期刊文献+
共找到45篇文章
< 1 2 3 >
每页显示 20 50 100
Acrysof ReSTOR多焦点人工晶状体临床应用的初步报告 被引量:22
1
作者 黄蒂 施玉英 《眼科》 CAS 2006年第5期344-347,共4页
目的比较白内障超声乳化联合植入Acrysof ReSTOR(多焦点人工晶状体)及Acrysof Natural(单焦点人工晶状体)术后人工晶状体眼的视功能状态,评价多焦点人工晶状体的临床效果及安全性。设计非随机化临床试验。研究对象53例(61眼)老年性白内... 目的比较白内障超声乳化联合植入Acrysof ReSTOR(多焦点人工晶状体)及Acrysof Natural(单焦点人工晶状体)术后人工晶状体眼的视功能状态,评价多焦点人工晶状体的临床效果及安全性。设计非随机化临床试验。研究对象53例(61眼)老年性白内障患者按自愿选择的原则分为两组,多焦点人工晶状体组28例(31眼),单焦点人工晶状体组(对照组)25例(30眼)。方法全部患者行白内障超声乳化吸除术,按分组植入不同类型的人工晶状体。术后1周、1个月、3个月观察术眼远、近视力及焦点深度范围。主要指标非矫正远、近视力,最佳矫正远、近视力.矫正远视力下近视力,焦点深度范围。结果多焦点人工晶状体组患者术后3个月平均裸眼远视力0.90±0.15,平均裸眼近视力0.70±0.19,矫正远视力下近视力0.73±0.21,焦点深度范围5.5D(+1.5D~-4.0D)。术后1个月时裸眼远、近视力较1周时显著提高(P=0.00l,P=0.000)。单焦点人工晶状体组患者术后3个月平均裸眼远视力0.84±0.14,平均裸眼近视力0.36±0.10,矫正远视力下近视力0.26±0.08,焦点深度范围2.5D(+1.0D~-1.5D)。结论Acrysof ReSTOR可为患者提供良好的远、近视力,降低白内障患者术后对眼镜的依赖。手术效果满意,是一种较为理想的人工晶状体。(眼科,2006,15:344-347) 展开更多
关键词 白内障超声乳化摘除术 人工晶状体 多焦点 单焦点
原文传递
连续视程人工晶状体与双焦点、单焦点人工晶状体植入术后患者视力、视觉质量及满意度对比分析 被引量:5
2
作者 刘敏锐 彭稚喜 +2 位作者 吴峥峥 杨威 万灵 《眼科新进展》 CAS 北大核心 2023年第2期127-130,共4页
目的比较连续视程人工晶状体与双焦点、单焦点人工晶状体植入术后患者视力、视觉质量及满意度的差异。方法选取2020年10月至12月于我院行超声乳化白内障吸除联合人工晶状体植入术的患者61例61眼。依据患者人工晶状体植入情况分为3组,连... 目的比较连续视程人工晶状体与双焦点、单焦点人工晶状体植入术后患者视力、视觉质量及满意度的差异。方法选取2020年10月至12月于我院行超声乳化白内障吸除联合人工晶状体植入术的患者61例61眼。依据患者人工晶状体植入情况分为3组,连续视程组16例16眼植入Tecnis Symfony连续视程人工晶状体;双焦点组20例20眼植入Tecnis ZMB00一片式非球面双焦点人工晶状体;单焦点组25例25眼植入Tecnis ZCB00一片式非球面单焦点人工晶状体。术后1个月检测患者裸眼远、近视力,绘制离焦曲线,运用双通道视觉质量分析系统OQASⅡ检测植入不同人工晶状体后,患者单眼客观视觉质量。分析并获得客观散射指数(OSI)、调制传递函数截止频率(MTF cut off)、斯特列尔比(SR)、三种对比度(100%、20%、9%)下的模拟对比度视力(OV100%、OV20%、OV9%),通过问卷形式对患者进行满意度调查。结果术后1个月,三组患者33 cm和40 cm裸眼近视力差异均有统计学意义(均为P<0.01),单焦点组患者33 cm和40 cm裸眼近视力均差于双焦点组及连续视程组,差异均有统计学意义(均为P<0.05);连续视程组与双焦点组患者33 cm和40 cm裸眼近视力差异均无统计学意义(均为P>0.05)。术后1个月,连续视程组患者在+1.0 D到-3.5 D跨度视力均优于0.3(logMAR),其中+0.5 D到-1.5 D区间视力平稳且优于0.2(logMAR),连续视程人工晶状体植入术后患者全程视力更加平稳。连续视程组与双焦点组患者相关视觉质量各指标(OSI、MTF cut off、SR、OV100%、OV20%)均优于单焦点组,差异均有统计学意义(均为P<0.05)。OV9%三组间差异无统计学意义(P>0.05)。术后1个月,连续视程组脱镜率为100.0%,总体未戴镜时满意度为87.5%;双焦点组脱镜率为100.0%,总体未戴镜时满意度为80.0%;单焦点组脱镜率为60.0%,总体未戴镜时满意度为60.0%。结论连续视程与双焦点人工晶状体较单焦点人工晶状体植 展开更多
关键词 白内障 人工晶状体 视觉质量 离焦曲线 连续视程 双焦点 单焦点
下载PDF
三焦点人工晶状体术后早期临床观察 被引量:8
3
作者 周星延 王静 +3 位作者 赵江月 丁倩 彭程 张劲松 《中华眼视光学与视觉科学杂志》 CAS CSCD 2018年第6期360-364,共5页
