期刊文献+
共找到16,160篇文章
< 1 2 250 >
每页显示 20 50 100
Mathematic principles of interrupted-sampling repeater jamming (ISRJ) 被引量:59
1
作者 WANG XueSong LIU JianCheng ZHANG WenMing FU QiXiang LIU Zhong XIE XiaoXia 《Science in China(Series F)》 2007年第1期113-123,共11页
Coherent Jamming is one of the Important trends in modern radar electronic warfare. High-speed sampling of wldeband radio frequency (RF) signals and high isolatlon of two receive-transmit antennas are key technologi... Coherent Jamming is one of the Important trends in modern radar electronic warfare. High-speed sampling of wldeband radio frequency (RF) signals and high isolatlon of two receive-transmit antennas are key technologies for the realization of coherent jamming. However, these technologies present significant challenges to enginserlng application. In this paper, a novel repeater Jamming based on interrupted sampling technique is presented. For a Jammer with a receive-transmit time-sharing antenna, a radar signal is sampled with a low rate by the jammer. Then, a train of false targets will be achieved after the Jamming signal feed the matched flltar of a pulse compression radar. For the case of the Ilnser frequency modulated (LFM) pulse compression radars, mathematic principles of the interrupted.sampiing repeater jamming Is developed, and then the efficiency of the jamming is described and stated as expressions of key parameters which are also beneficial to the Jamming design for other coherent radars. 展开更多
关键词 interrupted-sampling repeater jamming ambiguity function pulse compression linear frequency modulated signal
原文传递
Volumetric-modulated arc therapy vs c-IMRT in esophageal cancer:A treatment planning comparison 被引量:35
2
作者 Li Yin Hao Wu +8 位作者 Jian Gong Jian-Hao Geng Fan Jiang An-Hui Shi Rong Yu Yong-Heng Li Shu-Kui Han Bo Xu Guang-Ying Zhu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第37期5266-5275,共10页
AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC ... AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT 展开更多
关键词 Esophageal cancer Treatment planning Intensity modulated radiotherapy Volumetric modulat-ed arc radiotherapy Normal tissue complication prob-ability
下载PDF
基于Watson视觉感知模型的能量调制水印算法 被引量:16
3
作者 凌贺飞 卢正鼎 +1 位作者 邹复好 李瑞轩 《软件学报》 EI CSCD 北大核心 2006年第5期1124-1132,共9页
提出一种具有大容量、低复杂性的鲁棒水印算法,主要适合于(但不局限于)JPEG图像和MPEG视频流的实时水印嵌入与检测,因为该算法直接运行于DCT(discretecosinetransform)块数据上.算法主要通过在感知范围内修改DCT块的中低频系数来调制块... 提出一种具有大容量、低复杂性的鲁棒水印算法,主要适合于(但不局限于)JPEG图像和MPEG视频流的实时水印嵌入与检测,因为该算法直接运行于DCT(discretecosinetransform)块数据上.算法主要通过在感知范围内修改DCT块的中低频系数来调制块能量.在能量调制过程中,利用Watson视觉感知模型推导出一条准则,用于限制DCT系数的修改幅度.该系统具有较大的水印容量,可实现在512×512图像中嵌入2048比特.实验表明,算法不仅具有较好的透明性,而且对一些常见的攻击(如高斯噪声、低通滤波、JPEG压缩、增减亮度等)和部分几何攻击(如线性偏移、剪切等)具有较好的鲁棒性. 展开更多
关键词 数字水印 能量调制水印(energy modulated watermarking简称EMW) Watson视觉感知模型 离散余弦变换(discrete COSINE transorm简称DCT)
下载PDF
Frequency modulated weak signal detection based on stochastic resonance and genetic algorithm 被引量:17
4
作者 XING Hongyan LU Chunxia ZHANG Qiang 《Instrumentation》 2016年第1期41-49,共9页
Stochastic resonance system is subject to the restriction of small frequency parameter in weak signal detection,in order to solve this problem,a frequency modulated weak signal detection method based on stochastic res... Stochastic resonance system is subject to the restriction of small frequency parameter in weak signal detection,in order to solve this problem,a frequency modulated weak signal detection method based on stochastic resonance and genetic algorithm is presented in this paper. The frequency limit of stochastic resonance is eliminated by introducing carrier signal,which is multiplied with the measured signal to be injected in the stochastic resonance system,meanwhile,using genetic algorithm to optimize the carrier signal frequency,which determine the generated difference-frequency signal in the lowfrequency range,so as to achieve the stochastic resonance weak signal detection. Results showthat the proposed method is feasible and effective,which can significantly improve the output SNR of stochastic resonance,in addition,the system has the better self-adaptability,according to the operation result and output phenomenon,the unknown frequency of the signal to be measured can be obtained,so as to realize the weak signal detection of arbitrary frequency. 展开更多
