期刊文献+
共找到374篇文章
< 1 2 19 >
每页显示 20 50 100
Physical Simulation of New Desulphurization Technology Using Pulsed and Rotary Stirring-Injection 被引量:17
1
作者 WU Wei HU Yan-bin LIU Liu DING Yong-liang 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2008年第1期15-18,共4页
The contrast experiment of different stirring modes,which includes a new type of stirring-injection with the method of pulse and rotation,and the initial one-way stirring method,is done through physical simulation in ... The contrast experiment of different stirring modes,which includes a new type of stirring-injection with the method of pulse and rotation,and the initial one-way stirring method,is done through physical simulation in the laboratory.The stirring methods of pulse and rotation are of two kinds.One is pulsed and rotary stirrer with positive and opposite directions.The other is pulsed and rotary stirrer with rotation-stop-rotation.The results show that the stirring mode of pulse and rotation has better effects than the one-way stirring method.The specific effects are that the mixing time of the melting bath is apparently shortened,the number of grains involved in the liquid surface is increased,and the residence time of air bubble in water is doubled. 展开更多
关键词 hot metal DESULPHURIZATION injection physical simulation pulse ROTATION
原文传递
基极注入强电磁脉冲对双极型晶体管的作用 被引量:14
2
作者 陈曦 杜正伟 龚克 《强激光与粒子束》 EI CAS CSCD 北大核心 2007年第3期449-452,共4页
空间电磁脉冲注入硅双极型晶体管后可能会导致晶体管烧毁。借助2维数值仿真和理论分析研究了基极注入短电磁脉冲对双极型晶体管的作用,得出结论:晶体管的热斑位于基极边缘,由于该点既是电场峰所在,又是电流最密集之处,热量产生集中,因... 空间电磁脉冲注入硅双极型晶体管后可能会导致晶体管烧毁。借助2维数值仿真和理论分析研究了基极注入短电磁脉冲对双极型晶体管的作用,得出结论:晶体管的热斑位于基极边缘,由于该点既是电场峰所在,又是电流最密集之处,热量产生集中,因此基极注入脉冲使晶体管烧毁所需的能量比其它两电极注入要少;在基极注入短脉冲作用下,晶体管烧毁所需能量几乎不随脉冲宽度变化;烧毁所需脉冲功率近似与脉冲宽度成反比。 展开更多
关键词 2维器件数值仿真 电磁脉冲 双极型晶体管 基极注入 烧毁