目的:比较三焦点人工晶状体(IOL)与单焦点IOL植入术后早期的视力情况、视觉质量及患者满意度。方法:前瞻性临床研究。选取2016年4-7月就诊于中国医科大学附属第四医院眼科确诊为白内障欲行手术治疗的患者44例(50眼),植入三焦点IOL为实验... 目的:比较三焦点人工晶状体(IOL)与单焦点IOL植入术后早期的视力情况、视觉质量及患者满意度。方法:前瞻性临床研究。选取2016年4-7月就诊于中国医科大学附属第四医院眼科确诊为白内障欲行手术治疗的患者44例(50眼),植入三焦点IOL为实验组(22例,25眼),植入单焦点IOL为对照组(22例,25眼)。随访至术后3个月,测试单眼裸眼远中近视力(LogMAR)、离焦曲线、主观散射光、客观散射指数(OSI)、调制传递函数截止频率(MTFcutoff)、斯特列尔比(SR)、像差,并发放调查问卷统计患者满意度、脱镜率以及光晕发生率。采用配对t检验、Wilcoxon符号秩检验及χ2检验进行数据分析。结果:术后3个月,2组间远视力差异无统计学意义,中、近视力方面,实验组(0.12±0.11、0.17±0.11)优于对照组(0.28±0.08、0.47±0.16)(t=-5.912、-8.504,均P<0.001);实验组(2.02±0.93)的OSI高于对照组(1.13±0.31)(t=-3.311,P=0.001);2组间MTFcutoff、SR、主观散射光以及像差的差异均无统计学意义;实验组在满意度和脱镜率方面优于对照组(χ2=4.50,P=0.034;χ2=30.65,P<0.001),光晕发生率在2组间差异无统计学意义。结论:三焦点IOL植入术后,患者拥有良好的远、中、近全程视力及视觉质量。 展开更多
关键词 人工晶状体 三焦点 单焦点 视觉质量
原文传递
多焦点和单焦点人工晶状体植入术治疗白内障的临床疗效比较 被引量:8
4
作者 李振波 《中华实验眼科杂志》 CAS CSCD 北大核心 2013年第10期973-977,共5页
背景 多焦点人工晶状体(IOL)根据衍射-折射的光学原理,可以产生远近两个焦点,全程视力优于单焦点IOL,可以使白内障患者同时获得良好的远、中、近视力. 目的 比较多焦点IOL植入术与单焦点IOL植入术术后白内障患者的临床疗效.方法 采用... 背景 多焦点人工晶状体(IOL)根据衍射-折射的光学原理,可以产生远近两个焦点,全程视力优于单焦点IOL,可以使白内障患者同时获得良好的远、中、近视力. 目的 比较多焦点IOL植入术与单焦点IOL植入术术后白内障患者的临床疗效.方法 采用前瞻性队列研究设计,纳入2010年6月至2012年9月在潍坊高密市人民医院眼科收治的白内障患者100例100眼,将患者分为多焦点IOL组和单焦点IOL组,2个组间患者人口基线特征匹配.多焦点IOL组在超声乳化白内障摘出术后植入Acrysof ReSTOR SA60D3多焦点IOL,单焦点IOL组植入Acrysof SN60AT单焦点IOL.术后3个月对两组患者术眼的裸眼远视力(UCDVA)、最佳矫正远视力(BCDVA)、裸眼近视力(UCNVA)、最佳矫正近视力(BCNVA)、裸眼中近距离视力(UCMVA)和远视力矫正后的近视力(DCNVA)等指标进行观察和比较,对两组患者术后的近立体视锐度以及瞳孔直径分别为3 mm和5 mm时的IOL高阶像差、最适阅读距离和阅读速度等进行比较和分析,通过问卷调查对两组患者对各视觉功能区的满意度进行分析. 结果 术后3个月多焦点IOL组术眼的UCNVA和DCNVA明显优于单焦点IOL组,差异均有统计学意义(t=15.48、22.44,P<0.05);多焦点IOL组术眼在25、30、40、50、60 cm的近距离、中距离处视力均明显优于单焦点IOL组,差异均有统计学意义(t=12.60、16.75、23.18、14.04、7.60,均P<0.05);多焦点IOL组患者的裸眼近立体视锐度为(49.1±l5.2)”,明显小于单焦点IOL组的(85.3±18.6)”,差异有统计学意义(t=10.66,P<0.05);2个组间患者瞳孔直径为3 mm和5 mm时术眼的总高阶像差、球差及彗差的差异均无统计学意义(P>0.05);多焦点IOL组患者的最适阅读距离为(33.5±4.1)cm,较单焦点IOL组的(46.3±5.2)cm明显缩短,差异有统计学意义(t=13.67,P<0.05);多焦点IOL组患者的阅读速度为(172. 展开更多
关键词 人工晶状体 多焦点 单焦点 白内障 视觉质量
下载PDF
同轴微切口超乳联合AcrySof ReSTOR人工晶状体植入治疗年龄相关性白内障 被引量:7
5
作者 冯督 李新 《国际眼科杂志》 CAS 北大核心 2019年第8期1297-1300,共4页
目的:探究同轴微切口白内障超声乳化联合AcrySof ReSTOR人工晶状体植入治疗年龄相关性白内障的疗效。方法:选择2015-04/2017-08我院收治的66例66眼年龄相关性白内障患者纳入研究,所有患者均行同轴微切口白内障超声乳化联合人工晶状体植... 目的:探究同轴微切口白内障超声乳化联合AcrySof ReSTOR人工晶状体植入治疗年龄相关性白内障的疗效。方法:选择2015-04/2017-08我院收治的66例66眼年龄相关性白内障患者纳入研究,所有患者均行同轴微切口白内障超声乳化联合人工晶状体植入治疗,其中32例患者植入AcrySof ReSTOR人工晶状体,纳入观察组,34例植入单焦点人工晶状体,纳入对照组,比较两组患者视力、对比敏感度、立体视锐度、拟调节力及视功能满意度等指标。结果:术后3mo观察组裸眼近、中视力、近立体视锐度、视近拟调节力及视远拟调节力显著优于对照组(P<0.05);在空间频率为3、6、12、18c/d时,观察组在有眩光及无眩光条件下对比敏感度均显著低于对照组(P<0.05);观察组视功能相关生活质量量表、视近时满意度及戴镜评分均显著优于对照组(P<0.05)。结论:同轴微切口超声乳化联合AcrySof ReSTOR人工晶状体植入治疗年龄相关性白内障疗效显著,与单焦点晶状体相比可提高视近视力,提高拟调节力及视觉相关生活质量,但对比敏感度有所降低。 展开更多
关键词 白内障超声乳化 单焦点 多焦点 白内障 人工晶状体 对比敏感度
下载PDF
老年性白内障多焦点IOL同轴微切口植入的视觉质量观察 被引量:7
6
