AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC ...AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT展开更多
采用程序升温汽化(programmed temperature vaporization,PTV)大体积进样与气相色谱-质谱选择离子扫描模式(GC/MS-SIM)联用,检测了卷烟主流烟气中苯并[a]芘(benzo[a]pyrene B[a]P),优化了PTV-GC/MS-SIM检测卷烟烟气B[a]P的参数。样品经...采用程序升温汽化(programmed temperature vaporization,PTV)大体积进样与气相色谱-质谱选择离子扫描模式(GC/MS-SIM)联用,检测了卷烟主流烟气中苯并[a]芘(benzo[a]pyrene B[a]P),优化了PTV-GC/MS-SIM检测卷烟烟气B[a]P的参数。样品经反相C18固相萃取柱(solid-phase extraction,SPE)纯化后的洗脱液不再需要浓缩,直接应用PTV技术进样,提高了洗脱液的利用率,缩短了分析时间,提高了GC/MS-SIM检测卷烟烟气B[a]P的灵敏度。展开更多
To measure the surface flow in a physical river model, an improved system of Large-Scale Particle Tracking Velocimetry (LSPTV) was proposed and the elements of the PTV system were described. Usually the tracer parti...To measure the surface flow in a physical river model, an improved system of Large-Scale Particle Tracking Velocimetry (LSPTV) was proposed and the elements of the PTV system were described. Usually the tracer particles of a PTV system seeded on water surface tend to form conglomerates due to surface tension of water. In addition, they can not float on water surface when water flow is shallow. Ellipsoid particles were used to avoid the above problems. Another important issue is particle recognition. In order to eliminate the influence of noise, particles were recognized by the processing of multi-frame images. The kernel of the improved PTV system is the algorithm for particle tracking. A new 3-frame PTV algorithm was developed. The performance of this algorithm was compared with the conventional 4-frame PTV algorithm and 2-frame PTV algorithm by means of computer simulation using synthetically generated images. The results show that the new 3-frame PTV algorithm can recover more velocity vectors and have lower relative error. In addition, in order to attain the whole flow field from individual flow fields, the method of stitching individual flow fields by obvious marks was worked out. Then the improved PTV system was applied to the measurement of surface flow field in Model Yellow River and shows good performance.展开更多
Our previous study showed that the frictional drag decreases with increasing void fraction at Re〉1300, while it increases at Re 〈 1000. Decomposition of the Reynolds shear stress also implied that bubbles induce iso...Our previous study showed that the frictional drag decreases with increasing void fraction at Re〉1300, while it increases at Re 〈 1000. Decomposition of the Reynolds shear stress also implied that bubbles induce isotropy of turbulence. In order to confirm our previous analysis and to further investigate flow fields in the vicinity of bubbles, we analyze velocity fluctuations on the quadrant space in the streamwise and transverse directions (u′-v′ plane). Here, we focus on two specific Reynolds numbers (at Re≈900 and ≈1410, which are close to the laminar-to-turbulent transition regime) and discuss bubble effects on sweep (u′〉 0, v′〈 0 ) and ejection (u′〈 0, v′〉 0) events as a function of the Reynolds number. We also illustrate velocity fluctuations in the vicinity of an individual bubble and a swarm of bubbles on the u′- v′ coordinates. The results show that a bubble swarm suppresses the velocity fluctuations at Re≈1410.展开更多
Background: The treatment of brain metastases with radiotherapy has shifted to the use of Stereotactic Radio-surgery (SRS). The technical issue of expanding the treatment volume around the Gross Tumor Volume (GTV) is ...Background: The treatment of brain metastases with radiotherapy has shifted to the use of Stereotactic Radio-surgery (SRS). The technical issue of expanding the treatment volume around the Gross Tumor Volume (GTV) is a current debate. Radiotherapy centers use variable GTV-PTV margins, ranging from one to 2 mm. Material and Methods: We performed a dosimetric comparison in plans of twenty patients using three margins: PTV zero, PTV1, and PTV2. We also developed imaginary Peel volumes. These volumes are described as follows: Peel1 = PTV1 − GTV, Peel2 = PTV2 − GTV. Results: Our results showed that the mean PTV volume differed significantly across the different margins (p = 0.000). The V12 of the brain significantly varied as a function of PTV margin (p = 0.000). The target coverage and plan quality indices were not significantly different. The Peel volume dosimetric analysis showed that the mean dose was significantly higher in the nearby normal brain tissue: Peel1 (p = 0.022) and Peel 2 (p = 0.013). Conclusion: According to our dosimetric analysis, expanding the GTV into a PTV by 1 mm margin is more convenient than 2 mm.展开更多