下载PDF
痰湿壅盛型高血压病患者脉压、血清炎症因子水平表达及痰热清注射液的干预影响 被引量:15
3
作者 王雄 李卫青 《中国中医急症》 2009年第9期1389-1391,1414,共4页
目的监测高血压病患者的脉压(PP),检测血清炎症因子(Hs-CRP、TNF-α、IL-6)水平,探讨其与中医"痰湿壅盛"的关系,并对比痰热清注射液与替米沙坦的干预影响。方法选择高血压病患者60例为观察对象,另选15例健康志愿者为对照组。... 目的监测高血压病患者的脉压(PP),检测血清炎症因子(Hs-CRP、TNF-α、IL-6)水平,探讨其与中医"痰湿壅盛"的关系,并对比痰热清注射液与替米沙坦的干预影响。方法选择高血压病患者60例为观察对象,另选15例健康志愿者为对照组。高血压病患者按中医辨证分为痰湿壅盛型组与非痰湿壅盛型组,分别采用痰热清注射液联合替米沙坦及单用替米沙坦治疗6周;比较两组血压、脉压、动态血压及血清Hs-CRP、TNF-α、IL-6水平的变化。结果与对照组比较,高血压病患者血清Hs-CRP、TNF-α、IL-6水平显著升高;治疗后,痰湿壅盛型组患者血压、脉压均显著降低的同时,血清Hs-CRP、TNF-α、IL-6等炎症因子水平亦显著下降;而非痰湿壅盛组血压、脉压亦明显下降,血清Hs-CRP、TNF-α、IL-6等炎症因子水平亦有变化,但无显著性差异。结论高血压病患者血清Hs-CRP、TNF-α、IL-6水平升高可能与脉压相关;替米沙坦联合痰热清注射液较单用替米沙坦能更明显降低脉压和炎症因子水平。 展开更多
关键词 高血压病 痰浊壅盛型 非痰湿壅盛型 脉压 炎症因子 痰热清注射液
下载PDF
ESD脉冲对集成电路损伤效应的实验研究 被引量:10
4
作者 陈京平 刘尚合 +1 位作者 谭志良 贺其元 《高电压技术》 EI CAS CSCD 北大核心 2007年第3期121-124,共4页
为了研究复杂波形脉冲对集成电路的损伤效应,用改变ESD模拟器放电参数产生的不同的静电放电脉冲对某集成电路芯片进行了注入损伤效应实验。给出了各主要的损伤参数与放电电压的散点图。并借助曲线拟合的方法进行了分析。结果表明:IC... 为了研究复杂波形脉冲对集成电路的损伤效应,用改变ESD模拟器放电参数产生的不同的静电放电脉冲对某集成电路芯片进行了注入损伤效应实验。给出了各主要的损伤参数与放电电压的散点图。并借助曲线拟合的方法进行了分析。结果表明:IC芯片注入通路上的电阻在脉冲波形发生变化时变化不大。电流随放电电压增大;芯片上的峰值功率及峰值能量与放电电压满足P(W)=AUD^B。最后,比较了各脉冲注入下器件的主要参数损伤阈值,得到结论:ESD模拟器放电参数改变对器件损伤阈值大小的影响在1~2倍间。相同参数在不同注入脉冲下的阈值处于同数量级。 展开更多
关键词 静电放电 脉冲 注入 损伤 集成电路 实验研究
下载PDF
真空ns脉冲下环氧复合材料表面电荷特性 被引量:8
5
作者 丁曼 成永红 +5 位作者 阴玮 王增彬 陈玉 周稼斌 孟国栋 吴锴 《高电压技术》 EI CAS CSCD 北大核心 2009年第1期157-162,共6页
表面电荷的产生、运动和积累与真空脉冲沿面闪络息息相关,为了探寻沿面闪络的机理,研究了真空ns脉冲作用下环氧及其复合材料的表面电荷特性。围绕15 ns/1070 ns(脉冲前沿和半高宽)高峰值和165 ns/960 ns低峰值两种脉冲源,针对纯环氧及其... 表面电荷的产生、运动和积累与真空脉冲沿面闪络息息相关,为了探寻沿面闪络的机理,研究了真空ns脉冲作用下环氧及其复合材料的表面电荷特性。围绕15 ns/1070 ns(脉冲前沿和半高宽)高峰值和165 ns/960 ns低峰值两种脉冲源,针对纯环氧及其Al(OH)3和TiO2复合材料,测量了ns级脉冲作用前后的表面电位分布。脉冲作用不闪络时,试样将带有正电荷,闪络后,试样表面积累少量负电荷;纯环氧带电量明显高于其复合材料试样;随脉冲作用次数的增加带电量逐渐增加并最终饱和,阴极电位高于阳极。研究认为:脉冲作用下表面电荷积累受电荷注入、二次电子发射及碰撞电离等多种因素影响。闪络通道形成前,二次电子发射和碰撞电离起主要作用;闪络通道形成后,电荷的中和和注入作用占据主导地位。 展开更多