作者 杨卫华 《国际眼科杂志》 CAS 2016年第4期748-751,共4页
目的:探讨老年性白内障多焦点人工晶状体(multiple focal intraocular lens,MIOL)同轴微切口植入的视觉效果。方法:回顾性非随机病例对照研究。选择2013-02/2014-08在湖州师范学院附属第一医院植入AcrySof ReSTOR人工晶状体的老年性白... 目的:探讨老年性白内障多焦点人工晶状体(multiple focal intraocular lens,MIOL)同轴微切口植入的视觉效果。方法:回顾性非随机病例对照研究。选择2013-02/2014-08在湖州师范学院附属第一医院植入AcrySof ReSTOR人工晶状体的老年性白内障患者48例60眼为观察组,进行同轴微切口白内障超声乳化联合AcrySof ReSTOR人工晶状体植入。选择同期一般资料匹配的同轴微切口单焦点人工晶状体植入患者36例50眼为对照组。观察并比较两组患者术后裸眼远视力、裸眼近视力、日常用眼满意度。结果:两组患者人工晶状体均成功植入。观察组术后3mo裸眼远视力为0.75±0.25,裸眼近视力为0.70±0.18,日常用眼满意度为96%。对照组术后3mo裸眼远视力为0.79±0.36,裸眼近视力为0.31±0.11,日常用眼满意度为75%。两组患者术后3mo裸眼远视力比较,无统计学差异(P>0.05),术后3mo裸眼近视力、日常用眼满意度比较,有统计学差异(P<0.05)。结论:多焦点人工晶状体术后3mo裸眼近视力、日常用眼满意度优于单焦点人工晶状体。两组患者术后3mo裸眼远视力结果无差异。 展开更多
关键词 白内障 ACRYSOF RESTOR 人工晶状体 多焦点 单焦点 微切口
下载PDF
双眼不同人工晶状体混搭植入矫正老视的临床效果评价 被引量:1
7
作者 郝文娜 马先祯 刘冬梅 《眼科新进展》 CAS 北大核心 2024年第7期578-582,共5页
近年来,功能性人工晶状体(IOL)的应用为白内障患者视觉质量的改善提供了有效选择,术后满意度及脱镜率高,但也存在眩光、立体视损害等不良现象。匹配应用两种不同的IOL进行植入,发挥IOL各自的优点以提供更卓越的术后效果已被越来越多的... 近年来,功能性人工晶状体(IOL)的应用为白内障患者视觉质量的改善提供了有效选择,术后满意度及脱镜率高,但也存在眩光、立体视损害等不良现象。匹配应用两种不同的IOL进行植入,发挥IOL各自的优点以提供更卓越的术后效果已被越来越多的眼科医师重视,探索更优化的IOL植入方案是治疗白内障同时矫治老视的重要课题。本文就IOL混搭植入在治疗白内障同时矫正老视的研究进展进行综述。 展开更多
关键词 混搭植入人工晶状体 单焦点 多焦点 折射 衍射 白内障 老视
下载PDF
Comparison of dynamic defocus curve Checkfor updates on cataract patients implanting extended depth of focus and monofocal intraocular
8
作者 Tingyi Wu Yuexin Wang +4 位作者 jiazhi Yu Xiaotong Ren Yuanting Li Weigiang Qiu Xuemin Li 《Eye and Vision》 SCIE CSCD 2024年第4期32-40,共9页
Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract... Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony(ZXRoO)or monofocal IOLs were enrolled.The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively.Results:The ZXR00 group achieved signifcantly better intermediate(P=0.044)and near(P=0.017)visual acuity(VA)than the monofocal group.Two groups had similar uncorrected and corrected distance VA(P>0.05,respectively).The dynamic defocus curve revealed a smoother decline from 0.0 D to-2.0 D in the ZXRo0 group.Defocused dynamic VA in the ZXR00 group was significantly better(P<0.05)except at 0.0 D(P=0.724)and-0.5 D(P=0.176).The area under the curve(P=0.002)and corrected dynamic vision accommodation(P=0.001)derived from the dynamic defocus curves were better in the ZxRoo group.A positive correlation was observed between defocused dynamic and static VA in both groups(P<0.001).Multiple linear regression analysis indicated that defocused static VA and cor-rected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from-1.0 D to-3.0 D(P<0.05).Conclusions:The EDOF IOL provided similar distant vision,better intermediate and near vision,and a better overall dynamic defocus curve than the monofocal IOL.The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery. 展开更多