Channel flows of Plate Heat Exchangers (PHEs) were assessed by experiments with three different chevron angle arrangements in turbulent regime. Two chevron angles were selected to assess low and high pressure drop cha...Channel flows of Plate Heat Exchangers (PHEs) were assessed by experiments with three different chevron angle arrangements in turbulent regime. Two chevron angles were selected to assess low and high pressure drop channels, besides a third mixed configuration as to achieve in-between results regarding hydraulic performance. Friction factor correlations were provided with the channel Reynolds number ranging from 1175 to 8325. Two-dimensional (2D) mean velocity field was obtained by Particle Tracking Velocimetry (PTV) with Reynolds number equal to 3450. To the best of our knowledge, this is the first experimental study that quantified the complete 2D velocity field of a typical PHE channel. This value allowed comparison with literature results of Plate and Shell Heat Exchanger (PSHE) channels with the same Reynolds number. PSHE mean velocity field is highly heterogeneous as compared to the one obtained for PHE channels. Peak velocity magnitude in the PSHE center is 50% higher than its bulk velocity, whereas this value is only 15% higher in the PHE center. Pressure drop in PHE mixed channels cannot be approximated by averaging chevron angles: furrow flow prevailed in the specified conditions. The axial velocity is asymmetric regarding the vertical plane. Smooth streamlines prevail in the channel inlet. Recirculation zones at the channel exit affect pipe flow in the manifold outlet with swirling flow structures. The necessary length to obtain fully developed pipe flow at the channel outlet was estimated. Significant velocity components occur in the distribution areas and can limit the heat exchanger performance. The results reported herein are essential to understand how the PHE channel geometry affects the velocity field and, therefore, local heat transfer and dissipation processes.展开更多
基金Supported by The National Natural Science Foundation of China, No. 30870738
文摘AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT
文摘采用程序升温汽化(programmed temperature vaporization,PTV)大体积进样与气相色谱-质谱选择离子扫描模式(GC/MS-SIM)联用,检测了卷烟主流烟气中苯并[a]芘(benzo[a]pyrene B[a]P),优化了PTV-GC/MS-SIM检测卷烟烟气B[a]P的参数。样品经反相C18固相萃取柱(solid-phase extraction,SPE)纯化后的洗脱液不再需要浓缩,直接应用PTV技术进样,提高了洗脱液的利用率,缩短了分析时间,提高了GC/MS-SIM检测卷烟烟气B[a]P的灵敏度。
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 50479068, 50779014)the Technological Innovation Project of Graduate students in Jiangsu Province (Grant No.1306014)the Project of "Six Talent Peak" of Jiangsu Province (Grant No. 07-A-006).
文摘To measure the surface flow in a physical river model, an improved system of Large-Scale Particle Tracking Velocimetry (LSPTV) was proposed and the elements of the PTV system were described. Usually the tracer particles of a PTV system seeded on water surface tend to form conglomerates due to surface tension of water. In addition, they can not float on water surface when water flow is shallow. Ellipsoid particles were used to avoid the above problems. Another important issue is particle recognition. In order to eliminate the influence of noise, particles were recognized by the processing of multi-frame images. The kernel of the improved PTV system is the algorithm for particle tracking. A new 3-frame PTV algorithm was developed. The performance of this algorithm was compared with the conventional 4-frame PTV algorithm and 2-frame PTV algorithm by means of computer simulation using synthetically generated images. The results show that the new 3-frame PTV algorithm can recover more velocity vectors and have lower relative error. In addition, in order to attain the whole flow field from individual flow fields, the method of stitching individual flow fields by obvious marks was worked out. Then the improved PTV system was applied to the measurement of surface flow field in Model Yellow River and shows good performance.
