With soaring work frequency and decreasing feature sizes, VLSI circuits with RLC parasitic components are more like analog circuits and should be carefully analyzed in physical design. However, the number of extracted...With soaring work frequency and decreasing feature sizes, VLSI circuits with RLC parasitic components are more like analog circuits and should be carefully analyzed in physical design. However, the number of extracted RLC components is typically too large to be analyzed efficiently by using present analog circuit simulators like SPICE. In order to speedup the simulations without error penalty, this paper proposes a novel methodology to compress the time-descritized circuits resulted from numerical integration approximation at every time step. The main contribution of the methodology is the efficient structure-level compression of DC circuits containing many current sources, which is an important complement to present circuit analysis theory. The methodology consists of the following parts: 1) An approach is proposed to delete all intermediate nodes of RL branches. 2) An efficient approach is proposed to compress and back-solve parallel and serial branches so that it is error-free and of linear complexity to analyze circuits of tree topology. 3) The Y to πtransformation method is used to error-free reduce and back-solve the intermediate nodes of ladder circuits with the linear complexity. Thus, the whole simulation method is very accurate and of linear complexity to analyze circuits of chain topology. Based on the methodology, we propose several novel algorithms for efficiently solving RLC-model transient power/ground (P/G) networks. Among them, EQU-ADI algorithm of linear-complexity is proposed to solve RLC P/G networks with mesh-tree or mesh-chain topologies. Experimental results show that the proposed method is at least two orders of magnitude faster than SPICE while it can scale linearly in both time- and memory-complexity to solve very large P/G networks.展开更多
Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is propo...Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time.展开更多
针对3GPP最新发布的LTE(long term evolution)Release 8标准,研究了LTE空中接口协议栈无线链路控制(radio link control,RLC)的子层确认(acknowledged mode,AM)传输模式的设计与实现机制。主要介绍了LTE无线接入网空中接口协议栈的结构...针对3GPP最新发布的LTE(long term evolution)Release 8标准,研究了LTE空中接口协议栈无线链路控制(radio link control,RLC)的子层确认(acknowledged mode,AM)传输模式的设计与实现机制。主要介绍了LTE无线接入网空中接口协议栈的结构,详细阐述了空中接口协议栈中RLC的AM数据传输模式的运行原理,最后根据协议设计了一种具体在协议栈软件中实现AM传输模式的方法。展开更多
The authors analyze a piezoelectric energy harvester as an electro-mechanically coupled system. The energy harvester consists of a piezoelectric bimorph with a concentrated mass attached at one end, called the harvest...The authors analyze a piezoelectric energy harvester as an electro-mechanically coupled system. The energy harvester consists of a piezoelectric bimorph with a concentrated mass attached at one end, called the harvesting structure, an electric circuit for energy storage, and a rectifier that converts the AC output of the harvesting structure into a DC input for the storage circuit. The piezoelectric bimorph is assumed to be driven into flexural vibration by an ambient acoustic source to convert the mechanical energies into electric energies. The analysis indicates that the performance of this harvester, measured by the power density, is characterized by three important non-dimensional parameters, i.e., the non-dimensional inductance of the storage circuit, the non-dimensional aspect ratio (length/thickness) and the non-dimensional end mass of the harvesting structure. The numerical results show that: (1) the power density can be optimized by varying the non-dimensional inductance for each fixed non-dimensional aspect ratio with a fixed non-dimensional end mass; and (2) for a fixed non-dimensional inductance, the power density is maximized if the non-dimensional aspect ratio and the non-dimensional end mass are so chosen that the harvesting structure, consisting of both the piezoelectric bimorph and the end mass attached, resonates at the frequency of the ambient acoustic source.展开更多
A robust adaptive repetitive learning control method is proposed for a class of time-varying nonlinear systems. Nussbaum-gain method is incorporated into the control design to counteract the lack of a priori knowledge...A robust adaptive repetitive learning control method is proposed for a class of time-varying nonlinear systems. Nussbaum-gain method is incorporated into the control design to counteract the lack of a priori knowledge of the control direction which determines the motion direction of the system under any input. It is shown that the system state could converge to the desired trajectory asymptotically along the iteration axis through repetitive learning. Simulation is carried out to show the validity of the proposed control method.展开更多
This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly f...This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.60476014)the State"973"Key Basic Research Program(Grant No.2005CB321604)the UC Senate Research Fund.
文摘With soaring work frequency and decreasing feature sizes, VLSI circuits with RLC parasitic components are more like analog circuits and should be carefully analyzed in physical design. However, the number of extracted RLC components is typically too large to be analyzed efficiently by using present analog circuit simulators like SPICE. In order to speedup the simulations without error penalty, this paper proposes a novel methodology to compress the time-descritized circuits resulted from numerical integration approximation at every time step. The main contribution of the methodology is the efficient structure-level compression of DC circuits containing many current sources, which is an important complement to present circuit analysis theory. The methodology consists of the following parts: 1) An approach is proposed to delete all intermediate nodes of RL branches. 2) An efficient approach is proposed to compress and back-solve parallel and serial branches so that it is error-free and of linear complexity to analyze circuits of tree topology. 3) The Y to πtransformation method is used to error-free reduce and back-solve the intermediate nodes of ladder circuits with the linear complexity. Thus, the whole simulation method is very accurate and of linear complexity to analyze circuits of chain topology. Based on the methodology, we propose several novel algorithms for efficiently solving RLC-model transient power/ground (P/G) networks. Among them, EQU-ADI algorithm of linear-complexity is proposed to solve RLC P/G networks with mesh-tree or mesh-chain topologies. Experimental results show that the proposed method is at least two orders of magnitude faster than SPICE while it can scale linearly in both time- and memory-complexity to solve very large P/G networks.