关键词 表面电荷 沿面闪络 NS脉冲 环氧复合材料 电荷注入 二次电子发射 碰撞电离
下载PDF
右美托咪定复合罗哌卡因程控硬膜外间歇脉冲注入应用于分娩镇痛的临床研究 被引量:8
6
作者 唐勇 潘雪琳 刘庆 《中国计划生育和妇产科》 2019年第8期53-56,61,共5页
目的探讨右美托咪定复合罗哌卡因采用程控硬膜外间歇脉冲注入应用于分娩镇痛的镇痛效果及对产妇和新生儿的影响。方法选择2017年7~12月于四川锦欣妇女儿童医院要求实施分娩镇痛的足月初产妇80例,采用随机数字表法分为两组,右美托咪定组(... 目的探讨右美托咪定复合罗哌卡因采用程控硬膜外间歇脉冲注入应用于分娩镇痛的镇痛效果及对产妇和新生儿的影响。方法选择2017年7~12月于四川锦欣妇女儿童医院要求实施分娩镇痛的足月初产妇80例,采用随机数字表法分为两组,右美托咪定组(D组):0. 5 ug/m L右美托咪定+0. 09%罗哌卡因;舒芬太尼组(S组):0. 5 ug/m L舒芬太尼+0. 09%罗哌卡因,每组40例。宫口开至2 cm时,实施持续性硬膜外镇痛,连接脉冲式自控镇痛泵。记录两组产妇镇痛实施前(T_0)、镇痛后10 min(T_1)、30 min(T_2)、宫口开全时(T_3)、胎儿娩出即刻(T4)的生命体征、VAS评分、Bromage评分、Ramsay镇静评分。记录妊娠结局、PCA次数、用药总量、产程、出血量、新生儿Apgar评分以及不良反应。结果两组分娩镇痛后都取得良好的效果。D组产妇在T_1时点的VAS评分低于S组(P <0. 05),在T_1、T_2时点的Ramsay评分明显高于S组(P <0. 05)。两组产妇妊娠结局、PCA次数、用药总量、第一、二产程时长、出血量、新生儿Apgar评分比较,差异均无统计学意义(P> 0. 05)。D组皮肤瘙痒发生率明显低于S组(P <0. 05)。结论右美托咪定复合罗哌卡因程控硬膜外间歇脉冲注入应用于分娩镇痛起效更快,镇痛镇静效果好,对母婴无明显不良反应。 展开更多
关键词 右美托咪定 罗哌卡因 脉冲注入 分娩镇痛
原文传递
10 kV配电变压器高空电磁脉冲效应实验研究 被引量:3
7
作者 陈宇浩 王宗扬 +3 位作者 王禹博 周熠 景龑 谢彦召 《高电压技术》 EI CAS CSCD 北大核心 2023年第7期3119-3124,共6页
高空电磁脉冲具有场强幅值高、分布范围广、频谱范围宽等特点,可以通过广域分布的配电线缆耦合进入配电变压器,较大的电流变化率会在绕组中感应一定的匝间电压对变压器匝间甚至相间绝缘可能会造成威胁。因此,针对典型10 kV油浸式配电变... 高空电磁脉冲具有场强幅值高、分布范围广、频谱范围宽等特点,可以通过广域分布的配电线缆耦合进入配电变压器,较大的电流变化率会在绕组中感应一定的匝间电压对变压器匝间甚至相间绝缘可能会造成威胁。因此,针对典型10 kV油浸式配电变压器和干式配电变压器开展电磁脉冲效应实验,对比分析其效应现象与阈值规律。搭建了可用于开展10 kV配电变压器运行状态电磁脉冲效应实验的研究平台,主要由10 kV真型配电系统和电磁脉冲注入系统两部分组成,可向10 kV配电变压器共模注入三相纳秒级脉冲电流。基于该实验平台,分别针对所研究的10 kV油浸式配电变压器和干式配电变压器开展系统不带电和系统带电运行状态下的对比效应实验并获取实验数据。结果表明,在该实验脉冲注入电流的幅值范围内,即三相脉冲注入电流最大峰值约为500 A,油浸式变压器和干式变压器均具有一定的抗电磁脉冲能力,实验中未发生故障效应。 展开更多
关键词 高空电磁脉冲 脉冲注入 真型配电系统 配电变压器 运行状态 易损性
下载PDF
强电磁脉冲对硅微惯性传感器的损伤效应研究 被引量:7
8
作者 沈杰 潘绪超 +4 位作者 方中 何勇 陈鸿 张江南 史云雷 《兵工学报》 EI CAS CSCD 北大核心 2020年第6期1157-1164,共8页