文摘Our previous study showed that the frictional drag decreases with increasing void fraction at Re〉1300, while it increases at Re 〈 1000. Decomposition of the Reynolds shear stress also implied that bubbles induce isotropy of turbulence. In order to confirm our previous analysis and to further investigate flow fields in the vicinity of bubbles, we analyze velocity fluctuations on the quadrant space in the streamwise and transverse directions (u′-v′ plane). Here, we focus on two specific Reynolds numbers (at Re≈900 and ≈1410, which are close to the laminar-to-turbulent transition regime) and discuss bubble effects on sweep (u′〉 0, v′〈 0 ) and ejection (u′〈 0, v′〉 0) events as a function of the Reynolds number. We also illustrate velocity fluctuations in the vicinity of an individual bubble and a swarm of bubbles on the u′- v′ coordinates. The results show that a bubble swarm suppresses the velocity fluctuations at Re≈1410.
文摘Background: The treatment of brain metastases with radiotherapy has shifted to the use of Stereotactic Radio-surgery (SRS). The technical issue of expanding the treatment volume around the Gross Tumor Volume (GTV) is a current debate. Radiotherapy centers use variable GTV-PTV margins, ranging from one to 2 mm. Material and Methods: We performed a dosimetric comparison in plans of twenty patients using three margins: PTV zero, PTV1, and PTV2. We also developed imaginary Peel volumes. These volumes are described as follows: Peel1 = PTV1 − GTV, Peel2 = PTV2 − GTV. Results: Our results showed that the mean PTV volume differed significantly across the different margins (p = 0.000). The V12 of the brain significantly varied as a function of PTV margin (p = 0.000). The target coverage and plan quality indices were not significantly different. The Peel volume dosimetric analysis showed that the mean dose was significantly higher in the nearby normal brain tissue: Peel1 (p = 0.022) and Peel 2 (p = 0.013). Conclusion: According to our dosimetric analysis, expanding the GTV into a PTV by 1 mm margin is more convenient than 2 mm.
文摘Channel flows of Plate Heat Exchangers (PHEs) were assessed by experiments with three different chevron angle arrangements in turbulent regime. Two chevron angles were selected to assess low and high pressure drop channels, besides a third mixed configuration as to achieve in-between results regarding hydraulic performance. Friction factor correlations were provided with the channel Reynolds number ranging from 1175 to 8325. Two-dimensional (2D) mean velocity field was obtained by Particle Tracking Velocimetry (PTV) with Reynolds number equal to 3450. To the best of our knowledge, this is the first experimental study that quantified the complete 2D velocity field of a typical PHE channel. This value allowed comparison with literature results of Plate and Shell Heat Exchanger (PSHE) channels with the same Reynolds number. PSHE mean velocity field is highly heterogeneous as compared to the one obtained for PHE channels. Peak velocity magnitude in the PSHE center is 50% higher than its bulk velocity, whereas this value is only 15% higher in the PHE center. Pressure drop in PHE mixed channels cannot be approximated by averaging chevron angles: furrow flow prevailed in the specified conditions. The axial velocity is asymmetric regarding the vertical plane. Smooth streamlines prevail in the channel inlet. Recirculation zones at the channel exit affect pipe flow in the manifold outlet with swirling flow structures. The necessary length to obtain fully developed pipe flow at the channel outlet was estimated. Significant velocity components occur in the distribution areas and can limit the heat exchanger performance. The results reported herein are essential to understand how the PHE channel geometry affects the velocity field and, therefore, local heat transfer and dissipation processes.