Biomedicine》 SCIE CAS 2014年第6期498-504,共7页
Objective:To establish the appropriateness of malaria case management at health facility level in four districts in Zambia.Methods:This study was a retrospective evaluation of the quality of malaria case management at... Objective:To establish the appropriateness of malaria case management at health facility level in four districts in Zambia.Methods:This study was a retrospective evaluation of the quality of malaria case management at health facilities in four districts conveniently sampled to represent both urban and rural settings in different epidemiological zones and health facility coverage.The review period was from January to December 2008.The sample included twelve lower level health facilities from four districts.The Pearson Chi-square test was used to identify characteristics which affected the quality of case management.Results:Out of 4891 suspected malaria cases recorded at the 12 health facilities,more than 80%of the patients had a temperature taken to establish their fever status.About 67%(CI_(95)66.1-68.7)were tested for parasitemia by either rapid diagnostic test or microscopy,whereas the remaining22.5%(CI_(95)213.1-23.7)were not subjected to any malaria test.Of the 2247 malaria cases reported(complicated and uncomplicated),71%were parasitologicaily confirmed while 29%were clinically diagnosed(unconfirmed).About 56%.(CI_(95)53.9-58.1)of the malaria cases reported were treated with artemether-lumefantrine(AL),35%(CI_(95)33.1-37.0)with sulphadoxine-pyrimethamine,8%(CI_(95)6.9-9.2)with quinine and 1%did not receive any anti-malarial.Approximately 30%of patients WHO were found negative for malaria parasites were still prescribed an anti-malarial,contrary to the guidelines.There were marked inter-district variations in the proportion of patients in WHOm a diagnostic tool was used,and in the choice of anti-malarials for the treatment of malaria confirmed cases.Association between health worker characteristics and quality of case malaria management showed that nurses performed better than environmental health technicians and clinical officers on the decision whether to use the rapid diagnostic test or not.Gender,in service training on malaria,years of residence in the district and length of service of the health worker a 展开更多
关键词 MALARIA QUALITY Diagnosis Treatment ANTIMALARIALS Microscopy rapid diagnostic tests Zambia
下载PDF
血液/口腔黏膜渗出液/尿液HIV抗体快速检测试剂的性能评价 被引量:2
5
作者 任雅楠 马仲慧 +6 位作者 徐冰 王俊 王月华 裴丽健 潘品良 蒋岩 邢文革 《中国艾滋病性病》 CAS CSCD 北大核心 2020年第7期682-685,共4页
目的构建血液、口腔黏膜渗出液(OMT)、尿液HIV抗体快速评价盘,评价3种血液,2种OMT和1种尿液HIV抗体快速检测试剂的性能。方法用血液、OMT、尿液国家参考品,实验室评价盘(包括实验室基础盘、实验室干扰盘、实验室稀释系列盘、实验室精密... 目的构建血液、口腔黏膜渗出液(OMT)、尿液HIV抗体快速评价盘,评价3种血液,2种OMT和1种尿液HIV抗体快速检测试剂的性能。方法用血液、OMT、尿液国家参考品,实验室评价盘(包括实验室基础盘、实验室干扰盘、实验室稀释系列盘、实验室精密度盘),商业阳转血清盘,对6种(3种血液,2种OMT和1种尿液)HIV抗体快速检测试剂进行评价,肉眼判读结果,并用金标免疫层析试纸读数仪测定相应的GOD值。结果1)6种试剂的阴性参考品符合率均为20/20,HIV-1阳性参考品符合率均为18/18,3种血液和2种OMT试剂的HIV-2阳性参考品符合率均为2/2。2)3种血液试剂的阳性样本符合率和阴性样本符合率均为40/40,2种OMT试剂的阳性样本符合率均为40/40,阴性样本符合率分别为40/40和38/40。尿液试剂的阳性样本符合率和阴性样本符合率为30/30。3)3种血液试剂的分析灵敏度均为2/3,2种OMT试剂的分析灵敏度分别为3/5和0/5,尿液试剂的分析灵敏度为3/5。4)3种血液试剂的分析特异性均为45/45,2家OMT试剂的分析特异性分别为45/45和36/45,尿液试剂的分析特异性为45/45。5)GOD结果显示6家试剂的批内精密度在7.8%~44.0%之间。结论6家试剂的阴性参考品符合率,阳性参考品符合率,阳性样本符合率、阴性样本符合率均较好。1家OMT试剂的分析灵敏度和分析特异性较差,6种试剂的批内精密度存在差异。 展开更多
关键词 血液 口腔黏膜渗出液 尿液 艾滋病病毒 快速检测试剂
原文传递
Diagnosis of Malaria among Blood Donors in Port Harcourt, Nigeria: Microscopy or Rapid Diagnostic Tests?
