This paper presents a novel mixed-voltage I/O buffer without an extra dual-oxide CMOS process.This mixed-voltage I/O buffer with a simplified circuit scheme can overcome the problems of leakage current and gateoxide r...This paper presents a novel mixed-voltage I/O buffer without an extra dual-oxide CMOS process.This mixed-voltage I/O buffer with a simplified circuit scheme can overcome the problems of leakage current and gateoxide reliability that the conventional CMOS I/O buffer has.The design is realized in a 0.13-μm CMOS process and the simulation results show a good performance increased by ~34% with respect to the product of power consumption and speed.展开更多
混压同塔四回线路运行中因弱电强磁导致线路保护不正确动作的现象时有发生,同时混压同塔四回线跨电压故障影响系统的安全稳定运行。对弱电强磁系统的跨电压故障进行故障分析对电力系统的继电保护配置和整定有着重要意义。该文着眼于整...混压同塔四回线路运行中因弱电强磁导致线路保护不正确动作的现象时有发生,同时混压同塔四回线跨电压故障影响系统的安全稳定运行。对弱电强磁系统的跨电压故障进行故障分析对电力系统的继电保护配置和整定有着重要意义。该文着眼于整个系统,提出统一2个电压等级系统的零序等效网络图,并根据混压同塔四回线跨电压故障时2个双回线系统边界条件的相同点,将2个双回线系统的复合序网络图进行扩展,得到统一两系统的改进复合序网图。在此基础上得到各种不同故障类型下故障电流的正、负、零序分量计算方法,此结果可以直接用于各序分量构成的继电保护原理的计算,计算量小,物理意义明确,工程应用价值高。利用PSCAD软件对一500 k V/220 k V同塔四回线路不同类型故障进行了仿真,验证结果证明了理论分析的正确性。展开更多
混压同塔四回线易发跨电压故障。对方向或距离纵联保护而言,故障选相非常重要。以弱电强磁的混压同塔四回线系统中单相跨单相接地故障为例,提出了一种将混压同塔四回线路进行完全解耦的复合序网图故障分析方法,并分析在此工况下与实际...混压同塔四回线易发跨电压故障。对方向或距离纵联保护而言,故障选相非常重要。以弱电强磁的混压同塔四回线系统中单相跨单相接地故障为例,提出了一种将混压同塔四回线路进行完全解耦的复合序网图故障分析方法,并分析在此工况下与实际中所用的简化计算方法下相电流差突变量之间的差异,最后得到相电流差突变量选相适应性与两系统电源电动势相角之间的关系。分析表明,当电源电动势相角之差在不同的范围内时,相电流差突变量选相适应性不同,给出了不同适应性情况下分别对应的相角范围。最后,利用PSCAD软件建立了一个500 k V/220 k V同塔四回线路模型,验证了理论分析的可靠性。展开更多
目前尚无关于±800 k V与±500 k V同塔混压双回直流输电线路导线选型的可参考研究成果。为此,从电磁环境要求出发,采用电力线法、国际无线电干扰特别委员会(CISPR)和美国邦维尔电力局(BPA)经验公式法等国际公认且广泛使用的计...目前尚无关于±800 k V与±500 k V同塔混压双回直流输电线路导线选型的可参考研究成果。为此,从电磁环境要求出发,采用电力线法、国际无线电干扰特别委员会(CISPR)和美国邦维尔电力局(BPA)经验公式法等国际公认且广泛使用的计算方法,研究了4种导线布置方式下不同导线型号组合的电磁环境指标(包括导线表面电场强度、电晕损耗、地面合成电场强度和离子流密度分布、可听噪声和无线电干扰等)。研究结果表明可听噪声是不同海拔高度下导线选型的主要控制因素。经技术经济比较后选择±500 k V导线在下层的导线布置方式,基于该导线布置方式推荐海拔高度为0 m时±800 k V与±500 k V导线分别采用6×LGJ-630/45和4×LGJ-720/50型号,而海拔高度超过1 000 m时同极异侧布置方式下的±800 k V导线截面积需增大至6×720/50型号。展开更多
混压同塔输电线路可分为完全同塔和部分同塔两大类。由于其特殊的架设方式,跨电压故障时有发生。该文基于复故障分析法,针对部分同塔情况(完全同塔可视为其中一个特例),提出了一种新的跨电压故障短路电流计算方法。首先,将跨电压故障等...混压同塔输电线路可分为完全同塔和部分同塔两大类。由于其特殊的架设方式,跨电压故障时有发生。该文基于复故障分析法,针对部分同塔情况(完全同塔可视为其中一个特例),提出了一种新的跨电压故障短路电流计算方法。首先,将跨电压故障等效为系统发生复故障,通过网络等效化简,可得各序等效二端口网络;其次,选定故障基准相,针对不同的跨电压故障情况,分析其边界条件,并分解为基准相的对称序分量;进一步,根据复故障中两特殊相与基准相的差异,利用两组移相变压器连接各序二端口网络,得到跨电压故障下的系统复合序网,并据此求解短路电流。最后,在PSCAD中搭建500 k V/220 k V混压部分同塔双回线模型,仿真验证该方法的准确性。展开更多
文摘This paper presents a novel mixed-voltage I/O buffer without an extra dual-oxide CMOS process.This mixed-voltage I/O buffer with a simplified circuit scheme can overcome the problems of leakage current and gateoxide reliability that the conventional CMOS I/O buffer has.The design is realized in a 0.13-μm CMOS process and the simulation results show a good performance increased by ~34% with respect to the product of power consumption and speed.