为研究强电磁脉冲对单兵外骨骼助力系统上硅微惯性传感器的电磁损伤效应,通过理论计算和试验分析相结合的方法,对硅微惯性传感器的电磁损伤阈值、电磁易损器件和损伤模式开展研究。采用Agrawal传输线理论模型和格林函数法,计算硅微惯性... 为研究强电磁脉冲对单兵外骨骼助力系统上硅微惯性传感器的电磁损伤效应,通过理论计算和试验分析相结合的方法,对硅微惯性传感器的电磁损伤阈值、电磁易损器件和损伤模式开展研究。采用Agrawal传输线理论模型和格林函数法,计算硅微惯性传感器在电磁脉冲环境中由直连线缆耦合并传导至信号传输端口的强电脉冲,并开展信号传输端口的强电脉冲注入试验和传感器损伤模式分析。研究结果表明:硅微惯性传感器的强电脉冲损伤阈值为780 V,电磁易损元器件为前端电容和信号放大器,其主要损伤模式为电容的高电压击穿和放大器的大电流烧毁。 展开更多
关键词 电磁脉冲 微惯性传感器 注入试验 损伤模式
下载PDF
合金滤料与化纤滤料清灰性能对比实验研究 被引量:7
9
作者 郑晓盼 《环境工程》 CAS CSCD 北大核心 2018年第1期92-96,107,共6页
采用典型的合金滤料和化纤滤料进行脉冲喷吹清灰性能对比实验研究,选取过滤精度接近的合金滤料和化纤滤料作为研究对象。通过全尺寸脉冲喷吹实验台,对由合金和化纤两种滤料制成的相同规格长滤袋进行脉冲喷吹实验,测量滤袋侧壁的压力峰... 采用典型的合金滤料和化纤滤料进行脉冲喷吹清灰性能对比实验研究,选取过滤精度接近的合金滤料和化纤滤料作为研究对象。通过全尺寸脉冲喷吹实验台,对由合金和化纤两种滤料制成的相同规格长滤袋进行脉冲喷吹实验,测量滤袋侧壁的压力峰值及其分布、正反向加速度峰值及其分布;同时,采用VDI过滤性能实验平台对滤料进行压降、粉尘剥离率等参数的测试。最后,综合分析对比合金滤料与化纤滤料的脉冲喷吹清灰效果与性能,探索合金滤料的脉冲喷吹清灰性能评价方法。 展开更多
关键词 合金滤料 化纤滤料 脉冲喷吹 VDI 清灰性能
原文传递
直流固态继电器电磁脉冲失效模式实验研究 被引量:7
10
作者 孙蓓云 陈向跃 +1 位作者 翟爱斌 毛从光 《强激光与粒子束》 EI CAS CSCD 北大核心 2009年第12期1913-1915,共3页
采用电流注入法对某型直流固态继电器输入端与输出端的电磁脉冲损伤机制及失效模式进行了实验研究,结果表明:输入端注入电磁脉冲信号时,输出端会产生误动作,并可造成输入电路中三极管BE节产生短路损伤,导致输入端施加控制信号时输出端... 采用电流注入法对某型直流固态继电器输入端与输出端的电磁脉冲损伤机制及失效模式进行了实验研究,结果表明:输入端注入电磁脉冲信号时,输出端会产生误动作,并可造成输入电路中三极管BE节产生短路损伤,导致输入端施加控制信号时输出端无法导通;输出端注入电磁脉冲信号时,可造成输出电路中MOSFET管的栅极和漏极产生短路损伤,导致输出端短路。 展开更多
关键词 固态继电器 电磁脉冲 电流注入 失效模式
下载PDF
Progress of the injection laser system of SG-Ⅱ 被引量:5
11
作者 Wei Fan Youen Jiang +16 位作者 Jiangfeng Wang Xiaochao Wang Dajie Huang Xinghua Lu Hui Wei Guoyang Li Xue Pan Zhi Qiao Chao Wang He Cheng Peng Zhang Wenfa Huang Zhuli Xiao Shengjia Zhang Xuechun Li Jianqiang Zhu Zunqi Lin 《High Power Laser Science and Engineering》 SCIE CAS CSCD 2018年第2期154-180,共27页
