Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri...Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.展开更多
Understanding the factors that contribute to population stability in long-distance migrant birds is increasingly important, particularly given global climate change, sea level rise, and loss or disturbance at essentia...Understanding the factors that contribute to population stability in long-distance migrant birds is increasingly important, particularly given global climate change, sea level rise, and loss or disturbance at essential habitats. While the populations of most shorebirds are declining worldwide, those that migrate through Delaware Bay, New Jersey and Delaware, are declining at the most rapid rate despite conservation efforts. In this paper, we 1) provide background information on population declines of red knots (Calidris canutus rufa) using Delaware Bay, threats to their foraging, and efforts to reduce threats, 2) summarize briefly our studies of the effects of human activities on knots and other shorebirds, 3) present data on management efforts to protect knots and other shorebirds from the activities of people, and 4) discuss the efficacy of such efforts (usually referred to as “decreasing the effect of human disturbances”). The Shorebird Project on Delaware Bay is over 25 years old and provides long-term data to help assess the status of shorebird numbers, particularly for red knot, as well as the density of horseshoe crabs (Limulus polyphemus) and their eggs. Red knots have continued to decline even more precipitously in the last few years, presenting cause for concern. Protective efforts have been successful in reducing human disruption on the N.J. Delaware Bay beaches, but the lack of uniformity in implementation across the New Jersey side, and across the whole Bay have hampered further improvements. Implementation of signs, fencing, and stewards on some beaches significantly enhanced the use of these beaches by red knots, determined by examining the use of beaches pre- and post-implementation. Implementation of fencing and stewards had the greatest effect. From 1986 to 2018, there was a significant shift in the percent of Delaware Bay red knots using the NJ side, where protection efforts had been implemented on many of the beaches. Merely restricting access (without fencing or other efforts) did not res展开更多
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bra...Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines.展开更多
Objective Solar ultraviolet (UV) radiation is an important environmental factor that affects human health. The understanding of diurnal variations of UV radiation at anatomical sites may be helpful in developing way...Objective Solar ultraviolet (UV) radiation is an important environmental factor that affects human health. The understanding of diurnal variations of UV radiation at anatomical sites may be helpful in developing ways to protect humans from the harmful effects of UV radiation. Methods In order to characterize the diurnal variations, the UV exposure values were measured at 30 min intervals by using Solar-UV Sensors and a rotating manikin in Shenyang city of China (41°51'N, 123°27%). Measurement data for four representative days (in each of the four seasons respectively) were analyzed. Results The diurnal variations in solar UV radiation at the shoulder, the forehead and the chest were similar to those associated with a horizontal control measurement. However, the diurnal variations at the eye and the cheek exhibited bimodal distributions with two peaks in spring, summer and autumn, and a unimodal distribution in winter. The UV exposure peaks at the eye and the cheek were measured at solar elevation angles (SEA) of about 30° and 40°, respectively. Conclusion The protection of some anatomical sites such as the eye from high UV exposure should not be focused solely on the periods before and after noon, especially in the places and seasons with high SEA.展开更多
Treatment of type 1 diabetes mellitus has always posed a challenge to balance hyperglycemia control with hypoglycemia episodes. The quest for newer therapies is continuing and this review attempts to outline the recen...Treatment of type 1 diabetes mellitus has always posed a challenge to balance hyperglycemia control with hypoglycemia episodes. The quest for newer therapies is continuing and this review attempts to outline the recent developments. The insulin molecule itself has got moulded into different analogues by minor changes in its structure to ensure well controlled delivery, stable half-lives and lesser side effects. Insulin delivery systems have also consistently undergone advances from subcutaneous injections to continuous infusion to trials of inhalational delivery. Continuous glucose monitoring systems are also becoming more accurate and user friendly. Smartphones have also made their entry into therapy of diabetes by integrating blood glucose levels and food intake with calculated adequate insulin required. Artificial pancreas has enabled to a certain extent to close the loop between blood glucose level and insulin delivery with devices armed with meal and exercise announcements, dual hormone delivery and pramlintide infusion. Islet, pancreas-kidney and stem cells transplants are also being attempted though complete success is still a far way off. Incorporating insulin gene and secretary apparatus is another ambitious leap to achieve insulin independence though the search for the ideal vector and target cell is still continuing. Finally to stand up to the statement, prevention is better than cure, immunological methods are being investigated to be used as vaccine to prevent the onset of diabetes mellitus.展开更多