基金Project supported by the Natural Science Foundation of Heze University of Shandong Province, China (Grant No XY05WL01), the University Experimental Technology Foundation of Shandong Province, China (Grant No S04W138), the Natural Science Foundation of Shandong Province, China (Grant No Y2004A09) and the National Natural Science Foundation of China (Grant No 10574060).
文摘Based on the scheme of damped harmonic oscillator quantization and thermo-field dynamics (TFD), the quantization of mesoscopic damped double resonance RLC circuit with mutual capacitance-inductance coupling is proposed. The quantum fluctuations of charge and current of each loop in a squeezed vacuum state are studied in the thermal excitation case. It is shown that the fluctuations not only depend on circuit inherent parameters, but also rely on excitation quantum number and squeezing parameter. Moreover, due to the finite environmental temperature and damped resistance, the fluctuations increase with the temperature rising, and decay with time.
文摘针对3GPP最新发布的LTE(long term evolution)Release 8标准,研究了LTE空中接口协议栈无线链路控制(radio link control,RLC)的子层确认(acknowledged mode,AM)传输模式的设计与实现机制。主要介绍了LTE无线接入网空中接口协议栈的结构,详细阐述了空中接口协议栈中RLC的AM数据传输模式的运行原理,最后根据协议设计了一种具体在协议栈软件中实现AM传输模式的方法。
基金Project supported by the U.S.Navy's Metrology R&D Program,the US Naval Surface Warfare Center's Measurement Science Department,AEPTEC Microsystems Inc.,and the University of California,MICRO Program.
文摘The authors analyze a piezoelectric energy harvester as an electro-mechanically coupled system. The energy harvester consists of a piezoelectric bimorph with a concentrated mass attached at one end, called the harvesting structure, an electric circuit for energy storage, and a rectifier that converts the AC output of the harvesting structure into a DC input for the storage circuit. The piezoelectric bimorph is assumed to be driven into flexural vibration by an ambient acoustic source to convert the mechanical energies into electric energies. The analysis indicates that the performance of this harvester, measured by the power density, is characterized by three important non-dimensional parameters, i.e., the non-dimensional inductance of the storage circuit, the non-dimensional aspect ratio (length/thickness) and the non-dimensional end mass of the harvesting structure. The numerical results show that: (1) the power density can be optimized by varying the non-dimensional inductance for each fixed non-dimensional aspect ratio with a fixed non-dimensional end mass; and (2) for a fixed non-dimensional inductance, the power density is maximized if the non-dimensional aspect ratio and the non-dimensional end mass are so chosen that the harvesting structure, consisting of both the piezoelectric bimorph and the end mass attached, resonates at the frequency of the ambient acoustic source.
基金supported by the National Basic Research Program of China (No. 2012CB316400)the National Science Foundation of China (Nos.60974135, 60525316, 61171034)the Zhejiang Provincial Natural Science Foundation of China (No. R1110443)
文摘A robust adaptive repetitive learning control method is proposed for a class of time-varying nonlinear systems. Nussbaum-gain method is incorporated into the control design to counteract the lack of a priori knowledge of the control direction which determines the motion direction of the system under any input. It is shown that the system state could converge to the desired trajectory asymptotically along the iteration axis through repetitive learning. Simulation is carried out to show the validity of the proposed control method.
文摘This article presents an extensive examination and modeling of Capacitor Coupled Substations (CCS), noting some of their inherent constraints. The underlying implementation of a CCS is to supply electricity directly from high-voltage (HV) transmission lines to low-voltage (LV) consumers through coupling capacitors and is said to be cost-effective as compared to conventional distribution networks. However, the functionality of such substations is susceptible to various transient phenomena, including ferroresonance and overvoltage occurrences. To address these challenges, the study uses simulations to evaluate the effectiveness of conventional resistor-inductor-capacitor (RLC) filter in mitigating hazardous overvoltage resulting from transients. The proposed methodology entails using standard RLC filter to suppress transients and its associated overvoltage risks. Through a series of MATLAB/Simulink simulations, the research emphasizes the practical effectiveness of this technique. The study examines the impact of transients under varied operational scenarios, including no-load switching conditions, temporary short-circuits, and load on/off events. The primary aim of the article is to assess the viability of using an established technology to manage system instabilities upon the energization of a CCS under no-load circumstances or in case of a short-circuit fault occurring on the primary side of the CCS distribution transformer. The findings underscore the effectiveness of conventional RLC filters in suppressing transients induced by the CCS no-load switching.