关键词 stochastic RESONANCE two-dimension DUFFING OSCILLATOR frequency modulated GENETIC algorithm
下载PDF
On Multi-Timescale Variability of Temperature in China in Modulated Annual Cycle Reference Frame 被引量:16
5
作者 钱诚 Zhaohua WU +1 位作者 符淙斌 周天军 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2010年第5期1169-1182,共14页
The traditional anomaly (TA) reference frame and its corresponding anomaly for a given data span changes with the extension of data length. In this study, the modulated annual cycle (MAC), instead of the widely us... The traditional anomaly (TA) reference frame and its corresponding anomaly for a given data span changes with the extension of data length. In this study, the modulated annual cycle (MAC), instead of the widely used climatological mean annual cycle, is used as an alternative reference frame for computing climate anomalies to study the multi-timescale variability of surface air temperature (SAT) in China based on homogenized daily data from 1952 to 2004. The Ensemble Empirical Mode Decomposition (EEMD) method is used to separate daily SAT into a high frequency component, a MAC component, an interannual component, and a decadal-to-trend component. The results show that the EEMD method can reflect historical events reasonably well, indicating its adaptive and temporally local characteristics. It is shown that MAC is a temporally local reference frame and will not be altered over a particular time span by an exten-sion of data length, thereby making it easier for physical interpretation. In the MAC reference frame, the low frequency component is found more suitable for studying the interannual to longer timescale variability (ILV) than a 13-month window running mean, which does not exclude the annual cycle. It is also better than other traditional versions (annual or summer or winter mean) of ILV, which contains a portion of the annual cycle. The analysis reveals that the variability of the annual cycle could be as large as the magnitude of interannual variability. The possible physical causes of different timescale variability of SAT in China are further discussed. 展开更多
关键词 modulated annual cycle the Ensemble Empirical Mode Decomposition climate anomaly climate normal variability of surface air temperature in China
下载PDF
Trends in Temperature Extremes in Association with Weather-Intraseasonal Fluctuations in Eastern China 被引量:15
6
作者 钱诚 严中伟 +1 位作者 符淙斌 涂锴 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2011年第2期297-309,共13页
Trends in the frequencies of four temperature extremes (the occurrence of warm days, cold days, warm nights and cold nights) with respect to a modulated annual cycle (MAC), and those associated exclusively with we... Trends in the frequencies of four temperature extremes (the occurrence of warm days, cold days, warm nights and cold nights) with respect to a modulated annual cycle (MAC), and those associated exclusively with weather-intraseasonal fluctuations (WIF) in eastern China were investigated based on an updated homogenized daily maximum and minimum temperature dataset for 1960–2008. The Ensemble Empirical Mode Decomposition (EEMD) method was used to isolate the WIF, MAC, and longer-term components from the temperature series. The annual, winter and summer occurrences of warm (cold) nights were found to have increased (decreased) significantly almost everywhere, while those of warm (cold) days have increased (decreased) in northern China (north of 40°N). However, the four temperature extremes associated exclusively with WIF for winter have decreased almost everywhere, while those for summer have decreased in the north but increased in the south. These characteristics agree with changes in the amplitude of WIF. In particular, winter WIF of maximum temperature tended to weaken almost everywhere, especially in eastern coastal areas (by 10%–20%); summer WIF tended to intensify in southern China by 10%–20%. It is notable that in northern China, the occurrence of warm days has increased, even where that associated with WIF has decreased significantly. This suggests that the recent increasing frequency of warm extremes is due to a considerable rise in the mean temperature level, which surpasses the effect of the weakening weather fluctuations in northern China. 展开更多