A high power laser system was used to drive the ignition of inertial confinement fusion(ICF), of which the high energy,the uniform focal spot, the accurate laser waveform, and the synchronization between the laser bea... A high power laser system was used to drive the ignition of inertial confinement fusion(ICF), of which the high energy,the uniform focal spot, the accurate laser waveform, and the synchronization between the laser beams are key parameters.To accomplish this, global laser characteristics control should be assured, which was the main purpose of the injection laser system. In this paper, the key technological progress involved in the improvement of the performance of the injection laser of SG-II is reported, including frequency domain control, time domain control, near-field spatial shaping, preamplifier technology, and the optical parametric chirped pulse amplification pump source. 展开更多
关键词 AMPLIFIER injection laser pulse shaping spatial shaping SYNCHRONIZATION
原文传递
聚四氟乙烯覆膜滤料滤膜耐喷吹性能研究
12
作者 郑智宏 《产业用纺织品》 2024年第5期21-26,共6页
通过脉冲喷吹试验对比4种聚四氟乙烯(PTFE)覆膜滤料脉冲喷吹前后的膜破损率和透气率,评估覆膜滤料滤膜性能。结果表明:PTFE膜的厚度与微细纤维密度呈正相关,孔径大小与膜厚度呈负相关。在PTFE膜复合到聚苯硫醚(PPS)滤料表面后,厚度较大... 通过脉冲喷吹试验对比4种聚四氟乙烯(PTFE)覆膜滤料脉冲喷吹前后的膜破损率和透气率,评估覆膜滤料滤膜性能。结果表明:PTFE膜的厚度与微细纤维密度呈正相关,孔径大小与膜厚度呈负相关。在PTFE膜复合到聚苯硫醚(PPS)滤料表面后,厚度较大的PTFE膜不容易变形,因此受脉冲喷吹影响较小,具有更长的使用寿命;较薄的PTFE膜容易被拉伸,脉冲喷吹后破损严重,使用寿命较短。并指出,脉冲喷吹试验可用于评估覆膜滤料滤膜的耐久性及可靠性。试验结果可为PTEF膜厚度的选择提供有效参考。 展开更多
关键词 覆膜滤料 聚苯硫醚(PPS)滤料 聚四氟乙烯(PTFE)膜 脉冲喷吹 膜破损率 孔隙 透气率 耐久性
下载PDF
GIS不同耦合方式下注入脉冲的加权IMF局放信号等效性
13
作者 董冰冰 李康 +3 位作者 高常胜 刘贯科 戴喜良 夏云峰 《电力工程技术》 北大核心 2024年第4期95-103,共9页
注入脉冲模拟局放是气体绝缘金属封闭组合电器(gas insulated switchgear,GIS)特高频(ultra high frequency,UHF)局放监测装置功能校验的主要方法,由于现场校验脉冲注入的耦合方式不同,模拟局放与实际局放等效性规律尚不明确,无法保证... 注入脉冲模拟局放是气体绝缘金属封闭组合电器(gas insulated switchgear,GIS)特高频(ultra high frequency,UHF)局放监测装置功能校验的主要方法,由于现场校验脉冲注入的耦合方式不同,模拟局放与实际局放等效性规律尚不明确,无法保证监测装置功能校验的有效性。