关键词 Dynamic defocus curve Age-related cataract Extended depth-of-focus intraocular lens monofocal intraocularlens
原文传递
三焦点与单焦点人工晶状体植入术后1年视觉质量比较 被引量:5
9
作者 秦勤 刘军 +4 位作者 陈晖 李一壮 鲍连云 何自芳 解正高 《中华实验眼科杂志》 CAS CSCD 北大核心 2022年第5期454-460,共7页
目的比较三焦点与单焦点人工晶状体(IOL)植入术后1年视觉质量。方法采用队列研究设计,纳入2017年5月至2018年6月在南京大学医学院附属鼓楼医院行超声乳化白内障摘出联合IOL植入术的年龄相关性白内障患者41例41眼,根据患者意愿将其分为... 目的比较三焦点与单焦点人工晶状体(IOL)植入术后1年视觉质量。方法采用队列研究设计,纳入2017年5月至2018年6月在南京大学医学院附属鼓楼医院行超声乳化白内障摘出联合IOL植入术的年龄相关性白内障患者41例41眼,根据患者意愿将其分为三焦点IOL组20例20眼和单焦点IOL组21例21眼,分别植入AT LISA tri 839MP三焦点IOL和603P单焦点IOL。术后随访1年,检测2个组患者术后1年裸眼远距离视力(UCDVA)、裸眼中距离视力(UCIVA)、裸眼近距离视力(UCNVA)、最佳矫正远视力(BCDVA)、远视力矫正下的中距离视力(DCIVA)和远视力矫正下的近距离视力(DCNVA);采用OQASⅡ检测患者点扩散函数(PSF)、调制传递函数(MTF)截止频率、斯特尔比率(SR),以及对比度分别为100%、20%、9%时的OQASⅡ值(OV 100%、OV 20%、OV 9%)及客观散射指数(OSI);采用iTrace视功能分析仪评估患者的波前像差,包括全眼总像差(TA)、总高阶像差(tHOAs)、球差、彗差、三叶草像差、总低阶像差(tLOAs)、离焦、散光,所有像差值用均方根表示;采用综合验光仪检测2个组患者术眼不同调节范围内的视力,并以高于0.5 LogMAR视力绘制离焦曲线图;采用裂隙灯显微镜观察并以Sellman法量化分析2个组患者IOL区域内后囊膜混浊(PCO)发生程度;采用视功能指数量表(VF-14)对视功能进行评分。结果术后1年,三焦点IOL组患者UCIVA、UCNVA、DCIVA和DCNVA明显优于单焦点IOL组,差异均有统计学意义(均P<0.001)。OQASⅡ视觉质量指标显示,三焦点IOL组患者MTF截止频率、SR、OV 100%及OSI值明显高于单焦点IOL组,差异均有统计学意义(均P<0.001)。2个组患者各波前像差比较,差异均无统计学意义(均P>0.05)。离焦曲线显示,单焦点IOL组组患者在-1.0、-1.5、-2.0、-2.5、-3.0、-3.5 D时(即相当于1 m、66 cm、50 cm、40 cm、33 cm、29 cm)的LogMAR视力明显高于三焦点IOL组,差异均有统计学意义(均P<0.05)。三焦点IOL组 展开更多
关键词 白内障 手术 人工晶状体 三焦点 人工晶状体 单焦点 视觉质量
下载PDF
A systematic review of pseudophakic monovision for presbyopia correction 被引量:3
10
作者 Georgios Labiris Aspa Toli +2 位作者 Aslin Perente Panagiota Ntonti Vassilios P.Kozobolis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期992-1000,共9页
A systematic review of the recent literature regarding pseudophakic monovision as a reliable methods for presbyopia correction was performed based on the PubMed, MEDLINE, Nature and the American Academy of Ophthalmolo... A systematic review of the recent literature regarding pseudophakic monovision as a reliable methods for presbyopia correction was performed based on the PubMed, MEDLINE, Nature and the American Academy of Ophthalmology databases in July 2015 and data from 18 descriptive and 12 comparative studies were included in this narrative review. Pseudophakic monosvision seems to be an effective method for presbyopia with high rates of spectacles independence and minimal dysphotopsia side- effects, that should be considered by the modern cataract surgeons. 展开更多
