An inversion decomposition method for better energy resolution of NaI(Tl)scintillation detectors based on a Gaussian response matrix 被引量:5
1
作者 Jian-Feng He Yao-Zong Yang +3 位作者 Jin-Hui Qu Qi-Fan Wu Hai-Ling Xiao Cong-Cong Yu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期58-67,共10页
NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution ... NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides. 展开更多
关键词 闪烁探测器 能量分辨率 响应矩阵 分解方法 nai 高斯 放射性核素 反演
下载PDF
Comparison of the simulated gamma-ray attenuation coefficients with the real measurements
2
作者 E.E.Ermis E.Pilicer C.Celiktas 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第5期53-57,共5页
The gamma-ray linear and the mass attenuation coefficients of Pb, Al, Cu, and plexiglass materials were calculated from both experimental and theoretical(simulation) methods. For the experimental results, a spectromet... The gamma-ray linear and the mass attenuation coefficients of Pb, Al, Cu, and plexiglass materials were calculated from both experimental and theoretical(simulation) methods. For the experimental results, a spectrometer, which was consisted of a Na I(Tl) inorganic scintillation detector, was used. The theoretical attenuation values were calculated by means of the FLUKA Monte Carlo(MC) and XCOM programs. Obtained attenuation coefficients from the experiment and the theoretical methods were compared with each other and literature values. 展开更多
关键词 质量衰减系数 Γ射线 实际测量 模拟 理论计算方法 闪烁体探测器 蒙特卡罗方法 玻璃材料