将小波理论应用于多自由度(MDOF,multi degree of freedom)系统的模态参数的识别中,首先对MD OF系统的响应函数作基于Morlet小波的时频分解,再由小波系数模的局部极大值求得小波脊,最后求出MDOF系统的各阶模态的固有频率及阻尼比.文中...将小波理论应用于多自由度(MDOF,multi degree of freedom)系统的模态参数的识别中,首先对MD OF系统的响应函数作基于Morlet小波的时频分解,再由小波系数模的局部极大值求得小波脊,最后求出MDOF系统的各阶模态的固有频率及阻尼比.文中给出了实例,进行了计算说明,结果表明了该方法的有效性.展开更多
This paper reviews the applications of the multi degree-of-freedom(MDOF)equivalent linear system in seismic analysis and design of planar steel and reinforced concrete framed structures.An equivalent MDOF linear struc...This paper reviews the applications of the multi degree-of-freedom(MDOF)equivalent linear system in seismic analysis and design of planar steel and reinforced concrete framed structures.An equivalent MDOF linear structure,analogous to the original MDOF nonlinear structure,is constructed,which has the same mass and elastic stiffness as the original structure and modal damping ratios that account for the effects of geometrical and material nonlinearities.The equivalence implies a balance between the viscous damping work of the equivalent linear structure and that of the nonlinearities in the original nonlinear structure.This work balance is established with the aid of a transfer function in the frequency domain.Thus,equivalent modal damping ratios can be explicitly determined in terms of the period and deformation levels of the structure as well as the soil types.Use of these equivalent modal damping ratios can help address a variety of seismic analysis and design problems associated with planar steel and reinforced concrete framed structures in a rational and accurate manner.These include force-based seismic design with the aid of acceleration response spectra characterized by high amounts of damping,improved direct displacement-based seismic design and the development of advanced seismic intensity measures.The equivalent modal damping ratios are also utilized in the context of linear modal analysis for the definition and construction of the MDOF response spectrum.Furthermore,the equivalent modal damping ratios are employed in a seismic retrofit method for steel-framed structures with viscous dampers.Finally,it is demonstrated that modal behavior(or strength reduction)factors can be easily constructed based on these modal damping ratios for a more rational and accurate force-based seismic design,including the determination of inelastic displacement profiles.展开更多
In the present study,actual three-dimensional structures are converted into a stick model of multi degree of-freedom(MDOF)systems for understanding the macro-behavior of structures.The study investigates the performan...In the present study,actual three-dimensional structures are converted into a stick model of multi degree of-freedom(MDOF)systems for understanding the macro-behavior of structures.The study investigates the performance of three closely spaced,adjacent G+10,fixed-base MDOF systems with the mass aligned at the same levels and subjected to accidental underground blast loading.The acceleration time history of underground blast loading is generated based on past empirical relationships.The blast charge weight varies from 10 to 75 t while keeping the charge distance constant(R=100 m).The entire formulation is solved with the MATLAB solver,using the state space form solution.Three cases are considered,based on changing the position of the three stick systems.The first case considered left building rigid,middle building moderate rigid,and right building flexible.The second assumed left building flexible,middle building rigid,and right building moderate rigid.The third examined the left building as moderate rigid,the middle building as flexible,and the right building rigid.An analysis of the results shows that the arrangement with low stiffness,high stiffness,and moderately stiff buildings placed to the left,middle,and right side,respectively,yields minimum structural response when compared to the other two combinations.展开更多
基于地震作用下弹塑性SDOF(Single Degree of Freedom)和弹性MDOF(Multi-degree of Freedom)系统能量输入研究,本文分析了弹塑性MDOF系统能量输入规律。以实测地震记录为输入,采用弹塑性时程分析方法,计算了一阶初始周期≤3s的5、10、20...基于地震作用下弹塑性SDOF(Single Degree of Freedom)和弹性MDOF(Multi-degree of Freedom)系统能量输入研究,本文分析了弹塑性MDOF系统能量输入规律。以实测地震记录为输入,采用弹塑性时程分析方法,计算了一阶初始周期≤3s的5、10、20、30层双线性滞回剪切层模型,不同阻尼比、承载力降低系数情况下4800个结构和一阶初始周期>3s的40层结构能量输入,与弹塑性SDOF系统的输入能量谱进行对比。研究表明:一阶周期在3s以内的弹塑性MDOF系统输入能量EI可用相同阻尼比、初始周期、承载力降低系数的弹塑性SDOF系统计算结果近似确定;一阶周期大于3s的弹塑性MDOF系统,可采用MPA方法等效为多个弹塑性SDOF系统,按照振型叠加法计算总输入能。展开更多
Discrete models such as the lumped parameter model and the finite element model are widely used in the solution of soil amplification of earthquakes. However, neither of the models will accurately estimate the natural...Discrete models such as the lumped parameter model and the finite element model are widely used in the solution of soil amplification of earthquakes. However, neither of the models will accurately estimate the natural frequencies of soil deposit, nor simulate a damping of frequency independence. This research develops a new discrete model for onedimensional viscoelastic response analysis of layered soil deposit based on the mode equivalence method. The new discrete model is a one-dimensional equivalent multi-degree-of-freedom(MDOF) system characterized by a series of concentrated masses, springs and dashpots with a special configuration. The dynamic response of the equivalent MDOF system is analytically derived and the physical parameters are formulated in terms of modal properties. The equivalent MDOF system is verified through a comparison of amplification functions with the available theoretical solutions. The appropriate number of degrees of freedom(DOFs) in the equivalent MDOF system is estimated. A comparative study of the equivalent MDOF system with the existing discrete models is performed. It is shown that the proposed equivalent MDOF system can exactly present the natural frequencies and the hysteretic damping of soil deposits and provide more accurate results with fewer DOFs.展开更多
文摘将小波理论应用于多自由度(MDOF,multi degree of freedom)系统的模态参数的识别中,首先对MD OF系统的响应函数作基于Morlet小波的时频分解,再由小波系数模的局部极大值求得小波脊,最后求出MDOF系统的各阶模态的固有频率及阻尼比.文中给出了实例,进行了计算说明,结果表明了该方法的有效性.