关键词 pseudophakic monovision presbyopia correc-tion cataract extraction mini-monovision monofocal intraoc-ular lens lens implantation
下载PDF
两种不同类型人工晶状体植入术后调节力的比较 被引量:5
11
作者 胡晓丹 江晓丹 +3 位作者 吕会斌 杨嘉瑞 李罗佳 李学民 《中国实用眼科杂志》 2016年第10期1067-1071,共5页
【摘要】目的对比分析植入可调节人工晶状体和单焦点人工晶状体术后患者的调节力,寻找解决白内障患者术后调节力不足的方法。方法临床病例对照研究。对2014年1至9月在北京大学第三医院眼科接受白内障超声乳化联合人工晶状体植入术患者5... 【摘要】目的对比分析植入可调节人工晶状体和单焦点人工晶状体术后患者的调节力,寻找解决白内障患者术后调节力不足的方法。方法临床病例对照研究。对2014年1至9月在北京大学第三医院眼科接受白内障超声乳化联合人工晶状体植入术患者51例(69只眼)。根据植入人工晶状体类型分为2组。可调节人工晶状体组(Tetraflex KH-3500)(A组,20例30只眼)和单焦点人工晶状体组(Tecnis ZCB00)(B组,31例39只眼)。术后3个月进行随访,对术眼进行裸眼远视力、最佳矫正远视力、裸眼近视力、最佳矫正近视力及调节力检查。结果两组患者术后均可以获得好的裸眼远视力、最佳矫正远视力以及较好的最佳矫正近视力,差异比较均无统计学意义(P〉0.05)。而A组的裸眼近视力明显优于B组(P〈0.01)。A组患者术后的平均调节力为2.85(2.70~3.26)D,B组患者则为0.95(0.63—1.35)D,两者间差异有统计学意义(Z=-7.105,P〈0.01)。结论相比于单焦点人工晶状体,可调节人工晶状体植入后能使患者获得更加优越的裸眼近视力,显著改善白内障手术患者的调节力。 展开更多
关键词 人工晶状体 可调节 单焦点 调节力
原文传递
Encouraging Visual Outcome of a New Accommodative Intraocular Lens: A Retrospective Long-Term Study with a Mean Follow-Up of 5.3 Years
12
作者 Jacob Ritter Justus Petrick +2 位作者 Anna-Lena Kloberdanz Charlotte Rammler Violeta Doci 《Open Journal of Ophthalmology》 2022年第4期416-429,共14页
Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients we... Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation. 展开更多
关键词 Accommodative Intraocular Lens Cataract Surgery monofocal Intraocular Lens Visual Acuity
下载PDF
超声乳化联合TECNIS散光矫正型人工晶状体植入治疗白内障的临床效果 被引量:3
13
作者 张秀杰 《中国实用医刊》 2022年第2期62-66,共5页
目的:探讨超声乳化联合TECNIS散光矫正型(Toric)人工晶状体(IOL)植入术治疗白内障的效果。方法:抽取2020年1月至2021年6月周口市眼科医院收治的90例(98眼)角膜散光≥0.75 D的白内障患者,随机分为甲组(45例51眼)、乙组(45例47眼),两组均... 目的:探讨超声乳化联合TECNIS散光矫正型(Toric)人工晶状体(IOL)植入术治疗白内障的效果。方法:抽取2020年1月至2021年6月周口市眼科医院收治的90例(98眼)角膜散光≥0.75 D的白内障患者,随机分为甲组(45例51眼)、乙组(45例47眼),两组均行超声乳化联合IOL植入术,甲、乙组分别植入TECNIS非球面多焦点Toric IOL ZMA000、TECNIS非球面单焦点IOL,比较两组术前、术后1周、术后3个月裸眼远视力(UDVA)、裸眼近视力(UNVA)、最佳矫正近视力(BCNVA)、最佳矫正远视力(BCDVA)、残余散光度,术后3个月不同空间频率对比敏感度(CS)及视觉质量指标客观散射指数(OSI)、斯特利尔比值(SR)、调制传递函数(MTF)截止空间频率的变化,统计术后3个月脱镜率及视觉干扰情况。结果:甲组术后1周、3个月UNVA、BCNVA优于乙组( P<0.05);甲组术后1周、术后3个月残余散光度低于乙组( P<0.05);甲组18 c/d空间频率下CS高于乙组( P<0.05);甲组术后3个月OSI、SR、MTF截止空间频率均高于乙组( P<0.05);甲组术后3个月脱镜率高于乙组( P<0.05),两组视觉干扰分级比较, P>0.05。 结论:超声乳化联合TECNIS非球面多焦点Toric IOL ZMA000植入可促进白内障患者远近视力改善,优化全程视力,减少残余散光,且术后早期视觉质量高,CS好,脱镜率高。 展开更多