AIM:To determine whether bispectral index (BIS) monitoring is useful for propofol administration for deep sedation during endoscopic retrograde cholangiopancreatography (ERCP). METHODS:Fifty-nine consecutive patients ...AIM:To determine whether bispectral index (BIS) monitoring is useful for propofol administration for deep sedation during endoscopic retrograde cholangiopancreatography (ERCP). METHODS:Fifty-nine consecutive patients with a variety of reasons for ERCP who underwent the procedure at least twice between 1 July 2010 and 30 November 2010. This was a randomized cross-over study, in which each patient underwent ERCP twice, once with BIS monitoring and once with control monitoring. Whether BIS monitoring was done during the first or second ERCP procedure was random. Patients were intermittently administered a mixed regimen including midazolam, pethidine, and propofol by trained nurses. The nurse used a routine practice to monitor sedation using the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scale or the BIS monitoring. The total amount of midazolam and propofol used and serious side effects were compared between the BIS and control groups. RESULTS:The mean total propofol dose administered was 53.1 ± 32.2 mg in the BIS group and 54.9 ± 30.8 mg in the control group (P = 0.673). The individual propofol dose received per minute during the ERCP procedure was 2.90 ± 1.83 mg/min in the BIS group and 3.44 ± 2.04 mg in the control group (P = 0.103). The median value of the MOAA/S score during the maintenance phase of sedation was comparable for the two groups. The mean BIS values throughout the procedure (from insertion to removal of the endoscope) were 76.5 ± 8.7 for all 59 patients in using the BIS monitor. No significant differences in the frequency of < 80% oxygen saturation, hypotension (< 80 mmHg), or bradycardia (< 50 beats/min) were observed between the two study groups. Four cases of poor cooperation occurred, in which the procedure should be stopped to add the propofol dose. After adding the propofol, the procedure could be conducted successfully (one case in the BIS group, three cases in the control group). The endoscopist rated patient sedation as excellent for all patients in both groups. All展开更多
Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in c...Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations.In this paper,to check the offset from the mechanical to electrical center in low temperature(77 K),Fourier's law and finite element method are used to simulate cryo-deformation.Laser tracker and micro-alignment telescope are employed in combined BPM calibration,installation and monitoring.The calibration error is<0.02 mm,and the installation and monitoring precision are 0.06 mm and 0.01 mm,respectively.The monitored cryo-deformation agrees well with the simulation results.These indicate that the combined alignment can improve performance of the BPM system.All these guaranteed the success of running the 9.55 MeV@2.14 mA cw protons.展开更多
文摘Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.
文摘Understanding the factors that contribute to population stability in long-distance migrant birds is increasingly important, particularly given global climate change, sea level rise, and loss or disturbance at essential habitats. While the populations of most shorebirds are declining worldwide, those that migrate through Delaware Bay, New Jersey and Delaware, are declining at the most rapid rate despite conservation efforts. In this paper, we 1) provide background information on population declines of red knots (Calidris canutus rufa) using Delaware Bay, threats to their foraging, and efforts to reduce threats, 2) summarize briefly our studies of the effects of human activities on knots and other shorebirds, 3) present data on management efforts to protect knots and other shorebirds from the activities of people, and 4) discuss the efficacy of such efforts (usually referred to as “decreasing the effect of human disturbances”). The Shorebird Project on Delaware Bay is over 25 years old and provides long-term data to help assess the status of shorebird numbers, particularly for red knot, as well as the density of horseshoe crabs (Limulus polyphemus) and their eggs. Red knots have continued to decline even more precipitously in the last few years, presenting cause for concern. Protective efforts have been successful in reducing human disruption on the N.J. Delaware Bay beaches, but the lack of uniformity in implementation across the New Jersey side, and across the whole Bay have hampered further improvements. Implementation of signs, fencing, and stewards on some beaches significantly enhanced the use of these beaches by red knots, determined by examining the use of beaches pre- and post-implementation. Implementation of fencing and stewards had the greatest effect. From 1986 to 2018, there was a significant shift in the percent of Delaware Bay red knots using the NJ side, where protection efforts had been implemented on many of the beaches. Merely restricting access (without fencing or other efforts) did not res
基金supported by National High-tech Research and Development Program of China (863 Program) (2013AA030701)Science and Technology Project of the State Grid Xinjiang Electric Power Corporation (5230DK15009L)
文摘Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines.
基金supported by the National Natural Science Foundation of China(NSFC30700652,NSFC 30800895)which for the Doctoral Program of Higher Education of China(20070159022)the Liaoning Provincial Science and Technology Development Fund (20062087).