6
作者 Kennedy T. Wariso Ibinabo L. Oboro 《Advances in Microbiology》 2015年第5期358-363,共6页
The two most common techniques available for diagnosis of malaria in Nigeria are microscopy and rapid diagnostic tests (RDTs). However, in diagnosing asymptomatic Plasmodium parasitaemia among donors, the preferred te... The two most common techniques available for diagnosis of malaria in Nigeria are microscopy and rapid diagnostic tests (RDTs). However, in diagnosing asymptomatic Plasmodium parasitaemia among donors, the preferred technique should not only be timely but must not compromise diagnosis. It should be more sensitive with minimal chances of false negative results. This study was carried out to compare microscopy and RDTs as effective tools for diagnosis of Plasmodium parasitaemia among blood donors in Port Harcourt. There were 200 donors involved in the study among which 135 (67.5%) tested positive and 65 (32.5%) tested negative on microscopy whereas 30 (15.0%) tested positive and 170 (85.0%) tested negative to RDT with a statistically significant difference between both techniques. Data were analysed using the statistical package epi-info version 7.02. We therefore recommend that microscopy using giemsa-stained blood films remain the method of choice for diagnosis of Plasmodium parasitaemia among blood donors to prevent the spread of transfusion malaria. 展开更多
关键词 BLOOD DONORS MICROSCOPY rapid diagnostic tests
下载PDF
Evaluation of Three Rapid Diagnostic Test Kits in the Diagnosis of <i>Plasmodium</i>Species Infections among Primary School Children in Baringo County, Kenya
7
作者 Collince Jared Omondi Lucy Muthony Kamau +3 位作者 Humphrey Kariuki Njaanake Douglas Anyona Daniel Onguru Benson Estambale 《Open Journal of Clinical Diagnostics》 2017年第1期31-44,共14页
Background: Due to the difficulty in implementing microscopy-based definitive diagnosis of malaria especially in resource-poor areas, rapid diagnostic test (RDT) kits as alternatives have been developed by different c... Background: Due to the difficulty in implementing microscopy-based definitive diagnosis of malaria especially in resource-poor areas, rapid diagnostic test (RDT) kits as alternatives have been developed by different companies. Kits from different companies may differ in sensitivity and specificity. It is therefore imperative to conduct field evaluation of kits from different manufacturers before they are recommended for widespread use in diagnosis of malaria. The present study sought to evaluate the performance of malaria RDT kits from two manufacturers against microscopy in detection of Plasmodium spp. infections among primary school children in Baringo County, Kenya. Methods: Two cross-sectional comparative surveys to assess three RDT kits (CareStart HRP-2, SD Bioline Ag-Pf and SD Bioline Ag-Pf/Pan) were conducted on 561 pupils from three primary schools within the Kerio Valley of Baringo County, Kenya. Results: A total of 561 blood samples were tested for Plasmodium spp. within a period of four months. SD Bioline Ag-Pf/ Pan RDT kit had a higher sensitivity (90%) compared to that of CareStart HRP-2 (70%) but this was not statistically significant (McNemar’s χ2 = 0.5, df = 1, p = 0.4795). The sensitivity of SD Bioline Ag-Pf was the same as that of Care Start HRP-2 (82.4%). The number of positive samples by microscopy was relatively lower than those detected by RDT kits. Two cases of non-P. falciparum infections were detected by RDT kits during the second survey. Conclusion: The results of the present study suggest that the performance of the three kits in the diagnosis of P. falciparum infections was better than microscopy. The sensitivity of SD Bioline Ag-Pf/Pan was slightly greater than that of Care Start HRP-2, although not statistically different. 展开更多
关键词 rapid diagnostic tests Microscopy MALARIA Sensitivity SPECIFICITY Baringo
下载PDF
Assessment of Rapid Diagnostic Tests Algorithms in Transfusion Medicine Setting
8
作者 Modibo Coulibaly Bakary Maiga +6 位作者 Dramane Samaké Moussa Diawara Mahamadou Traoré Valentin Sagara Bréhima Traoré Oumar Guindo Amagana Dolo 《Advances in Biological Chemistry》 2021年第1期52-63,共12页
<span style="font-family:Verdana;"><strong>Background:</strong></span><span><span><span style="font-family:""><span style="font-family:Verdana... <span style="font-family:Verdana;"><strong>Background:</strong></span><span><span><span style="font-family:""><span style="font-family:Verdana;"> The rapid diagnostic tests play a pivotal role in the screening of viral markers in blood qualification for transfusion in limited resource setting. Therefore, it is important to assess their analytical performances to ensure their proper functioning. </span><b><span style="font-family:Verdana;">Material</span></b> <b><span style="font-family:Verdana;">and</span></b> <b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> We performed a cross-</span></span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">sectional study by successive recruitment to assess the diagnostic value of rapid diagnostic tests algorithms using ELISA as a reference test. A total of 661 blood from donors were enrolled for this study. Rapid Diagnostic Tests (RDTs) and ELISA tests were performed for each sample by a couple of double-blinded biotechnologists. Data were collected on case report form and captured in Microsoft Excel then the file was imported and analyzed using R software version 4.0.3. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> The diagnostic accuracy for the algorithms are summarized in </span><b><span style="font-family:Verdana;">Table 1</span></b><span style="font-family:Verdana;">. For HIV-algorithm</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> the internal validity parameters were as follow: sensitivity (sens) 99.0% (95% CI = 97.8, 99.5);specificity (spec) 98.3% (95% CI = 90.9, 99.7);positive likelihood ratio (PLR) 57.4 (95% CI = 8.2, 401.0);negative likelihood ratio (NLR) 0.01 展开更多
关键词 rapid diagnostic tests Analytical Performances ASSESSMENT Transfusion Medicine
下载PDF
普3通光学显微镜诊断疟疾的历史及其发展 被引量:1
9
作者 李玉刚 张再兴 《国际医学寄生虫病杂志》 CAS 2010年第5期314-322,共9页
疟疾是严重危害人类健康尤其是热带地区的重要传染病之一。在人类控制疟疾的过程中,普通光学显微镜由于其准确性高、相对低廉的费用及提供的大量信息发挥了极大作用,至今还广泛应用于诊断与科研中。但是由于显微镜检疟疾存在许多不足... 疟疾是严重危害人类健康尤其是热带地区的重要传染病之一。在人类控制疟疾的过程中,普通光学显微镜由于其准确性高、相对低廉的费用及提供的大量信息发挥了极大作用,至今还广泛应用于诊断与科研中。但是由于显微镜检疟疾存在许多不足之处,如需要培训专门的镜检人员,镜检效率低,尤其是当血中疟原虫密度较低时其敏感性亦较低而倍受诟病。再加上近些年基于抗原抗体反应的各种快速诊断方法不断取得进展,使得现场显微镜诊断疟疾在未来有被取代的可能,或许光学显微镜对疟原虫的用途只保留在形态学研究中。 展开更多
关键词 疟疾 临床诊断 光学显微镜 荧光素 快速诊断法
原文传递
三种SARS-CoV-2抗体胶体金试剂诊断效能评价及假阳性控制策略探讨 被引量:7
10
作者 王远芳 邓杰伦 +3 位作者 敖科萍 李冬冬 谢轶 应斌武 《中国呼吸与危重监护杂志》 CAS CSCD 北大核心 2020年第3期214-218,共5页
目的探讨胶体金免疫层析法(GICA)在新型冠状病毒(SARS-CoV-2)检测中的价值。方法收集四川大学华西医院2020年1至2月期间12例SARS-CoV-2感染患者的33份血清,以及45例排除SARS-CoV-2感染患者的45份血清,采用三种不同厂家的GICA检测试剂盒... 目的探讨胶体金免疫层析法(GICA)在新型冠状病毒(SARS-CoV-2)检测中的价值。方法收集四川大学华西医院2020年1至2月期间12例SARS-CoV-2感染患者的33份血清,以及45例排除SARS-CoV-2感染患者的45份血清,采用三种不同厂家的GICA检测试剂盒进行检测。结果三种GICA试剂的敏感性、特异性、阳性预测值和阴性预测值分别为66.7%~90.9%、73.3%~100.0%、71.4%~100.0%和80.4%~91.7%。漏诊率为9.1%~33.3%,误诊率为0~26.7%,约登指数为0.64~0.79。检出率随样本稀释滴度的增加而降低,1∶4及以上滴度水平时所有试剂的阳性检出率均超过50%。检测干扰因素主要包括人类免疫缺陷病毒感染、高类风湿因子、溶血。结论临床实验室应注意不同试剂的检测能力和潜在交叉反应的差异,或使用多种抗体的组合。 展开更多
关键词 新型冠状病毒 IgM/IgG抗体 金标法快速检测
原文传递
5种RDTs检测间日疟原虫和卵形疟原虫效果评价及影响因素研究 被引量:1
11
作者 许艳 王龙江 +7 位作者 陈春梅 李林林 隋苗苗 孔祥礼 张本光 李曰进 闫歌 王用斌 《中国病原生物学杂志》 CSCD 北大核心 2022年第9期1040-1044,共5页
目的评价5种常见疟疾快速诊断试剂盒(RDTs)对间日疟原虫和卵形疟原虫的检测效果,并分析影响检测结果的因素,为医疗机构选择和应用RDTs提供参考依据。方法按照各试剂盒说明书操作,分别用万孚、BinaxNOW、SD、蓝十字和伊仕5种RDTs检测间... 目的评价5种常见疟疾快速诊断试剂盒(RDTs)对间日疟原虫和卵形疟原虫的检测效果,并分析影响检测结果的因素,为医疗机构选择和应用RDTs提供参考依据。方法按照各试剂盒说明书操作,分别用万孚、BinaxNOW、SD、蓝十字和伊仕5种RDTs检测间日疟确诊病例血样、卵形疟确诊病例血样和阴性血样。采用诊断试验的方法,评价5种RDTs检测间日疟原虫和卵形疟原虫的灵敏度和特异度,比较不同RDTs检测灵敏度间的差异。并分析卵形疟亚型、感染来源对RDTs检测结果的影响。结果万孚、BinaxNOW、SD、蓝十字和伊仕5种RDTs检测间日疟原虫的灵敏度分别为85.71%、88.57%、82.86%、88.57%和91.43%,且两两间的差异均无统计学意义(均P>0.05);5种RDTs检测间日疟原虫的特异度分别为100.00%、100.00%、100.00%、100.00%和94.74%。万孚、BinaxNOW和SD 3种RDTs检测卵形疟原虫的灵敏度分别为75.70%、48.60%和1.87%,两两间的差异均有统计学意义(均P<0.01);3种RDTs检测卵形疟原虫的特异度均为100.00%。万孚、BinaxNOW和SD 3种RDTs检测Po-c和Po-w两种卵形疟亚型的灵敏度差异均无统计学意义(均P>0.05),3种RDTs对不同非洲区域卵形疟原虫检测灵敏度的差异亦均无统计学意义(均P>0.05)。结论万孚、BinaxNOW、SD、蓝十字和伊仕5种RDTs检测间日疟原虫的效果均较理想,除万孚检测卵形疟原虫的灵敏度相对较高外,暂未发现卵形疟亚型和感染来源是影响RDTs检测效果的因素。 展开更多