文中首先建立126 kV GIS典型局放缺陷(尖端、悬浮、绝缘子气泡)和内/外置式脉冲注入UHF局放检测平台,并对UHF信号有效脉冲进行归一化提取;接着提出基于经验模态分解的加权本征模函数(intrinsic mode functions,IMF)信号处理方法,通过计算局放信号欧式距离平均值和最大值表征其等效性;最后与常规信号偏差法进行对比验证。研究表明,相较于常规信号等效性分析方法,加权IMF法可有效解决UHF信号波形局部差异较大的问题;使用内置传感器脉冲注入的模拟局放信号与悬浮局放信号等效性最高,局放信号的欧式距离平均值M_(e)和最大值M_(a)分别为3.82%和10.28%。因此,UHF监测装置功能校验可采用恒定参数注入脉冲代替悬浮缺陷,且模拟局放可优先选择内置UHF传感器注入脉冲。文中研究可为UHF局放监测装置功能校验的脉冲注入方法提供参考。 展开更多
关键词 注入脉冲 局放模拟 经验模态分解 信号等效性分析 本征模函数(IMF) 欧式距离
下载PDF
罗哌卡因联合舒芬太尼硬膜外脉冲式注射在分娩镇痛中的效果
14
作者 蒙占涛 《中外医学研究》 2024年第25期150-154,共5页
目的:观察罗哌卡因联合舒芬太尼硬膜外脉冲式注射在分娩镇痛中的效果。方法:选取2021年1月—2022年12月在天津市职业病防治院拟行顺产的60例产妇纳入研究,按随机数表法分为研究组和对照组,各30例。两组均使用罗哌卡因联合舒芬太尼硬膜... 目的:观察罗哌卡因联合舒芬太尼硬膜外脉冲式注射在分娩镇痛中的效果。方法:选取2021年1月—2022年12月在天津市职业病防治院拟行顺产的60例产妇纳入研究,按随机数表法分为研究组和对照组,各30例。两组均使用罗哌卡因联合舒芬太尼硬膜外镇痛,其中研究组通过脉冲式注射给药,对照组通过连续输注给药。比较两组术中疼痛水平、镇痛泵按压次数、产程、不良反应、新生儿结局、术后运动阻滞情况、术后恢复时间。结果:研究组术中视觉模拟评分(VAS)评分低于对照组,镇痛泵按压次数少于对照组,差异有统计学意义(P<0.05)。两组产程、新生儿结局比较,差异无统计学意义(P>0.05)。研究组术后24 h改良Bromage评分高于对照组,术后首次下床活动时间、排气时间、排便时间短于对照组,差异有统计学意义(P<0.05)。两组住院时间比较,差异无统计学意义(P>0.05);两组不良反应总发生率比较,差异无统计学意义(P>0.05)。结论:罗哌卡因联合舒芬太尼硬膜外脉冲式注射用于分娩镇痛,可获得较好术中镇痛效果,产妇按压镇痛泵次数较少,有助于缩短术后运动阻滞解除时间,促进产后尽快恢复,未明显影响新生儿结局和产后不良反应。 展开更多
关键词 罗哌卡因 舒芬太尼 脉冲式注射 分娩镇痛
下载PDF
卧式短滤筒除尘器脉冲喷吹清灰过程数值分析及机构优化
15
作者 管春宇 阎秋生 《机电工程技术》 2024年第8期205-210,共6页
针对具有更好尺寸适配性的卧式短滤筒除尘器,采用CFD软件对除尘器的脉冲喷吹清灰过程进行了动态数值模拟。通过仿真分析了喷吹过程中滤筒内部的流速和流场压力变化,对比了长短滤筒喷吹过程中压力分布的差别。通过单因素仿真对比分析,得... 针对具有更好尺寸适配性的卧式短滤筒除尘器,采用CFD软件对除尘器的脉冲喷吹清灰过程进行了动态数值模拟。通过仿真分析了喷吹过程中滤筒内部的流速和流场压力变化,对比了长短滤筒喷吹过程中压力分布的差别。通过单因素仿真对比分析,得到喷吹压力为0.5MPa、喷吹距离为180mm时,该除尘器的清灰效果最为理想。此外,合理设置文氏管对清灰效果也起到了显著的作用。针对清灰压力分布不均匀的问题,提出了一种在滤筒开口处设置圆锥形导流板的机构,使喷吹气流在滤筒前部提前扩散,有效提高喷吹气流均匀性。经研究结果显示,确定当导流板圆锥角度为70°时效果最佳。研究成果对于优化卧式短滤筒除尘器的设计和提高其清灰效果具有一定参考价值及指导意义。 展开更多
关键词 滤筒除尘器 短滤筒 脉冲喷吹 数值模拟
下载PDF
卧式三角型滤筒的脉冲喷吹清灰性能
16
作者 谢智宇 林涛 +4 位作者 杨光辉 王云端 林小嘉 陈海焱 林龙沅 《中国粉体技术》 CAS CSCD 2024年第5期146-157,共12页