文摘混压同塔四回线路运行中因弱电强磁导致线路保护不正确动作的现象时有发生,同时混压同塔四回线跨电压故障影响系统的安全稳定运行。对弱电强磁系统的跨电压故障进行故障分析对电力系统的继电保护配置和整定有着重要意义。该文着眼于整个系统,提出统一2个电压等级系统的零序等效网络图,并根据混压同塔四回线跨电压故障时2个双回线系统边界条件的相同点,将2个双回线系统的复合序网络图进行扩展,得到统一两系统的改进复合序网图。在此基础上得到各种不同故障类型下故障电流的正、负、零序分量计算方法,此结果可以直接用于各序分量构成的继电保护原理的计算,计算量小,物理意义明确,工程应用价值高。利用PSCAD软件对一500 k V/220 k V同塔四回线路不同类型故障进行了仿真,验证结果证明了理论分析的正确性。
文摘混压同塔四回线易发跨电压故障。对方向或距离纵联保护而言,故障选相非常重要。以弱电强磁的混压同塔四回线系统中单相跨单相接地故障为例,提出了一种将混压同塔四回线路进行完全解耦的复合序网图故障分析方法,并分析在此工况下与实际中所用的简化计算方法下相电流差突变量之间的差异,最后得到相电流差突变量选相适应性与两系统电源电动势相角之间的关系。分析表明,当电源电动势相角之差在不同的范围内时,相电流差突变量选相适应性不同,给出了不同适应性情况下分别对应的相角范围。最后,利用PSCAD软件建立了一个500 k V/220 k V同塔四回线路模型,验证了理论分析的可靠性。
文摘目前尚无关于±800 k V与±500 k V同塔混压双回直流输电线路导线选型的可参考研究成果。为此,从电磁环境要求出发,采用电力线法、国际无线电干扰特别委员会(CISPR)和美国邦维尔电力局(BPA)经验公式法等国际公认且广泛使用的计算方法,研究了4种导线布置方式下不同导线型号组合的电磁环境指标(包括导线表面电场强度、电晕损耗、地面合成电场强度和离子流密度分布、可听噪声和无线电干扰等)。研究结果表明可听噪声是不同海拔高度下导线选型的主要控制因素。经技术经济比较后选择±500 k V导线在下层的导线布置方式,基于该导线布置方式推荐海拔高度为0 m时±800 k V与±500 k V导线分别采用6×LGJ-630/45和4×LGJ-720/50型号,而海拔高度超过1 000 m时同极异侧布置方式下的±800 k V导线截面积需增大至6×720/50型号。
文摘混压同塔输电线路可分为完全同塔和部分同塔两大类。由于其特殊的架设方式,跨电压故障时有发生。该文基于复故障分析法,针对部分同塔情况(完全同塔可视为其中一个特例),提出了一种新的跨电压故障短路电流计算方法。首先,将跨电压故障等效为系统发生复故障,通过网络等效化简,可得各序等效二端口网络;其次,选定故障基准相,针对不同的跨电压故障情况,分析其边界条件,并分解为基准相的对称序分量;进一步,根据复故障中两特殊相与基准相的差异,利用两组移相变压器连接各序二端口网络,得到跨电压故障下的系统复合序网,并据此求解短路电流。最后,在PSCAD中搭建500 k V/220 k V混压部分同塔双回线模型,仿真验证该方法的准确性。