关键词 疟疾快速诊断试剂盒(RDTs) 间日疟原虫 卵形疟原虫 灵敏度 特异度 影响因素
原文传递
Feasibility of Using Two versus Three Rapid Tests for HIV Diagnosis in India: Analysis of Public Health Program Data
12
作者 Varsha Kale Archana Beri +5 位作者 Madhuri Thakar Veenita Sinha Dar Shilpa Bembalkar Naresh Goel Arun Risbud Ramesh Paranjape 《World Journal of AIDS》 2017年第1期16-22,共7页
Under India’s National AIDS Control Program (NACP), WHO recommended strategy of using three rapid tests is adopted for diagnosis of HIV in an asymptomatic individual. Since the NACP has a stringent kit evaluation pro... Under India’s National AIDS Control Program (NACP), WHO recommended strategy of using three rapid tests is adopted for diagnosis of HIV in an asymptomatic individual. Since the NACP has a stringent kit evaluation procedure and due to the availability of newer third generation Rapid Diagnostic Tests (RDTs) it may be possible to adapt two test strategy for HIV diagnosis instead of the recommended three test strategy. The authors reviewed programmatic data on HIV testing to explore whether use of two rapid tests for HIV diagnosis as against three tests could be a feasible approach without compromising the quality and readability of testing. Data on the HIV diagnosis performed on serum specimens collected for the period of one year (2011-12) from 82 Integrated Testing and Counselling Centers (ICTCs) or Prevention of Parent to Child Transmission Centers (PPTCTs) associated with State reference Laboratories (SRLs) was analysed. Out of 654258 results that were analysed 25168 (3.84%) specimens were positives. It was observed that both two and three test algorithms provided similar results for majority (>99%) of the HIV positive specimens. Discordance was observed in labelling of specimen with inconclusive status (N = 21), however the true status of these samples could not be obtained. The analysis indicated that the use of two test algorithm will have programmatic benefits in terms of reduced financial burden to the programme and ease of procurement, shipment and storage before and after distribution without comprising the quality of the testing. The prospective study would confirm this observation. 展开更多
关键词 HIV testing TWO test Strategy rapid diagnostic tests (RDT) National AIDS Control PROGRAM (NACP)
下载PDF
温州首例输入性卵形疟病例的诊断分析 被引量:13
13
作者 张孝和 倪庆翔 +6 位作者 陈祎 姚立农 陆巧绎 余向华 朱善冰 车志教 潘琼娇 《中国寄生虫学与寄生虫病杂志》 CAS CSCD 北大核心 2013年第5期380-381,共2页
温州首次发现1例输入性卵形疟病例,该患者曾在非洲刚果人民共和国务工2年。回国后3个月余后,出现发热等症状,经外周血涂片镜检和PCR检测诊断为卵形疟。随后给予"氯喹+伯氨喹"8日疗法治疗后,症状好转。
关键词 卵形疟 输入病例 巢式PCR 快速检测试剂
下载PDF
快速诊断试剂盒在疟疾诊断中的应用效果 被引量:10
