A protocol was established for simultaneous measurements of zircon U-Pb ages and trace elements by LA-ICP-MS at spot sizes of 16 32 μm.This was accomplished by introducing N 2 into ICP to increase the sensitivity.The...A protocol was established for simultaneous measurements of zircon U-Pb ages and trace elements by LA-ICP-MS at spot sizes of 16 32 μm.This was accomplished by introducing N 2 into ICP to increase the sensitivity.The obtained U-Pb ages for zircon standards GJ-1,TEMORA and SK10-2 are consistent with the preferred values within about 1% uncertainty (2σ) by simple external calibration against zircon standard 91500.Different data reduction softwares could yield different uncertainties for calculation of U-Pb ages.The commercially available program GLITTER4.4 could apply an improper uncertainty calculation strategy,but it may yield artificial high precisions for single analyses.Our trace element analyses indicate that Si is not an ideal internal standard for zircon when calibrated against the NIST glasses.Calibration against the NIST glasses using Si as an internal standard,a systematic deviation of 10% 30% was found for most trace elements including Zr.However,the trace element compositions of zircon can be accurately measured by calibration against multiple reference materials with natural compositions (e.g.,BCR-2G,BHVO-2G and BIR-1G),or calibration against NIST SRM 610 and using Zr as an internal standard.Analyses of two pieces of GJ-1 demonstrate that it is relatively homogenous for most trace elements (except for Ti).展开更多
Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gab...Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gabbro was carried out on quadrupole ICP-MS equipped with 193 nm excimer laser in 20 μm spot size. The weighted mean 206Pb/238U ages of 91500,GJ1 and TEMORA 1 are 1064.4±4.8 Ma(2σ ),603.2±2.4 Ma(2σ ) and 418.2±2.4 Ma(2σ ),respectively. The relative standard de-viations(RSDs) of 206Pb/238U ages(2σ ) are less than 2.2% for single measurements and 0.6% for weighted means. The obtained weighted mean 206Pb/238U ages of three standard zircons agree with the recommended values within 2σ error. The weighted mean 206Pb/238U age of SK10-2 is 31.42±0.25 Ma(2σ ) and the RSDs of 206Pb/238U ages(2σ ) are between 2.4% and 5.7% for single measurements and less than 0.8% for weighted mean. The obtained weighted mean 206Pb/238U age is in good agreement with the age obtained by Yuan(2004). Trace element concentrations of NIST612 and NIST614 obtained under the same LA-ICP-MS operating conditions agree with the recommended values within analytical error. The results indicate that it is possible to measure U-Pb age and trace elements simultaneously by LA-ICP-MS in a small spot size of 20 μm.展开更多
基金supported by the National Natural Science Foundation of China (GrantNos. 40821061,90914007,40576030 and 90714010)the State Administration of Foreign Expert Affairs of China (Grant No. B07039)the Special Fund for Basic Scientific Research of Central Colleges,China University of Geosciences
文摘A protocol was established for simultaneous measurements of zircon U-Pb ages and trace elements by LA-ICP-MS at spot sizes of 16 32 μm.This was accomplished by introducing N 2 into ICP to increase the sensitivity.The obtained U-Pb ages for zircon standards GJ-1,TEMORA and SK10-2 are consistent with the preferred values within about 1% uncertainty (2σ) by simple external calibration against zircon standard 91500.Different data reduction softwares could yield different uncertainties for calculation of U-Pb ages.The commercially available program GLITTER4.4 could apply an improper uncertainty calculation strategy,but it may yield artificial high precisions for single analyses.Our trace element analyses indicate that Si is not an ideal internal standard for zircon when calibrated against the NIST glasses.Calibration against the NIST glasses using Si as an internal standard,a systematic deviation of 10% 30% was found for most trace elements including Zr.However,the trace element compositions of zircon can be accurately measured by calibration against multiple reference materials with natural compositions (e.g.,BCR-2G,BHVO-2G and BIR-1G),or calibration against NIST SRM 610 and using Zr as an internal standard.Analyses of two pieces of GJ-1 demonstrate that it is relatively homogenous for most trace elements (except for Ti).
基金Supported by the National Natural Science Foundation of China (Grant Nos.40472099, 40521001 and 40673019)Chinese Ministry of Education (Grant Nos.IRT0441 and 306021)
文摘Simultaneous in-situ determination of U-Pb ages and 20 trace elements of three international zircon standards(91500,GJ1 and TEMORA 1) and one laboratory zircon standard(SK10-2) separated from Cenozoic fine-grained gabbro was carried out on quadrupole ICP-MS equipped with 193 nm excimer laser in 20 μm spot size. The weighted mean 206Pb/238U ages of 91500,GJ1 and TEMORA 1 are 1064.4±4.8 Ma(2σ ),603.2±2.4 Ma(2σ ) and 418.2±2.4 Ma(2σ ),respectively. The relative standard de-viations(RSDs) of 206Pb/238U ages(2σ ) are less than 2.2% for single measurements and 0.6% for weighted means. The obtained weighted mean 206Pb/238U ages of three standard zircons agree with the recommended values within 2σ error. The weighted mean 206Pb/238U age of SK10-2 is 31.42±0.25 Ma(2σ ) and the RSDs of 206Pb/238U ages(2σ ) are between 2.4% and 5.7% for single measurements and less than 0.8% for weighted mean. The obtained weighted mean 206Pb/238U age is in good agreement with the age obtained by Yuan(2004). Trace element concentrations of NIST612 and NIST614 obtained under the same LA-ICP-MS operating conditions agree with the recommended values within analytical error. The results indicate that it is possible to measure U-Pb age and trace elements simultaneously by LA-ICP-MS in a small spot size of 20 μm.