To provide a safe transportation system in an extremely cold region,evaluation needs to be conducted of the thickness and the volumetric water content of the active layer,as they significantly affect frost heave.The o...To provide a safe transportation system in an extremely cold region,evaluation needs to be conducted of the thickness and the volumetric water content of the active layer,as they significantly affect frost heave.The objective of this study was to evaluate the dielectric constant(κ)of the active layer using ground-penetrating radar(GPR)and a dynamic cone penetrometer(DCP);this evaluation was then used to estimate the thickness and the volumetric water content of the active layer.A field located in midwest Alaska was selected as the study site.A GPR survey and two DCP tests were conducted on the surface of the ground,and the ground temperature was measured.From the GPR survey,travel times of the electromagnetic wave in the active layer were obtained.In addition,the thickness of the active layer was determined by using the dynamic cone penetration index(DCPI)and ground temperature.By using the travel time and travel distance of the electromagnetic wave in the active layer,dielectric constants were calculated as 26.3 and 26.4 for two DCP points.From the mean dielectric constant,the volumetric water content was estimated to be 40%~43%,and the thickness of the active layer was evaluated along the GPR survey line.The spatial-scaled GPR image showed that the thickness of the active layer varied from 520 mm to 700 mm due to the presence of a puddle,which accelerated the heat exchange.The results show that evaluation of the dielectric constant using the GPR survey and the DCP test can be effectively used to estimate the thickness and the volumetric water content of the active layer.展开更多
One of the most critical hardware components of a ground-penetrating radar(GPR)is the antenna system.Important parameters of antennas,such as antenna bandwidth,radiation waveform and cross coupling determine the GPR s...One of the most critical hardware components of a ground-penetrating radar(GPR)is the antenna system.Important parameters of antennas,such as antenna bandwidth,radiation waveform and cross coupling determine the GPR system performance.The modified TEM horn antenna with distributed resistor load is presented in this paper,and the radiation properties of the antenna with the shields and absorbers are studied through the three-dimensional finite-difference time-domain(FDTD)scheme.Simulations show that the direct signal coupled from the transmitter is decreased by means of the shields and absorbers.Therefore,using the antenna in the GPR system can improve the signal-to-clutter ratio and the dynamic range of the system.展开更多
Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. Th...Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. The mark radar images of disturbance of slight, middle, and strong were obtained. The result shows that the radar method can not only determine the position of the concrete pipeline underground, but it can detect the laying quality of pipeline as well.展开更多
基金supported by the National Research Council of Science & Technology (NST) grant by the Korean government (MSIP) (No. CRC-14-02-ETRI)
文摘To provide a safe transportation system in an extremely cold region,evaluation needs to be conducted of the thickness and the volumetric water content of the active layer,as they significantly affect frost heave.The objective of this study was to evaluate the dielectric constant(κ)of the active layer using ground-penetrating radar(GPR)and a dynamic cone penetrometer(DCP);this evaluation was then used to estimate the thickness and the volumetric water content of the active layer.A field located in midwest Alaska was selected as the study site.A GPR survey and two DCP tests were conducted on the surface of the ground,and the ground temperature was measured.From the GPR survey,travel times of the electromagnetic wave in the active layer were obtained.In addition,the thickness of the active layer was determined by using the dynamic cone penetration index(DCPI)and ground temperature.By using the travel time and travel distance of the electromagnetic wave in the active layer,dielectric constants were calculated as 26.3 and 26.4 for two DCP points.From the mean dielectric constant,the volumetric water content was estimated to be 40%~43%,and the thickness of the active layer was evaluated along the GPR survey line.The spatial-scaled GPR image showed that the thickness of the active layer varied from 520 mm to 700 mm due to the presence of a puddle,which accelerated the heat exchange.The results show that evaluation of the dielectric constant using the GPR survey and the DCP test can be effectively used to estimate the thickness and the volumetric water content of the active layer.
基金This work was supported by the National Basic Research Program of China(No.2001AA132020).
文摘One of the most critical hardware components of a ground-penetrating radar(GPR)is the antenna system.Important parameters of antennas,such as antenna bandwidth,radiation waveform and cross coupling determine the GPR system performance.The modified TEM horn antenna with distributed resistor load is presented in this paper,and the radiation properties of the antenna with the shields and absorbers are studied through the three-dimensional finite-difference time-domain(FDTD)scheme.Simulations show that the direct signal coupled from the transmitter is decreased by means of the shields and absorbers.Therefore,using the antenna in the GPR system can improve the signal-to-clutter ratio and the dynamic range of the system.
文摘Ground Penetrating Radar method was used in detecting the flaws of underground pipeline. The GPR layer disturbing image was summarized by using a rational method in fieldwork and the in-door interpretation of data. The mark radar images of disturbance of slight, middle, and strong were obtained. The result shows that the radar method can not only determine the position of the concrete pipeline underground, but it can detect the laying quality of pipeline as well.