关键词 climate extremes EEMD weather-intraseasonal fluctuations modulated annual cycle global warming
下载PDF
Surface Modification With Zinc and Zn-Ni Alloy Compositionally Modulated Multilayer Coatings 被引量:15
7
作者 FEI Jing-yin LIANG Guo-zheng XIN Wen-li WANG Wei-kang 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2006年第4期61-67,共7页
Zinc and Zn-Ni alloy compositionally modulated multilayer (CMM) coatings were electrodeposited on to a steel substrate by the successive deposition of zinc and Zn-Ni alloy sublayers from dual baths. The coated sampl... Zinc and Zn-Ni alloy compositionally modulated multilayer (CMM) coatings were electrodeposited on to a steel substrate by the successive deposition of zinc and Zn-Ni alloy sublayers from dual baths. The coated samples were evaluated in terms of the surface appearance, surface and cross-sectional morphologies, as well as corrosion resistance. The microstructural characteristics that were examined using the field emission gun scanning electron microscopy (FEGSEM) confirmed the layered structure, grain refinement of the zinc and Zn-Ni alloy CMM coatings, and revealed the existence of microcracks caused by the internal stress in the thick Zn-Ni alloy sublayers. The corrosion resistance that was evaluated by means of the salt spray test shows that the zinc and Zn-Ni alloy CMM coatings were more corrosion-resistant than the monolithic coatings of zinc or Zn-Ni alloy of the same thickness. The possible reasons for the better protective performance of Zn-Ni/Zn CMM coatings were given on the basis of the analysis on the micrographic features of zinc and Zn-Ni alloy CMM eoatings after the corrosion test. A probable corrosion mechanism of zinc and Zn-Ni alloy CMM coatings was also proposed. 展开更多
关键词 ELECTRODEPOSITION compositionally modulated multilayer coating Zn-Ni alloy corrosion resistance
下载PDF
Role of radiation therapy in gastric adenocarcinoma 被引量:15
8
作者 Lisa Hazard John O'Connor Courtney Scaife 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第10期1511-1520,共10页
Outcomes in patients with gastric cancer in the United States remain disappointing, with a five-year overall survival rate of approximately 23%. Given high rates of local-regional control following surgery, a strong r... Outcomes in patients with gastric cancer in the United States remain disappointing, with a five-year overall survival rate of approximately 23%. Given high rates of local-regional control following surgery, a strong rationale exists for the use of adjuvant radiation therapy. Randomized trials have shown superior local control with adjuvant radiotherapy and improved overall survival with adjuvant chemoradiation. The benefit of adjuvant chemoradiation in patients who have undergone D2 lymph node dissection by an experienced surgeon is not known, and the benefit of adjuvant radiation therapy in addition to adjuvant chemotherapy continues to be defined. In unresectable disease, chemoradiation allows long-term survival in a small number of patients and provides effective palliation. Most trials show a benefit to combined modality therapy compared to chemotherapy or radiation therapy alone. The use of pre-operative, intra-operative, 3D conformal, and intensity modulated radiation therapy in gastric cancer is promising but requires further study. The current article reviews the role of radiation therapy in the treatment of resectable and unresectable gastric carcinoma, focusing on current recommendations in the United States. 展开更多
关键词 Radiation therapy Gastric cancer Stomach cancer CHEMORADIATION Adjuvant therapy Neoadjuvant therapy Intra-operative radiation therapy 3D conformal radiation therapy Intensity modulated radiation therapy
下载PDF
Simultaneous modulated accelerated radiation therapy for esophageal cancer:A feasibility study 被引量:12
9
作者 Wu-Zhe Zhang Jian-Zhou Chen +6 位作者 De-Rui Li Zhi-Jian Chen Hong Guo Ting-Ting Zhuang Dong-Sheng Li Ming-Zhen Zhou Chuang-Zhen Chen 《World Journal of Gastroenterology》 SCIE CAS 2014年第38期13973-13980,共8页
AIM: To establish the feasibility of simultaneous modulated accelerated radiation therapy (SMART) in esophageal cancer (EC).