文摘Objective Solar ultraviolet (UV) radiation is an important environmental factor that affects human health. The understanding of diurnal variations of UV radiation at anatomical sites may be helpful in developing ways to protect humans from the harmful effects of UV radiation. Methods In order to characterize the diurnal variations, the UV exposure values were measured at 30 min intervals by using Solar-UV Sensors and a rotating manikin in Shenyang city of China (41°51'N, 123°27%). Measurement data for four representative days (in each of the four seasons respectively) were analyzed. Results The diurnal variations in solar UV radiation at the shoulder, the forehead and the chest were similar to those associated with a horizontal control measurement. However, the diurnal variations at the eye and the cheek exhibited bimodal distributions with two peaks in spring, summer and autumn, and a unimodal distribution in winter. The UV exposure peaks at the eye and the cheek were measured at solar elevation angles (SEA) of about 30° and 40°, respectively. Conclusion The protection of some anatomical sites such as the eye from high UV exposure should not be focused solely on the periods before and after noon, especially in the places and seasons with high SEA.
文摘Treatment of type 1 diabetes mellitus has always posed a challenge to balance hyperglycemia control with hypoglycemia episodes. The quest for newer therapies is continuing and this review attempts to outline the recent developments. The insulin molecule itself has got moulded into different analogues by minor changes in its structure to ensure well controlled delivery, stable half-lives and lesser side effects. Insulin delivery systems have also consistently undergone advances from subcutaneous injections to continuous infusion to trials of inhalational delivery. Continuous glucose monitoring systems are also becoming more accurate and user friendly. Smartphones have also made their entry into therapy of diabetes by integrating blood glucose levels and food intake with calculated adequate insulin required. Artificial pancreas has enabled to a certain extent to close the loop between blood glucose level and insulin delivery with devices armed with meal and exercise announcements, dual hormone delivery and pramlintide infusion. Islet, pancreas-kidney and stem cells transplants are also being attempted though complete success is still a far way off. Incorporating insulin gene and secretary apparatus is another ambitious leap to achieve insulin independence though the search for the ideal vector and target cell is still continuing. Finally to stand up to the statement, prevention is better than cure, immunological methods are being investigated to be used as vaccine to prevent the onset of diabetes mellitus.
文摘AIM:To determine whether bispectral index (BIS) monitoring is useful for propofol administration for deep sedation during endoscopic retrograde cholangiopancreatography (ERCP). METHODS:Fifty-nine consecutive patients with a variety of reasons for ERCP who underwent the procedure at least twice between 1 July 2010 and 30 November 2010. This was a randomized cross-over study, in which each patient underwent ERCP twice, once with BIS monitoring and once with control monitoring. Whether BIS monitoring was done during the first or second ERCP procedure was random. Patients were intermittently administered a mixed regimen including midazolam, pethidine, and propofol by trained nurses. The nurse used a routine practice to monitor sedation using the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scale or the BIS monitoring. The total amount of midazolam and propofol used and serious side effects were compared between the BIS and control groups. RESULTS:The mean total propofol dose administered was 53.1 ± 32.2 mg in the BIS group and 54.9 ± 30.8 mg in the control group (P = 0.673). The individual propofol dose received per minute during the ERCP procedure was 2.90 ± 1.83 mg/min in the BIS group and 3.44 ± 2.04 mg in the control group (P = 0.103). The median value of the MOAA/S score during the maintenance phase of sedation was comparable for the two groups. The mean BIS values throughout the procedure (from insertion to removal of the endoscope) were 76.5 ± 8.7 for all 59 patients in using the BIS monitor. No significant differences in the frequency of < 80% oxygen saturation, hypotension (< 80 mmHg), or bradycardia (< 50 beats/min) were observed between the two study groups. Four cases of poor cooperation occurred, in which the procedure should be stopped to add the propofol dose. After adding the propofol, the procedure could be conducted successfully (one case in the BIS group, three cases in the control group). The endoscopist rated patient sedation as excellent for all patients in both groups. All
基金supported by the National Natural Science Foundation of China(No.11605262)
文摘Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations.In this paper,to check the offset from the mechanical to electrical center in low temperature(77 K),Fourier's law and finite element method are used to simulate cryo-deformation.Laser tracker and micro-alignment telescope are employed in combined BPM calibration,installation and monitoring.The calibration error is<0.02 mm,and the installation and monitoring precision are 0.06 mm and 0.01 mm,respectively.The monitored cryo-deformation agrees well with the simulation results.These indicate that the combined alignment can improve performance of the BPM system.All these guaranteed the success of running the 9.55 MeV@2.14 mA cw protons.