【目的】为优化卧式三角型滤筒除尘器的清灰性能,探究不同喷吹气流对滤筒内部压力分布的影响,获得不同喷吹孔型式对三角型滤筒的清灰性能的影响规律。【方法】分别采用直管喷吹孔、文氏里管、散射喷嘴、新型曲面诱导引射器共4种喷吹孔... 【目的】为优化卧式三角型滤筒除尘器的清灰性能,探究不同喷吹气流对滤筒内部压力分布的影响,获得不同喷吹孔型式对三角型滤筒的清灰性能的影响规律。【方法】分别采用直管喷吹孔、文氏里管、散射喷嘴、新型曲面诱导引射器共4种喷吹孔型式的诱导引流装置对卧式三角型滤筒开展冷态脉冲实验,以侧壁压强峰值和相对标准偏差作为评价清灰性能的技术指标,分别探讨不同条件下的喷吹射流对滤筒内壁压力分布的影响。【结果】在喷吹压强分别设为0.3、0.4、0.5 MPa的条件下,采用直管、文丘里管、新型曲面诱导引射器时喷吹距离分别设为150、200、250、300、350、400 mm,采用散射喷嘴时喷吹距离分别设为25、50、75、100、125、150、175 mm,则采用直管、文丘里管、散射喷嘴、新型曲面诱导引射器时的平均侧壁压强峰值分别为1037、1758、952、1533 Pa,相对标准偏差分别为0.76、0.58、0.09、0.16;采用新型曲面诱导引射器喷吹孔时,比采用散射喷嘴时的清灰强度高61%,比采用文丘里管时的相对标准偏差小0.47。【结论】新型曲面诱导引射器同时兼顾对侧壁压强峰值和相对标准偏差的要求,在4种喷吹孔型式中清灰性能最佳。 展开更多
关键词 卧式三角型滤筒 脉冲喷吹 清灰性能 喷吹孔
下载PDF
基于单阈值的开关磁阻电机无位置传感器技术 被引量:6
17
作者 罗德荣 李亚雄 +1 位作者 李孟秋 冯垚径 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2017年第2期94-100,共7页
针对位置传感器对开关磁阻电机(Switch Reluctance Motor,SRM)应用范围的限制,研究了一种基于单阈值脉冲注入法的开关磁阻电机无位置传感器控制策略.以三相6/4结构电机为例,讨论在母线电压变化情况下向某一非导通相注入脉冲,通过均值采... 针对位置传感器对开关磁阻电机(Switch Reluctance Motor,SRM)应用范围的限制,研究了一种基于单阈值脉冲注入法的开关磁阻电机无位置传感器控制策略.以三相6/4结构电机为例,讨论在母线电压变化情况下向某一非导通相注入脉冲,通过均值采样方法计算脉冲电流峰值,与预设电流阈值比较实现位置估算.根据相邻阈值的时间间隔计算出电机转速,进一步获得其他相位置信息,并分析了估算位置与实际位置偏差的产生原因.该方法不但降低了脉冲注入带来的负转矩影响,还可实现角度控制,便于电机运行状态的优化.运用所述方法搭建了SRM无位置传感器调速系统的仿真模型,并通过试验证明了其正确性和可行性. 展开更多
关键词 开关磁阻电机 无位置传感器 脉冲注入 均值采样
下载PDF
利用参考电压注入的Buck变换器电感电容估计
18
作者 彭程 陈晨 +2 位作者 姜东升 闵闰 童乔凌 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2024年第5期114-120,共7页
电路的元件参数,尤其是电感和电容值,严重影响着Buck变换器的控制性能。提出了一种参考电压脉冲注入法用于电感和电容的在线估计。为了提高Buck变换器中电感和电容值的估计精度,利用原稳态和新稳态构建满秩状态方程,在线推导算法所需寄... 电路的元件参数,尤其是电感和电容值,严重影响着Buck变换器的控制性能。提出了一种参考电压脉冲注入法用于电感和电容的在线估计。为了提高Buck变换器中电感和电容值的估计精度,利用原稳态和新稳态构建满秩状态方程,在线推导算法所需寄生参数和负载电阻。研究基于电感伏秒特性和电容电荷平衡特性的精确离散时间变换器模型,为元件参数估计奠定了基础。通过给参考电压注入短脉冲信号,并使用PID控制器对电路中的电感电流和输出电压进行调节,建立了用于参数估计的瞬态和新稳态。利用瞬态中采样的电压和电感电流估计电感和电容值,避免了稳态时的收敛问题。基于提出的平均电感电流估计算法,电流采样频率降低至开关频率。最后,在Matlab/Simulink平台上进行了仿真验证,结果表明:即使在考虑实际噪声的情况下,电感和电容值的最大估计误差分别小于2%和4.2%;相较于其他参数估计算法,参考电压脉冲注入方法的引入有效提高了参数辨识的估计精度,有助于Buck变换器系统控制性能的提升。 展开更多