关键词 Simultaneous modulated accelerated radiation therapy Three-dimensional conformal radiotherapy Intensity-modulated radiation therapy Esophageal cancer FEASIBILITY
下载PDF
The Role of Changes in the Annual Cycle in Earlier Onset of Climatic Spring in Northern China 被引量:13
10
作者 钱诚 符淙斌 严中伟 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2011年第2期284-296,共13页
Climatic changes in the onset of spring in northern China associated with changes in the annual cycle and with a recent warming trend were quantified using a recently developed adaptive data analysis tool, the Ensembl... Climatic changes in the onset of spring in northern China associated with changes in the annual cycle and with a recent warming trend were quantified using a recently developed adaptive data analysis tool, the Ensemble Empirical Mode Decomposition. The study was based on a homogenized daily surface air temperature (SAT) dataset for the period 1955–2003. The annual cycle here is referred to as a refined modulated annual cycle (MAC). The results show that spring at Beijing has arrived significantly earlier by about 2.98 d (10 yr)-1, of which about 1.85 d (10 yr)-1 is due to changes in the annual cycle and 1.13 d (10 yr)-1 due to the long-term warming trend. Variations in the MAC component explain about 92.5% of the total variance in the Beijing daily SAT series and could cause as much as a 20-day shift in the onset of spring from one year to another. The onset of spring has been advancing all over northern China, but more significant in the east than in the west part of the region. These differences are somehow unexplainable by the zonal pattern of the warming trend over the whole region, but can be explained by opposite changes in the spring phase of the MAC, i.e. advancing in the east while delaying in the west. In the east of northern China, the change in the spring phase of MAC explains 40%–60% of the spring onset trend and is attributable to a weakening Asian winter monsoon. The average sea level pressure in Siberia (55°–80°N, 50°–110°E), an index of the strength of the winter monsoon, could serve as a potential short-term predictor for the onset of spring in the east of northern China. 展开更多
关键词 spring onset Ensemble Empirical Mode Decomposition modulated annual cycle Asian winter monsoon global warming
下载PDF
医科达Precise直线加速器iViewGT系统故障分析及维修 被引量:13
11
作者 陈浩 林丹凤 +1 位作者 李玉琼 严潭 《中国医学装备》 2015年第9期132-133,共2页
瑞典医科达公司的Precise直线加速器是一款设计精细、全数字化控制的加速器,配备40对MLC(多叶光阑)[1]。其中利用i View GT电子影像验证系统,可开展普通放射治疗、立体定向放射治疗及适形调强放射治疗(intensity modulated radiation... 瑞典医科达公司的Precise直线加速器是一款设计精细、全数字化控制的加速器,配备40对MLC(多叶光阑)[1]。其中利用i View GT电子影像验证系统,可开展普通放射治疗、立体定向放射治疗及适形调强放射治疗(intensity modulated radiation therapy,IMRT),高分辨率的影像质量保证了投照剂量得到实时验证,以满足不同患者的治疗需要[2]。 展开更多
关键词 医科达 直线加速器 PRECISE iViewGT 放射治疗 影像质量 modulated 系统故障分析 验证系统 全数字化控制
下载PDF
Multi-component LFM signal detection and parameter estimation based on Radon-HHT 被引量:9
12
作者 Chen Wenwu Chen Rushan 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第6期1097-1101,共5页
A new method is proposed to analyze multi-component linear frequency modulated (LFM) signals, which eliminates cross terms in conventional Wigner-Ville distribution (WVD). The approach is based on Radon transform ... A new method is proposed to analyze multi-component linear frequency modulated (LFM) signals, which eliminates cross terms in conventional Wigner-Ville distribution (WVD). The approach is based on Radon transform and Hilbert-Huang transform (HHT), which is a recently developed method adaptive to non-linear and non-stationary signals. The complicated signal is decomposed into several intrinsic mode functions (IMF) by the empirical mode decomposition (EMD), which makes the consequent instantaneous frequency meaningful. After the instantaneous frequency and Hilbert spectrum are computed, multi-component LFM signals detection and parameter estimation are obtained using Radon transform on the Hilbert spectrum plane. The simulation results show its feasibility and effectiveness. 展开更多
关键词 linear frequency modulated empirical mode decomposition Hilbert-Huang transform Hilbert spectrum.
