With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equi...With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability.展开更多
To investigate thermal protection effects of heat sinking vest with phase-change material (PCM), human thermoregulation model is introduced, and a thermal mathematical model of heat transfer with phase change has be...To investigate thermal protection effects of heat sinking vest with phase-change material (PCM), human thermoregulation model is introduced, and a thermal mathematical model of heat transfer with phase change has been developed with the enthalpy method. The uniform energy equation is constructed for the whole domain, and the equation is implicitly discreted by control volume and finite difference method. Then the enthalpy in each node is solved by using chasing method to calculate the tridiagonal equations, and the inner surface temperature of PCM could be obtained. According to the human thermoregulation model of heat sinking vest, the dynamic temperature distribution and sweat of the body are solved. Calculation results indicate that the change of core temperature matches the experimental result, and the sweat difference is small. This thermal mathematical model of heat transfer with phase change is credible and appropriate. Through comparing the dynamic temperature distribution and sweat of the body wearing heat sinking vest to results of the body not wearing this clothing, it is evident that wearing heat sinking vest can reduce the body heat load significantly.展开更多
This paper presents the principle,properties,advantage and disadvantage,associated problems and trend of laser protection with VO 2 film for infrared detectors in the range of 3~5μm and 8~12μm regions and suggest...This paper presents the principle,properties,advantage and disadvantage,associated problems and trend of laser protection with VO 2 film for infrared detectors in the range of 3~5μm and 8~12μm regions and suggests VO 2 film is a potential protection material for infrared detectors.展开更多
基金supported by the National Natural Science Foundation of China(NO.51877018).
文摘With the rapid development of modern distribution network and the access of distributed generation,the network structure is becoming increasingly complex.Frequent single-phase break faults have seriously affected equipment and personal safety and stable operation of the power system.However,with the development and application of the composite neutral grounding modes,the protection of single-phase break fault is facing new challenges.This paper proposes a protection method of single-phase break fault for distribution network considering the influence of neutral grounding modes.The characteristics of neutral voltage and sequence current are analyzed under normal operation and single-phase break fault with different grounding modes.Following this,the protection criterion based on neutral voltage and sequence current variation is constructed.The protection method of singlephase break fault for distribution network is proposed,which is applicable for various neutral grounding modes.Theoretical analysis and simulation results show that the protection method is less affected by system asymmetry,fault location and load distribution.The method has higher sensitivity,reliability and adaptability.
文摘To investigate thermal protection effects of heat sinking vest with phase-change material (PCM), human thermoregulation model is introduced, and a thermal mathematical model of heat transfer with phase change has been developed with the enthalpy method. The uniform energy equation is constructed for the whole domain, and the equation is implicitly discreted by control volume and finite difference method. Then the enthalpy in each node is solved by using chasing method to calculate the tridiagonal equations, and the inner surface temperature of PCM could be obtained. According to the human thermoregulation model of heat sinking vest, the dynamic temperature distribution and sweat of the body are solved. Calculation results indicate that the change of core temperature matches the experimental result, and the sweat difference is small. This thermal mathematical model of heat transfer with phase change is credible and appropriate. Through comparing the dynamic temperature distribution and sweat of the body wearing heat sinking vest to results of the body not wearing this clothing, it is evident that wearing heat sinking vest can reduce the body heat load significantly.
文摘This paper presents the principle,properties,advantage and disadvantage,associated problems and trend of laser protection with VO 2 film for infrared detectors in the range of 3~5μm and 8~12μm regions and suggests VO 2 film is a potential protection material for infrared detectors.