关键词 白内障 人工晶状体 非球面 多焦点 单焦点
原文传递
衍射型多焦点人工晶状体眼拟调节力的初步报告 被引量:3
14
作者 孙康 张婉琪 +4 位作者 陆强 谢军谊 吕红玲 陈瑞 凌萍 《眼视光学杂志》 2007年第4期245-248,共4页
目的评价白内障超声乳化摘除联合衍射型多焦点人工晶状体植入术后患者的视力及拟调节力。方法将40例(46眼)年龄相关性白内障患者随机分为2组,每组各20例(23眼),分别行白内障超声乳化摘除并植入ReSTORSA60D3衍射型多焦点人工晶状体(多... 目的评价白内障超声乳化摘除联合衍射型多焦点人工晶状体植入术后患者的视力及拟调节力。方法将40例(46眼)年龄相关性白内障患者随机分为2组,每组各20例(23眼),分别行白内障超声乳化摘除并植入ReSTORSA60D3衍射型多焦点人工晶状体(多焦组)和Natural SN60AT单焦点人工晶状体(单焦组),观察术后裸眼远、近视力,最佳矫正远、近视力,最佳视远矫正时近视力以及视近拟调节力。结果两组患者术后裸眼远视力,最佳矫正远视力和最佳矫正近视力差异均无显著性(P>0.05);术后第3个月裸眼远视力≥0.5者多焦组和单焦组均达95.65%。多焦组术后裸眼近视力和最佳视远矫正时近视力明显优于单焦组(P<0.05);术后第3个月裸眼近视力≥0.5者,多焦组为69.57%,单焦组为4.35%;而最佳视远矫正时近视力≥0.5,多焦组为69.57%,单焦组为13.04%。术后第3个月视近拟调节力多焦组为(-3.54±1.05)D,单焦组为(-1.65±0.68)D,差异有显著性(P<0.05)。结论ReSTOR衍射型多焦点人工晶状体能提供良好的远、近视力,拟调节幅度较单焦点人工晶状体大,能有效地提高白内障患者术后的视觉质量。 展开更多
关键词 白内障 超声乳化 多焦点 单焦点 人工晶体
下载PDF
Astigmatic correction with implantation of a light adjustable vs monofocal lens: a single site analysis of a randomized controlled trial 被引量:1
15
作者 Majid Moshirfar William D.Wagner +6 位作者 Steven H.Linn David F.Skanchy Tanner W.Brown Aaron T.Gomez Jackson L.Goldberg Yasmyne C.Ronquillo Phillip C.Hoopes Jr. 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第7期1101-1107,共7页
AIM: To evaluate the light adjustable lens(LAL) vs a standard monofocal lens in achieving target astigmatic refraction and improving postoperative uncorrected distance visual acuity(UDVA). METHODS: This randomized con... AIM: To evaluate the light adjustable lens(LAL) vs a standard monofocal lens in achieving target astigmatic refraction and improving postoperative uncorrected distance visual acuity(UDVA). METHODS: This randomized controlled clinical trial included 40 patients with pre-existing astigmatism and visually significant cataract. Twenty-eight patients received the LAL and 12 control patients received a monofocal intraocular lens(IOL) after cataract extraction at a single institution. The patients with the LAL underwent adjustment by ultraviolet(UV) light postoperatively plus subsequent lock-in procedures and all patients returned to clinic for follow up of study parameters at 6, 9, and 12 mo. Manifest refraction, distance visual acuity, and adverse events were recorded at each visit.RESULTS: The mean cylinder before adjustment in eyes with the LAL was-0.89±0.58 D(-2.00 to 0.00 D) and-0.34±0.34 D(-1.25 to 0.00 D) after lock-in(P=1.68 x10-8). The mean cylinder in patients with the monofocal lens was-1.00±0.32 