下载PDF
Dosimetry Comparison between Volumetric Modulated Arc Therapy with RapidArc and Fixed Field Dynamic IMRT for Local-Regionally Advanced Nasopharyngeal Carcinoma 被引量:7
13
作者 Bao-min Zheng Xiao-xia Dong +3 位作者 Hao Wu You-jia Duan Shu-kui Han Yan Sun 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2011年第4期259-264,共6页
Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 p... Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 patients of locally advanced NPC were selected randomly. The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients. The dosimetry of the planning target volumes (PTV), the organs at risk (OARs) and the healthy tissue were evaluated. The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions. Each fraction applied daily, five fractions per week. The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency. Results: Both techniques had reached clinical treatment’s requirement. The mean dose (Dmean), maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy, 74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy, 73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05), respectively. Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT. The conformity index (CI: 95%) was 0.78±0.01 for both techniques (P>0.05). Compared to IMRT, RapidArc allowed a reduction of Dmean to the brain stem, mandible and optic nerves of 14.1% (P<0.05), 5.6% (P<0.05) and 12.2% (P<0.05), respectively. For the healthy tissue and the whole absorbed dose, Dmean of RapidArc was reduced by 3.6% (P<0.05), and 3.7% (P<0.05), respectively. The Dmean to the parotids, the spinal cord and the lens had no statistical difference among them. The mean MU values of RapidArc and IMRT were 550 and 1,379. The mean treatment time of RapidArc and IMRT was 165 s and 447 s. Compared to IMRT, the delivery time and the MU values of RapidArc were reduced by 63% and 60%, respectively. Conclusion: For locally advanced NPC, both RapidArc and IMRT reached the clinic requirement. The target volume 展开更多
关键词 Volumetric modulated arc therapy Intensity-modulated radiotherapy DOSIMETRY Target volume Nasopharyngeal carcinoma
下载PDF
NUMERICAL SIMULATION OF FLOW FIELD BETWEEN FRICTIONAL PAIRS IN HYDROVISCOUS DRIVE SURFACE 被引量:8
14
作者 HUANG Jiahai QIU Minxiu LIAO Lingling FU Linjian 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第3期72-75,共4页
The flow field of the oil film between frictional pairs in the hydroviscous drive test rig is investigated. A three-dimensional Navier-Stokes(N-S) equation considering viscous force and inertial force rather than Re... The flow field of the oil film between frictional pairs in the hydroviscous drive test rig is investigated. A three-dimensional Navier-Stokes(N-S) equation considering viscous force and inertial force rather than Reynolds equation or modified Reynolds equation is presented to model the flow field. Pressure and temperature distribution in radial and circumferential direction under three different conditions, i.e., isothermal, that considering viscosity-temperature characteristic as well as shear thinning non-Newtonian fluid are simulated, respectively, by utilizing the commercial computational fluid dynamics(CFD) software FLUENT. The results reveal that the grooves on the driven plate make the pressure, temperature distribution present periodic variation. The oil temperature and shear rate have important effects on the flow field between frictional pairs, and the oil temperature is more important parameter. The simulation results lay a theoretical foundation for the reasonable designs ofhydroviscous drive. 展开更多
关键词 Hydroviscous drive modulated clutch Frictional plates Numerical simulation
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
15
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy Intensity modulated radiation therapy TOXICITY Helical tomotherapy Volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Energy Absorption by the Membrane Rafts in the Modulated Electro-Hyperthermia (mEHT) 被引量:7
16
作者 Edina Papp Tamás Vancsik +1 位作者 Eva Kiss Oliver Szasz 《Open Journal of Biophysics》 2017年第4期216-229,共14页