14
作者 张勇 宋维胜 +1 位作者 张西才 张金何 《热带病与寄生虫学》 2014年第3期152-154,共3页
目的探讨疟疾快速诊断试剂盒临床应用效果,为临床应用提供参考。方法快速诊断试剂盒与镜检法对103例疟疾、疑似疟疾进行检测对比分析。结果镜检疟原虫阳性3例(Pf11例、Pv10例、Pm和Po各1例),阳性率22.33%;快速诊断试剂盒检测疟原虫阳性2... 目的探讨疟疾快速诊断试剂盒临床应用效果,为临床应用提供参考。方法快速诊断试剂盒与镜检法对103例疟疾、疑似疟疾进行检测对比分析。结果镜检疟原虫阳性3例(Pf11例、Pv10例、Pm和Po各1例),阳性率22.33%;快速诊断试剂盒检测疟原虫阳性22例(Pf11例、Pv 10例、Pm 1例),阳性率21.36%,卵形疟未检出。两方法检出阳性率无统计学意义(x^2=0.33,P>0.05)。该试剂的总灵敏性95.65%,总特异性97.50%,阳性预测值91.67%,阴性预测值98.73%,漏检率4.35%,误诊率2.50%。结论疟疾快速诊断试剂盒具有良好的疟疾诊断效果和简便、快速等优点,非常适合镜检技术和条件不足的基层医疗、预防机构开展疟疾检测。 展开更多
关键词 疟疾 快速诊断试剂盒 镜检法
下载PDF
全球消除疟疾的生物学挑战Ⅱ疟疾快速诊断试纸条靶标Pfhrp/3基因缺失 被引量:1
15
作者 徐岁 唐建霞 《中国血吸虫病防治杂志》 CAS CSCD 北大核心 2024年第3期239-242,258,共5页
全球疟疾流行依然严峻,疟疾快速诊断试纸条(rapid diagnostic test,RDT)操作简便、检测快速、结果准确,已成为当前疟疾防控中最重要和最广泛使用的诊断工具。但RDT靶标恶性疟原虫富组氨酸蛋白2/3(Plasmodium falciparum histidine-rich ... 全球疟疾流行依然严峻,疟疾快速诊断试纸条(rapid diagnostic test,RDT)操作简便、检测快速、结果准确,已成为当前疟疾防控中最重要和最广泛使用的诊断工具。但RDT靶标恶性疟原虫富组氨酸蛋白2/3(Plasmodium falciparum histidine-rich protein 2/3,Pfhrp2/3)基因缺失可导致RDT产生假阴性检测结果,被WHO列为全球消除疟疾的四大生物学挑战之一。本文通过回顾RDT在全球疟疾诊断中的应用,分析Pfhrp2/3基因缺失带来的威胁与挑战、提出Pfhrp2/3基因缺失的监测方法、总结RDT检测阴性的原因与对策,为巩固我国消除疟疾成果、助力全球消除疟疾提供参考。 展开更多
关键词 疟疾 消除 快速诊断试纸条 富组氨酸蛋白 基因缺失
原文传递
脓毒症细菌快速诊断检测的研究现状与展望 被引量:7
16
作者 陈意飞 刘励军 《中国急救医学》 CAS CSCD 北大核心 2020年第2期170-174,共5页
脓毒症是复杂的病理生理状态,是当今危及患者生命的主要原因之一.脓毒症与细菌感染密切相关,早期诊断、合理治疗能有效减少患者病死率.细菌检验方法包括传统方法如细菌培养、分子生物学核酸扩增、质谱、基因芯片、生物传感器等.尽管诊... 脓毒症是复杂的病理生理状态,是当今危及患者生命的主要原因之一.脓毒症与细菌感染密切相关,早期诊断、合理治疗能有效减少患者病死率.细菌检验方法包括传统方法如细菌培养、分子生物学核酸扩增、质谱、基因芯片、生物传感器等.尽管诊断实验方法多样,病原学实验室检测仍不能满足临床早期诊断的需求,快速检测仍是困扰临床工作的一大难题.本文拟对实验方法学做一简要综述,为临床工作诊疗提供参考,为探索细菌学快速检测提供思路. 展开更多
关键词 脓毒症 细菌 快速诊断检测 分子生物学
下载PDF
我国疟原虫PCR常用检测技术研究进展 被引量:6
17
作者 王星 周红宁 《中国病原生物学杂志》 CSCD 北大核心 2018年第3期318-321,共4页
疟疾是由疟原虫经按蚊叮咬传播的寄生虫病,属全球关注的重要传染病之一。近年来,随着我国消除疟疾工作开展,疟疾本地感染病例得到有效控制,但输入性病例仍不断增加,采取快速准确诊断技术及时发现病例,对遏制疟疾的传播具有重要的意义。... 疟疾是由疟原虫经按蚊叮咬传播的寄生虫病,属全球关注的重要传染病之一。近年来,随着我国消除疟疾工作开展,疟疾本地感染病例得到有效控制,但输入性病例仍不断增加,采取快速准确诊断技术及时发现病例,对遏制疟疾的传播具有重要的意义。我国目前常用的疟疾诊断方法主要有显微镜镜检技术、血清学快速诊断检测和PCR检测技术。显微镜镜检技术虽然操作方法简单,便于现场使用,但对于低原虫密度和使用过抗疟药物等患者较容易漏诊或误诊;血清学快速诊断检测技术操作简单、快速,但未能对疟原虫进行分型和混合感染诊断;PCR技术检测疟原虫具有较高的敏感性和特异性,特别是较容易检测出低密度疟原虫。为此,本文就我国PCR检测疟原虫技术研究进展作一综述。 展开更多
关键词 疟原虫 快速诊断技术 显微镜镜检技术 PCR检测技术 综述
原文传递
免疫荧光分析法在快速诊断A、B型流感病毒中的临床应用 被引量:6
18
作者 杨静红 韩慧超 詹伟 《国际检验医学杂志》 CAS 2014年第11期1476-1477,1481,共3页
目的探讨Sofia Influenza A+B FIA检测系统在快速诊断A、B型流感病毒中的临床应用价值。方法获取临床168例流感患儿的鼻咽拭子样本,分别通过Sofia Influenza A+B FIA检测系统和胶体金免疫层析(GICA)法分别进行A、B型流感病毒检测,并通... 目的探讨Sofia Influenza A+B FIA检测系统在快速诊断A、B型流感病毒中的临床应用价值。方法获取临床168例流感患儿的鼻咽拭子样本,分别通过Sofia Influenza A+B FIA检测系统和胶体金免疫层析(GICA)法分别进行A、B型流感病毒检测,并通过逆转录聚合酶链反应(RT-PCR)进行验证。结果 Sofia Influenza A+B FIA检测系统的阳性检出率为17.86%(30/168),高于GICA法;同时,与RT-PCR相比,对A型流感病毒和B型流感病毒的灵敏度分别达到83.3%和71.4%,特异性均达到100.0%。结论 Sofia Influenza A+B FIA检测系统是一种灵敏度和特异性均较高,能够快速检测A、B型流感病毒的方法。 展开更多