文摘This paper reviews the applications of the multi degree-of-freedom(MDOF)equivalent linear system in seismic analysis and design of planar steel and reinforced concrete framed structures.An equivalent MDOF linear structure,analogous to the original MDOF nonlinear structure,is constructed,which has the same mass and elastic stiffness as the original structure and modal damping ratios that account for the effects of geometrical and material nonlinearities.The equivalence implies a balance between the viscous damping work of the equivalent linear structure and that of the nonlinearities in the original nonlinear structure.This work balance is established with the aid of a transfer function in the frequency domain.Thus,equivalent modal damping ratios can be explicitly determined in terms of the period and deformation levels of the structure as well as the soil types.Use of these equivalent modal damping ratios can help address a variety of seismic analysis and design problems associated with planar steel and reinforced concrete framed structures in a rational and accurate manner.These include force-based seismic design with the aid of acceleration response spectra characterized by high amounts of damping,improved direct displacement-based seismic design and the development of advanced seismic intensity measures.The equivalent modal damping ratios are also utilized in the context of linear modal analysis for the definition and construction of the MDOF response spectrum.Furthermore,the equivalent modal damping ratios are employed in a seismic retrofit method for steel-framed structures with viscous dampers.Finally,it is demonstrated that modal behavior(or strength reduction)factors can be easily constructed based on these modal damping ratios for a more rational and accurate force-based seismic design,including the determination of inelastic displacement profiles.
文摘In the present study,actual three-dimensional structures are converted into a stick model of multi degree of-freedom(MDOF)systems for understanding the macro-behavior of structures.The study investigates the performance of three closely spaced,adjacent G+10,fixed-base MDOF systems with the mass aligned at the same levels and subjected to accidental underground blast loading.The acceleration time history of underground blast loading is generated based on past empirical relationships.The blast charge weight varies from 10 to 75 t while keeping the charge distance constant(R=100 m).The entire formulation is solved with the MATLAB solver,using the state space form solution.Three cases are considered,based on changing the position of the three stick systems.The first case considered left building rigid,middle building moderate rigid,and right building flexible.The second assumed left building flexible,middle building rigid,and right building moderate rigid.The third examined the left building as moderate rigid,the middle building as flexible,and the right building rigid.An analysis of the results shows that the arrangement with low stiffness,high stiffness,and moderately stiff buildings placed to the left,middle,and right side,respectively,yields minimum structural response when compared to the other two combinations.
文摘基于地震作用下弹塑性SDOF(Single Degree of Freedom)和弹性MDOF(Multi-degree of Freedom)系统能量输入研究,本文分析了弹塑性MDOF系统能量输入规律。以实测地震记录为输入,采用弹塑性时程分析方法,计算了一阶初始周期≤3s的5、10、20、30层双线性滞回剪切层模型,不同阻尼比、承载力降低系数情况下4800个结构和一阶初始周期>3s的40层结构能量输入,与弹塑性SDOF系统的输入能量谱进行对比。研究表明:一阶周期在3s以内的弹塑性MDOF系统输入能量EI可用相同阻尼比、初始周期、承载力降低系数的弹塑性SDOF系统计算结果近似确定;一阶周期大于3s的弹塑性MDOF系统,可采用MPA方法等效为多个弹塑性SDOF系统,按照振型叠加法计算总输入能。
基金National Natural Science Foundation of China(51208296&51478343)Shanghai Committee of Science and Technology(13231200503)+2 种基金Fundamental Research Funds for the Central Universities(2013KJ095&101201438)Shanghai Educational Development Foundation(13CG17)National Key Technology R&D Program(2012BAK24B04)
文摘Discrete models such as the lumped parameter model and the finite element model are widely used in the solution of soil amplification of earthquakes. However, neither of the models will accurately estimate the natural frequencies of soil deposit, nor simulate a damping of frequency independence. This research develops a new discrete model for onedimensional viscoelastic response analysis of layered soil deposit based on the mode equivalence method. The new discrete model is a one-dimensional equivalent multi-degree-of-freedom(MDOF) system characterized by a series of concentrated masses, springs and dashpots with a special configuration. The dynamic response of the equivalent MDOF system is analytically derived and the physical parameters are formulated in terms of modal properties. The equivalent MDOF system is verified through a comparison of amplification functions with the available theoretical solutions. The appropriate number of degrees of freedom(DOFs) in the equivalent MDOF system is estimated. A comparative study of the equivalent MDOF system with the existing discrete models is performed. It is shown that the proposed equivalent MDOF system can exactly present the natural frequencies and the hysteretic damping of soil deposits and provide more accurate results with fewer DOFs.