D(-1.50 to-0.50 D) at 17-21 d postoperatively, which was statistically different from the LAL cylinder postlock-in(P=1.43 x10-6). UDVA in the LAL group was 20/20 or better in 79% of patients post lock-in with good stability over 12 mo compared with 33% of the control patients with UDVA of 20/20 or better. CONCLUSION: These results demonstrate that the LAL is more effective in achieving target refractions and improving postoperative UDVA in patients with pre-existing corneal astigmatism than a standard monofocal lens. 展开更多
关键词 LIGHT ADJUSTABLE LENS monofocal LENS ASTIGMATISM CATARACT
下载PDF
The effects of premium intraocular lenses on presbyopia treatments 被引量:2
16
作者 Yanan Zhu Yueyang Zhong Yanyan Fu 《Advances in Ophthalmology Practice and Research》 2022年第1期18-27,共10页
Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common m... Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common methods of presbyopia correction.During the twentieth century,IOLs have underwent significant innovation and advancements to meet the patients'high demands for functional vision at all distances.Main Text:To meet the increasing needs for excellent near and intermediate vision for daily activities,some premium IOLs with more than one focus have been developed,for example,the refractive MfIOLs,diffractive MfIOLs,extended depth of field(EDOF)IOLs,and accommodating IOLs(AIOLs)were introduced to meet this need.In addition,the add-on MfIOLs have been explored as promising supplementary IOLs for pseudophakic presbyopia.When selecting the MfIOLs,the IOLs'features,patients’characteristics,preoperative eye conditions,and treatment expectations should be considered.Conclusions:In this review,we focus on the multifocal IOLs(MfIOLs)commonly used for presbyopia correction and systematically summarized their optical designs and clinical outcomes.More evidence-based studies are required to provide guidelines for MfIOL selection,provide maximum visual benefits,and develop personalized visual solutions in the future. 展开更多
关键词 PRESBYOPIA Intraocular lens monofocal intraocular lens Multifocal intraocular lens Extended depth of field intraocular lens Accommodating intraocular lens Clinical outcomes
原文传递
A comparison of visual outcomes in three different types of monofocal intraocular lenses
17
作者 Vijay Shetty Suhas S Haldipurkar +3 位作者 Rujuta Gore Rita Dhamankar Anirban Paik Maninder Singh Setia 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第6期1173-1178,共6页