Aim: Heating by nanoparticles, which are located in the tissue to be treated, is a well-recognized method in hyperthermic oncology. Our objective is to investigate selective, nanoscopic heating without concentrating e... Aim: Heating by nanoparticles, which are located in the tissue to be treated, is a well-recognized method in hyperthermic oncology. Our objective is to investigate selective, nanoscopic heating without concentrating extra artificial nanoparticles. We have in silico calculation to study the heating of the transmembrane protein clusters (rafts) on cell-membrane. The transmembrane protein domains have significantly higher dielectric constant than their lipid neighborhood in the membrane. This difference causes a local gradient in the Specific Absorption Rate (SAR), which could be a factor of heating of the membranes locally, as well as exciting the receptors for various signal transduction in the cells. We suppose that this process determines the observed cellular effects of modulated electro-hyperthermia (mEHT, trade-name: oncothermia). Materials and Methods: In silico models with highly specialized software (Computer Simulation Technology (CST), Darmstadt, Germany) were performed visualizing the selectivity for the membrane domains. Local raft models were created to simulate the electromagnetic (EM) effect of a 13.56 MHz excitation between two perfect electrical conductor plates, simulating the equipotential conditions of the sides of the membrane in the vicinity of the raft. The simulations were performed with near-field (EQS) solver of CST. The electric field, current density, and electric loss density were monitored by the simulations. The applied material properties and parameters refer to the recent literature. Results: In silico models show ten times higher energy-absorption of the transmembrane domains than that of its lipid-membrane surrounding, and intra- and extracellular neighborhood. Depending on the size, orientation, and location of the membrane rafts, the value of SAR varies, but we use only two simplified models to see the absorption properties. Taking into account the characteristics of the EM field effects we showed that the selective energy-absorption increased further by the cell-cell interacti 展开更多
关键词 modulated Electro-Hyperthermia (mEHT) Nanoheating Membrane Raft Selection
下载PDF
Ni-based Ni-Fe-B-Si-Ta bulk metallic glasses 被引量:5
17
作者 ZHU ChunLei1, WANG Qing1, ZHAO YaJun1, WANG YingMin1, QIANG JianBing1 & DONG Chuang1,21 Key Lab of Materials Modification (Ministry of Education), School of Materials Science and Engineering, Dalian University of Technology, Dalian 116024, China 2 International Center for Materials Physics, Chinese Academy of Sciences, Shenyang 110016, China 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2010年第3期440-444,共5页
The glass-forming ability and properties of Ni-based Ni-Fe-B-Si-Ta bulk metallic glasses are explored in this work. The alloy compositions are determined by using a combination of the cluster line approach, the multi-... The glass-forming ability and properties of Ni-based Ni-Fe-B-Si-Ta bulk metallic glasses are explored in this work. The alloy compositions are determined by using a combination of the cluster line approach, the multi-alloying strategy and the substitutions of similar elements. Bulk metallic glasses with diameters of 3 mm take shape at compositions formulated under the clus- ter-plus-glue-atom model [M9B]B~[(Ni1-xFex)7.71(Si0.66Ta0.34)1.29B]B0.94=(Ni1-xFex)70.5B17.7Si7.8Ta4, x=0.35–0.45, where the bracketed part is the cluster and the unbracketed part is the glue atoms. These alloys exhibit good magnetic properties. The maximum Is is found in the (Ni0.55Fe0.45)70.5B17.7Si7.8Ta4 alloy which reaches 0.51 T, with its Hc as low as 8.5 A/m. Interestingly, these alloys display dual glass transitions at (Ni0.65Fe0.35)70.5B17.7Si7.8Ta4, (Ni0.60Fe0.4)70.5B17.7Si7.8Ta4 and (Ni0.55Fe0.45)70.5B17.7- Si7.8Ta4 as unveiled by Temperature-Modulated Differential Scanning Calorimetry. 展开更多
关键词 bulk metallic GLASSES cluster Ni-Fe-based alloys modulated Differential Scanning CALORIMETRY
原文传递
Simultaneous range and radial velocity estimation with a single narrowband LFM pulse 被引量:6
18
作者 Chunmao Yeh Jian Yang +1 位作者 Xiuming Shan Yingning Peng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2012年第3期372-377,共6页
The mismatch effect induced by the radial motion of a target is analyzed for linear frequency modulated (LFM) signals. Then, a novel integrated processing scheme is proposed to re- solve the delay-Doppler coupling e... The mismatch effect induced by the radial motion of a target is analyzed for linear frequency modulated (LFM) signals. Then, a novel integrated processing scheme is proposed to re- solve the delay-Doppler coupling effect in LFM pulse compression. Therefore the range and radial velocity of the target can be si- multaneously estimated with a narrowband LFM pulse. Finally, numerical simulation results demonstrate the effectiveness and good performance of the proposed method. 展开更多
关键词 delay-Doppler coupling motion estimation linear fre- quency modulated (LFM) pulse extended filtering.
