The paper is devoted to the study of generalized inductive limit of C*-algebras with coherent maps being completely positive contractions of order zero: the nuclear dimension of generalized inductive limit of C*-al...The paper is devoted to the study of generalized inductive limit of C*-algebras with coherent maps being completely positive contractions of order zero: the nuclear dimension of generalized inductive limit of C*-algebras with finite nuclear dimension is finite; the generalized inductive limits of C*-algebras with the α-comparison property also have the s-comparison property.展开更多
Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advan...Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advantages and disadvantages in terms of complexity,accuracy,and specific elements of interest.In this study,the performances of inductively coupled plasma-optical emission spectrometry(ICP-OES)and total reflection X-ray fluorescence spectroscopy(TXRF)were evaluated for quality control to analyze data accuracy and precision.The statistic methods(Deming regression and significance testing)were applied for intercomparison between ICP-OES and TXRF measurements for same lowloading PM_(2.5)samples in Weizhou Island.The results from the replicate analysis of standard filters(SRM 2783)and field filters samples indicated that 10 MEs(K,Ca,V,Cr,Mn,Fe,Ni,Cu,Zn,and Pb)showed good accuracies and precision for both techniques.The higher accuracy tended to the higher precision in the MEs analysis process.In addition,the interlab comparisons illustrated that V and Mn all had good agreements between ICP-OES and TXRF.The measurements of K,Cu and Zn were more reliable by TXRF analysis for low-loading PM_(2.5).ICP-OES was more accurate for the determinations for Ca,Cr,Ni and Pb,owing to the overlapping spectral lines and low sensitivity during TXRF analysis.The measurements of Fe,influenced by low-loading PM_(2.5),were not able to determine which instrument could obtain more reliable results.These conclusions could provide reference information to choose suitable instrument for the determination of MEs in low-loading PM_(2.5)samples.展开更多
基金Supported by NSFC(Grant No.11371279)by the Fundamental Research Funds for the Central Universities
文摘The paper is devoted to the study of generalized inductive limit of C*-algebras with coherent maps being completely positive contractions of order zero: the nuclear dimension of generalized inductive limit of C*-algebras with finite nuclear dimension is finite; the generalized inductive limits of C*-algebras with the α-comparison property also have the s-comparison property.
基金supported by the National Natural Science Foundation of China(No.42075182)the Science and Technology Pre-research Project for Collaborative Prevention and Control on O3 and PM2.5 Compound Pollution(No.DQGG202026)the Three-dimensional Comprehensive Observation Research Program for O3and PM2.5Compound Pollution in Key Areas in Summer 2021(No.DQGG2021101)
文摘Over the past few decades,the metal elements(MEs)in atmospheric particles have aroused great attention.Some well-established techniques have been used to measure particlebound MEs.However,each method has its own advantages and disadvantages in terms of complexity,accuracy,and specific elements of interest.In this study,the performances of inductively coupled plasma-optical emission spectrometry(ICP-OES)and total reflection X-ray fluorescence spectroscopy(TXRF)were evaluated for quality control to analyze data accuracy and precision.The statistic methods(Deming regression and significance testing)were applied for intercomparison between ICP-OES and TXRF measurements for same lowloading PM_(2.5)samples in Weizhou Island.The results from the replicate analysis of standard filters(SRM 2783)and field filters samples indicated that 10 MEs(K,Ca,V,Cr,Mn,Fe,Ni,Cu,Zn,and Pb)showed good accuracies and precision for both techniques.The higher accuracy tended to the higher precision in the MEs analysis process.In addition,the interlab comparisons illustrated that V and Mn all had good agreements between ICP-OES and TXRF.The measurements of K,Cu and Zn were more reliable by TXRF analysis for low-loading PM_(2.5).ICP-OES was more accurate for the determinations for Ca,Cr,Ni and Pb,owing to the overlapping spectral lines and low sensitivity during TXRF analysis.The measurements of Fe,influenced by low-loading PM_(2.5),were not able to determine which instrument could obtain more reliable results.These conclusions could provide reference information to choose suitable instrument for the determination of MEs in low-loading PM_(2.5)samples.