Considering the issues of energy saving and environment protection,the performance of refrigeration systems requires to be improved.In recent years,nano-fluids have attracted greatly attention from the researchers due...Considering the issues of energy saving and environment protection,the performance of refrigeration systems requires to be improved.In recent years,nano-fluids have attracted greatly attention from the researchers due to their outstanding thermal characteristics.In this work,the published investigations on the preparation and characterization of nano-fluids have been discussed at first.Furthermore,the key thermo-physical properties of nano-fluids,such as thermal conductivity,viscosity,specific heat and density have been summarized.Finally,the performance enhancements in different types of refrigeration systems by using nano-fluids have been reviewed.It is concluded that nano-fluids as refrigerant,lubricant or secondary fluid have wide potential application in refrigeration systems.展开更多
The purpose of the present experimental work is to investigate the performance (1 ton) refrigeration system using nano-refrigerant. Nano-refrigerant is alumina (v-A1203) nanopartcal with size (20-30) nm is dispe...The purpose of the present experimental work is to investigate the performance (1 ton) refrigeration system using nano-refrigerant. Nano-refrigerant is alumina (v-A1203) nanopartcal with size (20-30) nm is dispersed into R-134a with volume fraction 0.01% and 0.02%. The experimental test rig consists of horizontal double tube counter flow heat exchanger fabricated of copper. The nano-refrigerant is evaporated inside the inner tube because of the heat gain from hot water passing in the annulus surrounding the inner tube. The experimental results indicate, when increasing the volume concentration of A1203 refrigerant by 0.01% and 0.02%, the heat transfer coefficient increases by 0.54% to 1.1%. The thermal conductivity increases by 11.5% and 14.2%, respectively, while the coefficient of performance increases by 3.33% to 12%, respectively. The heat transfer rate in the refrigeration side is enhancement about 6.7% to 21.4% compared with conventional refrigerant, and the power consumption by compressor is decreased by nearly 1.6% and 3.3%, respectively.展开更多
基金National Natural Science Foundation of China(No.51906013)The Pyramid Talent Training Project of Beijing University of Civil Engineering and Architecture,China(JDYC20200316)。
文摘Considering the issues of energy saving and environment protection,the performance of refrigeration systems requires to be improved.In recent years,nano-fluids have attracted greatly attention from the researchers due to their outstanding thermal characteristics.In this work,the published investigations on the preparation and characterization of nano-fluids have been discussed at first.Furthermore,the key thermo-physical properties of nano-fluids,such as thermal conductivity,viscosity,specific heat and density have been summarized.Finally,the performance enhancements in different types of refrigeration systems by using nano-fluids have been reviewed.It is concluded that nano-fluids as refrigerant,lubricant or secondary fluid have wide potential application in refrigeration systems.
文摘The purpose of the present experimental work is to investigate the performance (1 ton) refrigeration system using nano-refrigerant. Nano-refrigerant is alumina (v-A1203) nanopartcal with size (20-30) nm is dispersed into R-134a with volume fraction 0.01% and 0.02%. The experimental test rig consists of horizontal double tube counter flow heat exchanger fabricated of copper. The nano-refrigerant is evaporated inside the inner tube because of the heat gain from hot water passing in the annulus surrounding the inner tube. The experimental results indicate, when increasing the volume concentration of A1203 refrigerant by 0.01% and 0.02%, the heat transfer coefficient increases by 0.54% to 1.1%. The thermal conductivity increases by 11.5% and 14.2%, respectively, while the coefficient of performance increases by 3.33% to 12%, respectively. The heat transfer rate in the refrigeration side is enhancement about 6.7% to 21.4% compared with conventional refrigerant, and the power consumption by compressor is decreased by nearly 1.6% and 3.3%, respectively.