关键词 流感病毒 快速诊断 免疫荧光分析 聚合酶链反应
下载PDF
Study of Malaria in Patients Operated on at the Reference Health Center of Commune I Bamako
19
作者 Tounkara Cheickna Samaké Hamidou +5 位作者 Koné Abdoulaye Maiga Boubacar Diarra Yaya Kayentao Kassoum Dolo Amadou Diallo Mouctar 《Surgical Science》 2023年第9期598-607,共10页
Malaria is a febrile and hemolyzing erythrocytopathy due to the development and multiplication of one or more of the five plasmodial species dependent on humans: Plasmodium falciparum, P. malariae, P. ovale, P. vivax ... Malaria is a febrile and hemolyzing erythrocytopathy due to the development and multiplication of one or more of the five plasmodial species dependent on humans: Plasmodium falciparum, P. malariae, P. ovale, P. vivax and P. knowlesi. These parasites are inoculated into humans by the infective bite of a female mosquito, female anopheles of the genus Anopheles, during a blood meal. The study aimed to: determine the frequency of fever due to malaria after surgery;describe malaria symptomatology and clinical evolution after surgical intervention;determine the average length of hospital stay for operated patients with malaria;evaluate the average cost of malaria treatment. This was a prospective study which involved 110 operated patients, which took place over a period of 12 months from March 2017 to February 2018 in the general surgery department at the Reference Health Center of commune I of the Bamako district. The frequency of malaria was 11.82% before the intervention and 3.64% after the intervention, with an average age of 29.80 years;extremes of 2 years and 76 years and a sex ratio of 1.5 in favor of the male sex. The main clinical signs were fever (38.18%), headache (20.91%) and vomiting (36.36%) and physical asthenia (18.18%). Diagnosed and treated early, malaria progressed favorably. The outcome was simple for all our patients and we did not record any deaths. The cost of treatment was borne by the patients and/or their families. The average cost of treatment was 7915 CFA francs, significantly below the Malian minimum wage which is around 30,000 FCFA. The implementation of preventive measures is necessary to reduce the importance of malaria in hospitals: staff awareness, indoor spraying, use of impregnated mosquito nets. 展开更多
关键词 MALARIA PLASMODIUM Surgery FEVER Thick Gout rapid diagnostic test
下载PDF
福建省南平市一例输入性卵形疟的诊断 被引量:3
20
作者 张芝平 张聪慧 +3 位作者 卓鸣莺 林耀莹 魏惠正 朱淮民 《中国寄生虫学与寄生虫病杂志》 CAS CSCD 北大核心 2015年第1期72-74,共3页
对1例误诊为间日疟的输入性病例进行复核,收集患者流行病学资料和血样,进行镜检、快速疟疾诊断试纸条检测(RDT)和巢式PCR检测,证实该输入性疟疾患者为南平市首例卵形疟病例。
关键词 卵形疟 输入性病例 镜检 快速诊断检测 巢式PCR
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部