AIMTo compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens).METHODSThe present stud... AIMTo compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens).METHODSThe present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (&#x000b1;3) post-surgery.RESULTSAbout 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good &#x0201c;both near and distance vision&#x0201d; were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both &#x0201c;distance and near vision&#x0201d; compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56).CONCLUSIONMatrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery. 展开更多
关键词 visual acuity monofocal lenses cataract surgery
下载PDF
衍射折射型多焦点人工晶状体远期视觉质量观察 被引量:2
18
作者 戴馨 吕春英 +3 位作者 刘景 李慧 张晗 李镜海 《国际眼科杂志》 CAS 2011年第6期989-991,共3页
目的:测定衍射折射型多焦点人工晶状体眼术后远期的视觉质量。方法:采取随机对照临床试验研究方法,将67例白内障患者分两组,其中30例33眼植入多焦点人工晶状体,37例37眼植入单焦点人工晶状体。术后3mo和1a进行裸眼远视力、中间视力、近... 目的:测定衍射折射型多焦点人工晶状体眼术后远期的视觉质量。方法:采取随机对照临床试验研究方法,将67例白内障患者分两组,其中30例33眼植入多焦点人工晶状体,37例37眼植入单焦点人工晶状体。术后3mo和1a进行裸眼远视力、中间视力、近视力、矫正远、中、近视力和对比敏感度检查。视功能和生存质量调查问卷评价患者主观的视觉功能。结果:(1)术后多焦点组裸眼近视力优于单焦点组(P<0·05),中间距离视力亦优于单焦点组(P<0.05),两组裸眼和矫正远视力、近视力及最佳矫正远视力下近视力差异无显著性。术后1a和3mo相比,差异无显著性意义。(2)术后两组对比敏感度均低于正常范围,空间分布差异无统计学意义。(3)两组术后多焦点组脱镜率达83%,而单焦点组脱镜率为32%,两组比较差异有显著性(P<0·05)。多焦点组4例有眩光。多焦点组患者对全程视力的满意度高于单焦组患者。结论:多焦点人工晶状体能提供良好的全程视力,但近视力更好,视觉症状轻,脱镜率更高,有效地提高白内障患者术后的视觉质量。 展开更多
关键词 白内障 人工晶状体 多焦点 单焦点
下载PDF
三类多焦点人工晶状体及其临床应用 被引量:2
19
作者 汤坚岑 蔡季平 张忆 《国际眼科杂志》 CAS 2012年第6期1085-1087,共3页
随着人们对白内障术后视觉质量要求的提高,多焦点人工晶状体的应用已成为近年来的研究热点。目前多焦点人工晶状体主要分为折射型、衍射型和折射衍射混合型3类。本文拟就此三类多焦点人工晶状体的设计原理及其临床应用现状等作一综述。
关键词 白内障摘除术 人工晶状体 单焦点 多焦点
下载PDF
单焦点、多焦点与可调节人工晶状体植入术后患者的拟调节力观察 被引量:1
20
作者 张良 赵江月 +1 位作者 冯莉 张劲松 《中华眼视光学与视觉科学杂志》 CAS 2013年第1期21-25,共5页
目的研究超声乳化白内障摘除植入不同人工晶状体(IOL)术后患者的拟调节力。方法前瞻性队列研究。行白内障超声乳化吸除联合IOL植入术且随访资料完整的患者73例(82眼),依据植入10L的不同分为3组:单焦点IOL组28例(32眼),多焦点IO... 目的研究超声乳化白内障摘除植入不同人工晶状体(IOL)术后患者的拟调节力。方法前瞻性队列研究。行白内障超声乳化吸除联合IOL植入术且随访资料完整的患者73例(82眼),依据植入10L的不同分为3组:单焦点IOL组28例(32眼),多焦点IOL组24例(27眼),可调节IOL组21例(23眼)。术后3d、1周、1个月、3个月分别测量3组患者的裸眼远、中、近视力,最佳矫正远、近视力.及拟调节力。数据采用单因素方差分析。结果3组的最佳矫正远、近视力及裸眼远视力差异无统计学意义,而裸眼中视力可调节IOL优于单焦点与多焦点IOL(F=4.50,P〈0.05),裸眼近视力多焦点、可调节IOL好于单焦点IOL(F=26.06,P〈0.05)。多焦IOL可以提供(2.67±0.49)D的主观拟调节力,(0.93±0.42)0的客观拟调节力;可调节IOL可以提供(3.00±0.78)D主观拟调节力,(0.91±0.58)D客观拟调节力;优于单焦点10L的(1.78±0.26)D的主观拟调节力(F=18.51,P〈0.05),和(0.37±0.22)D的客观拟调节力(F=7.39,P〈0.05)。结论多焦点IOL与可调节性IOL均可提供较好的全程视力及拟调节力。 展开更多
关键词 白内障 人工晶状体 单焦 多焦 可调节 调节
原文传递
上一页 1 2 3 下一页 到第
使用帮助 返回顶部