关键词 BUCK变换器 参数估计 脉冲注入 电感 电容
下载PDF
基于全周期电流包络线开关磁阻电机无位置传感器技术 被引量:6
19
作者 张磊 刘闯 韩守义 《电机与控制学报》 EI CSCD 北大核心 2019年第11期109-117,共9页
针对开关磁阻电机在低速运行状况下位置估计困难的问题,依据转子位置信号与电感曲线之间关系,提出一种全周期脉冲电流峰值包络线的无位置传感器技术。导通区域利用固定转波时间的斩波控制方式,非导通区域进行注入高频脉冲,两个区域里分... 针对开关磁阻电机在低速运行状况下位置估计困难的问题,依据转子位置信号与电感曲线之间关系,提出一种全周期脉冲电流峰值包络线的无位置传感器技术。导通区域利用固定转波时间的斩波控制方式,非导通区域进行注入高频脉冲,两个区域里分别检测出脉冲电流的峰值,通过数学拟合得到全周期脉冲电流包络线与电机转子位置角之间的数学模型,再通过简易的逻辑比较模块即可得到电机转子位置信号,再根据转子位置信号之间的夹角估算出电机转速和转子位置角度。所提方法由于三相电流包络线交接点在电感上升和下降过程中,电感变化率大,所以不同脉冲下的电流峰值变化大,从而提高了微处理器处理精度,且不需要预先设置脉冲电流阀值,算法简单,容易实现。最后通过仿真和实验,验证了所提方法的正确性和可行性。 展开更多
关键词 开关磁阻电机 全周期包络线 位置估计 斩波控制 脉冲注入
下载PDF
脉冲式注射给药硬膜外阻滞麻醉分娩镇痛对足月妊娠产妇的影响 被引量:5
20
作者 宫风山 张选强 李晓雯 《中国临床实用医学》 2018年第4期9-13,共5页
目的探讨脉冲式注射给药硬膜外阻滞麻醉分娩镇痛对足月妊娠产妇的影响。方法选取2015年1月至2017年4月运城市中心医院收治的124例足月妊娠产妇,按照随机数表法随机分为恒定注射组与脉冲注射组,每组62例。两组产妇均行硬膜外阻滞麻醉... 目的探讨脉冲式注射给药硬膜外阻滞麻醉分娩镇痛对足月妊娠产妇的影响。方法选取2015年1月至2017年4月运城市中心医院收治的124例足月妊娠产妇,按照随机数表法随机分为恒定注射组与脉冲注射组,每组62例。两组产妇均行硬膜外阻滞麻醉,恒定注射组予以持续恒定注射给药,脉冲注射组予以脉冲式注射给药。观察比较两组产妇的疼痛程度评分(VAS)、分娩方式、产程、血清T细胞亚群变化情况(CD4^+、CD8^+、CD3^+、CD4^+/CD8^)及血清泌乳素水平。结果两组产妇宫口全开时(T1)、胎儿分娩时(T2)的VAS评分均较潜伏期末(T0)低,且脉冲注射组产妇低于恒定注射组产妇,差异有统计学意义(P〈0.05);两组产妇的第一产程、第二产程、第三产程比较,差异无统计学意义(P〉0.05);脉冲注射组产妇和恒定注射组产妇的阴道助产率(14.5%、17.8%)、剖宫产率(1.6%、4.8%)、顺产率(83.9%、77.4%)比较,差异无统计学意义(P〉0.05);T1、T2、产后24h(T3),脉冲注射组产妇的血清泌乳素水平[(186.55±7.28)pg/L、(284.76±108.53)p#L、(301.62±113.24)pg/L]高于恒定注射组产妇[(148.65±8.51)pg/L、(216.45±101.11)pg/L、(287.26±106.41)pg/L],差异有统计学意义(P〈0.05);T3时两组产妇的血清CD4^+/CD8^+、CD4^+、CD3^+水平均低于T1、T2时,且脉冲注射组高于恒定注射组,差异有统计学意义(P〈0.05)。结论脉冲式注射给药硬膜外阻滞麻醉可减轻足月妊娠产妇分娩疼痛,提高血清泌乳素水平,调节T细胞亚群平衡,且在提高顺产率等方面具有重要价值。 展开更多
关键词 脉冲式注射 硬膜外阻滞麻醉 足月妊娠 静脉注射
原文传递
上一页 1 2 19 下一页 到第
使用帮助 返回顶部