Previously we derived equations determining line broadening in ax-ray diffraction profile due to stacking faults. Here, we will consider line broadening due to particle size and strain which are the other factors affe...Previously we derived equations determining line broadening in ax-ray diffraction profile due to stacking faults. Here, we will consider line broadening due to particle size and strain which are the other factors affecting line broadening in a diffraction profile. When line broadening in a diffraction profile is due to particle size and strain, the theoretical model of the sample under study is either a Gaussian or a Cauchy function or a combination of these functions, e.g. Voigt and Pseudovoigt functions. Although the overall nature of these functions can be determined by Mitra’s R(x) test and the Pearson and Hartley x?test, details of a predicted model will be lacking. Development of a mathematical model to predict various parameters before embarking upon the actual experiment would enable correction of significant sources of error prior to calculations. Therefore, in this study, predictors of integral width, Fourier Transform, Second and Fourth Moment and Fourth Cumulant of samples represented by Gauss, Cauchy, Voigt and Pseudovoigt functions have been worked out. An additional parameter, the coefficient of excess, which is the ratio of the Fourth Moment to three times the square of the Second Moment, has been proposed. For a Gaussian profile the coefficient of excess is one, whereas for Cauchy distributions, it is a function of the lattice variable. This parameter can also be used for determining the type of distribution present in aggregates of distorted crystallites. Programs used to define the crystal structure of materials need to take this parameter into consideration.展开更多
A semi-gas kinetics (SGK) model for performance analyses of flowing chemical oxygen-iodine laser (COIL) is presented. In this model, the oxygen-iodine reaction gas flow is treated as a continuous medium, and the effec...A semi-gas kinetics (SGK) model for performance analyses of flowing chemical oxygen-iodine laser (COIL) is presented. In this model, the oxygen-iodine reaction gas flow is treated as a continuous medium, and the effect of thermal motions of particles of different laser energy levels on the performances of the COIL is included and the velocity distribution function equations are solved by using the double-parameter perturbational method. For a premixed flow, effects of different chemical reaction systems, different gain saturation models and temperature, pressure, yield of excited oxygen, iodine concentration and frequency-shift on the performances of the COIL are computed, and the calculated output power agrees well with the experimental data. The results indicate that the power extraction of the SGK model considering 21 reactions is close to those when only the reversible pumping reaction is considered, while different gain saturation models and adjustable parameters greatly affect the output power, the optimal threshold gain range, and the length of power extraction.展开更多
文摘Previously we derived equations determining line broadening in ax-ray diffraction profile due to stacking faults. Here, we will consider line broadening due to particle size and strain which are the other factors affecting line broadening in a diffraction profile. When line broadening in a diffraction profile is due to particle size and strain, the theoretical model of the sample under study is either a Gaussian or a Cauchy function or a combination of these functions, e.g. Voigt and Pseudovoigt functions. Although the overall nature of these functions can be determined by Mitra’s R(x) test and the Pearson and Hartley x?test, details of a predicted model will be lacking. Development of a mathematical model to predict various parameters before embarking upon the actual experiment would enable correction of significant sources of error prior to calculations. Therefore, in this study, predictors of integral width, Fourier Transform, Second and Fourth Moment and Fourth Cumulant of samples represented by Gauss, Cauchy, Voigt and Pseudovoigt functions have been worked out. An additional parameter, the coefficient of excess, which is the ratio of the Fourth Moment to three times the square of the Second Moment, has been proposed. For a Gaussian profile the coefficient of excess is one, whereas for Cauchy distributions, it is a function of the lattice variable. This parameter can also be used for determining the type of distribution present in aggregates of distorted crystallites. Programs used to define the crystal structure of materials need to take this parameter into consideration.
基金supported by the National Natural Science Foundation of China(Grant No.10032050).
文摘A semi-gas kinetics (SGK) model for performance analyses of flowing chemical oxygen-iodine laser (COIL) is presented. In this model, the oxygen-iodine reaction gas flow is treated as a continuous medium, and the effect of thermal motions of particles of different laser energy levels on the performances of the COIL is included and the velocity distribution function equations are solved by using the double-parameter perturbational method. For a premixed flow, effects of different chemical reaction systems, different gain saturation models and temperature, pressure, yield of excited oxygen, iodine concentration and frequency-shift on the performances of the COIL are computed, and the calculated output power agrees well with the experimental data. The results indicate that the power extraction of the SGK model considering 21 reactions is close to those when only the reversible pumping reaction is considered, while different gain saturation models and adjustable parameters greatly affect the output power, the optimal threshold gain range, and the length of power extraction.