In recent years, the effects of reactive oxygen species(ROS) generated in the course of biological metabolism, such as superoxide(O2 ), hydrogen peroxide(H202), hydroxyl radical(HO) and singlet oxygen(102) o...In recent years, the effects of reactive oxygen species(ROS) generated in the course of biological metabolism, such as superoxide(O2 ), hydrogen peroxide(H202), hydroxyl radical(HO) and singlet oxygen(102) on the human health have received more attention due to their vital roles in physiological functions. Normally, antioxidant molecules, superoxide dismutase and catalase in biological organism can scavenge excessive free radicals by a series of chemical reactions to keep the cells in a state of redox homeostasis. Once the homeostasis has been broken,展开更多
Four sensing membranes based on fluorescence quenching were prepared by sol-gel method and CA membrane method, and the Ru(Ⅱ) complexes, Ru( bpy)3 Cl2 and Ru(phen)3 Cl2 , were used as the indicators . The results indi...Four sensing membranes based on fluorescence quenching were prepared by sol-gel method and CA membrane method, and the Ru(Ⅱ) complexes, Ru( bpy)3 Cl2 and Ru(phen)3 Cl2 , were used as the indicators . The results indicate that the volume fraction of oxygen o2 have a linear relationship in large scale with tan0/tanfor all of the sensing membranes. They have super properties such as excellent limit of detection ,fast response time and good reproducibility. The stability of the sensing membranes made by sol-gel method is better than those by CA membranes, but the uniformity of the latter is better than that of the former.展开更多
A fiber optic 2-cholrophenol(2-CP) sensor was developed based on the fluorescence quenching of molecular oxygen on the oxygen-sensitive membrane and O2 consumption during catalytic oxidation reaction of 2-CP. The 2-...A fiber optic 2-cholrophenol(2-CP) sensor was developed based on the fluorescence quenching of molecular oxygen on the oxygen-sensitive membrane and O2 consumption during catalytic oxidation reaction of 2-CP. The 2-CP concentration can be determined by utilizing a lock-in amplifier to measure the change in the fluorescence lifetime of an oxygen-sensitive membrane, in which the tris(2,2′-bipyridyl) ruthenium(II) chloride complexes(Ru(II)(byp)3Cl2) were immobilized in cellulose acetate(CA) via simple hybridized approach. The experimental results show the good linear relationship between the phase delay of sensitive membrane and 2-CP concentration in its detection range of 1×10-7 to 1×10-5 mol/L and 1×10-5 to 1×10-4 mol/L. The detection limit of the sensor is 7×10-8 mol/L(S/N=3) and the response time is 5 min. Our experimental measurements confirmed good response characteristics of the as-prepared fiber optic 2-CP sensor, as well as its capability to detect the 2-CP concentration in practical water samples.展开更多
基金Supported by the Natural Science Foundation of Shandong Province,China(No.Y2006B31)
文摘In recent years, the effects of reactive oxygen species(ROS) generated in the course of biological metabolism, such as superoxide(O2 ), hydrogen peroxide(H202), hydroxyl radical(HO) and singlet oxygen(102) on the human health have received more attention due to their vital roles in physiological functions. Normally, antioxidant molecules, superoxide dismutase and catalase in biological organism can scavenge excessive free radicals by a series of chemical reactions to keep the cells in a state of redox homeostasis. Once the homeostasis has been broken,
基金Funded by The Key Scientific Project Foundation of Hubei Province (No.2001AA101A02) and Natural Science Foundation of Hubei Province (No.2001ABB074)
文摘Four sensing membranes based on fluorescence quenching were prepared by sol-gel method and CA membrane method, and the Ru(Ⅱ) complexes, Ru( bpy)3 Cl2 and Ru(phen)3 Cl2 , were used as the indicators . The results indicate that the volume fraction of oxygen o2 have a linear relationship in large scale with tan0/tanfor all of the sensing membranes. They have super properties such as excellent limit of detection ,fast response time and good reproducibility. The stability of the sensing membranes made by sol-gel method is better than those by CA membranes, but the uniformity of the latter is better than that of the former.
基金Funded by the National Natural Science Foundation of China(No.61377092)
文摘A fiber optic 2-cholrophenol(2-CP) sensor was developed based on the fluorescence quenching of molecular oxygen on the oxygen-sensitive membrane and O2 consumption during catalytic oxidation reaction of 2-CP. The 2-CP concentration can be determined by utilizing a lock-in amplifier to measure the change in the fluorescence lifetime of an oxygen-sensitive membrane, in which the tris(2,2′-bipyridyl) ruthenium(II) chloride complexes(Ru(II)(byp)3Cl2) were immobilized in cellulose acetate(CA) via simple hybridized approach. The experimental results show the good linear relationship between the phase delay of sensitive membrane and 2-CP concentration in its detection range of 1×10-7 to 1×10-5 mol/L and 1×10-5 to 1×10-4 mol/L. The detection limit of the sensor is 7×10-8 mol/L(S/N=3) and the response time is 5 min. Our experimental measurements confirmed good response characteristics of the as-prepared fiber optic 2-CP sensor, as well as its capability to detect the 2-CP concentration in practical water samples.