下载PDF
Wigner-Hough transform based on slice's entropy and its application to multi-LFM signal detection 被引量:6
19
作者 Hongwei Wang Xiangyu Fan +1 位作者 You Chen Yuanzhi Yang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2017年第4期634-642,共9页
To enhance the capacity of the radar-reconnaissance interception receiver recognizing linear frequency modulated (LFM) at a low signal-noise ratio, this paper presents WignerHough transform (WHT) of the LFM signal and... To enhance the capacity of the radar-reconnaissance interception receiver recognizing linear frequency modulated (LFM) at a low signal-noise ratio, this paper presents WignerHough transform (WHT) of the LFM signal and its corresponding characteristics, derives the probability density functions of the LFM signal and Gaussian white noise within WHT based on entropy (WHTE), dimension under different assumptions and puts forward a WHT algorithm based on entropy of slice to improve the capacity of detecting the LFM signal. Entropy of the WHT domain slice is adopted to assess the information size of polar radius or angle slice, which is converted into the weight factor to weight every slice. Double-deck weight is used to weaken the influences of noise and disturbance terms and WHTE treatment and signal detection procedure are also summarized. The rationality of the algorithm is demonstrated through theoretical analysis and formula derivation, the efficiency of the algorithm is verified by simulation comparison between WHT, fractional Fourier transform and periodic WHT, and it is highlighted that the WHTE algorithm has better detection accuracy and range of application against strong noise background. 展开更多
关键词 low signal-to-noise ratio linear frequency modulated signal probability density function Wigner-Hough transform (WHT) signal detection entropy of slice
下载PDF
Current role of modern radiotherapy techniques in the management of breast cancer 被引量:6
20
作者 Gokhan Ozyigit Melis Gultekin 《World Journal of Clinical Oncology》 CAS 2014年第3期425-439,共15页
Breast cancer is the most common type of malignancy in females. Advances in systemic therapies and radiotherapy(RT) provided long survival rates in breast cancer patients. RT has a major role in the management of brea... Breast cancer is the most common type of malignancy in females. Advances in systemic therapies and radiotherapy(RT) provided long survival rates in breast cancer patients. RT has a major role in the management of breast cancer. During the past 15 years several developments took place in the field of imaging and irradiation techniques, intensity modulated RT, hypofractionation and partial-breast irradiation. Currently, improvements in the RT technology allow us a subsequent decrease in the treatment-related complications such as fibrosis and long-term cardiac toxicity while improving the loco-regional control rates and cosmetic results. Thus, it is crucial that modern radiotherapy techniques should be carried out with maximum care and efficiency. Several randomized trials provided evidence for the feasibility of modern radiotherapy techniques in the management of breast cancer. However, the role of modern radiotherapy techniques in the management of breast cancer will continue to be defined by the mature results of randomized trials. Current review will provide an up-to-date evidence based data on the role of modern radiotherapy techniques in the management of breast cancer. 展开更多
关键词 BREAST cancer RADIOTHERAPY Intensity modulated RADIOTHERAPY Partial BREAST IRRADIATION HYPOFRACTIONATION
下载PDF