Poly brominated biphenyl(PBBs) and poly brominated diphenyl ether(PBDEs) in polymers of electrotechnical products have been extracted with toluene and analyzed by gas chromatography-mass spectrometry (GC-MS).The resul...Poly brominated biphenyl(PBBs) and poly brominated diphenyl ether(PBDEs) in polymers of electrotechnical products have been extracted with toluene and analyzed by gas chromatography-mass spectrometry (GC-MS).The result has more credibility when the nature of the sample was determined by retention time and the proportion of characteristic ions.PBBs and PBDEs were quantified by internal standard method and 2′,3,3′,4,4′,5,5′,6,6′-decachlorobiphenyl was used as internal standard.The GC-MS experimental results show,that the average spiked recoveries ranged from 81% to 110%,that the relative standard deviations(RSD) ranged from 1.54% to 8.65%.The research results also showed that the method presented simplicity-operating,excellent linearity and reproducibility.展开更多
Basic components of Provider Backbone Bridge (PBB) network models were constructed: PBB interior switch, PBB edge switch—with the dynamic filling up of address tables. The modeling of PBB networks was implemented. Th...Basic components of Provider Backbone Bridge (PBB) network models were constructed: PBB interior switch, PBB edge switch—with the dynamic filling up of address tables. The modeling of PBB networks was implemented. The results of simulation reveal definite imperfections of PBB technology caused by the broad-casting and sensitivity to the ageing time of the address tables’ records, which complicates the guaranteeing of a given QoS. The preliminary comparison confirms definite advantages of E6 addressing before PBB.展开更多
文摘Poly brominated biphenyl(PBBs) and poly brominated diphenyl ether(PBDEs) in polymers of electrotechnical products have been extracted with toluene and analyzed by gas chromatography-mass spectrometry (GC-MS).The result has more credibility when the nature of the sample was determined by retention time and the proportion of characteristic ions.PBBs and PBDEs were quantified by internal standard method and 2′,3,3′,4,4′,5,5′,6,6′-decachlorobiphenyl was used as internal standard.The GC-MS experimental results show,that the average spiked recoveries ranged from 81% to 110%,that the relative standard deviations(RSD) ranged from 1.54% to 8.65%.The research results also showed that the method presented simplicity-operating,excellent linearity and reproducibility.
文摘Basic components of Provider Backbone Bridge (PBB) network models were constructed: PBB interior switch, PBB edge switch—with the dynamic filling up of address tables. The modeling of PBB networks was implemented. The results of simulation reveal definite imperfections of PBB technology caused by the broad-casting and sensitivity to the ageing time of the address tables’ records, which complicates the guaranteeing of a given QoS. The preliminary comparison confirms definite advantages of E6 addressing before PBB.