Purpose The accelerator-driven subcritical system(ADS)is the internationally recognized key technology of nuclear waste problem treatment,of which superconducting proton linac is an important part.With the support of ...Purpose The accelerator-driven subcritical system(ADS)is the internationally recognized key technology of nuclear waste problem treatment,of which superconducting proton linac is an important part.With the support of the strategic science and technology pilot project of the Chinese Academy of Sciences,the Institute of High Energy Physics of the Chinese Academy of Sciences took the lead in the research of 325 MHz superconducting proton linac,which is called ADS Injector I.The superconducting accelerator part of ADS Injector I mainly consists of 14 spoke-type superconducting cavities withβ0.12.At the same time,the research work of various cavities with differentβvalues and different frequencies is also carried out to lay the technical and technological foundation for ADS main accelerator.The only way to determine whether the superconducting cavity can reach the design target and whether it can be installed into the cryostat is the vertical test at cryogenic.As the only way to test the microwave performance of the superconducting cavity at low temperature,the vertical test can accurately test the acceleration gradient Eacc and the corresponding quality factor Q0 of the superconducting cavity.The design and construction of the superconducting cavity vertical test facility is based on the practical needs of the pilot project and the long-term development of the superconducting accelerator.Methods This paper mainly introduces the design and construction of the cryogenic vertical test system for the superconducting cavity of ADS Injector I,including the system scheme design,process design,heat load analysis,2 K superfluid helium obtaining method,system commissioning and operation,etc.Results and Conclusion The static heat leakage at 2 K of the 2 K superfluid helium vertical test system of ADS Injector I is 1.624W,which has reached the international advanced level.The 2 K superfluid helium vertical test system of ADS Injector I after constructed not only meets the test requirements of ADS pilot project,but also conduct展开更多
he thermal performance test of the horizontal coaxial double tube hot gas duct (HGD) with an internal thermal insulation for the 10MW High Temperature Reactor Test Module (HTR10) was conducted on a Helium Test Loop(HE...he thermal performance test of the horizontal coaxial double tube hot gas duct (HGD) with an internal thermal insulation for the 10MW High Temperature Reactor Test Module (HTR10) was conducted on a Helium Test Loop(HETL). The present paper deals with the technical feature of the HETL, the test section and the thermal performance test of the HGD. The HGD test section with a triple tube structure includes an inner heater, a HGD model and a coldhot gas mixer. A counterflow of cold and hot helium gas under the pressure of about 3.0 MPa and the minimum temperature of 100℃ in the annular passage and the maximum of 950℃ in the central tube of the HGD model was formed. The HGD model was undergone 20 times of pressure cycle test under the pressure ranging from 0.1 to 3.4 MPa, 18 times of the temperature cycle test under the temperature ranging from 100 to 950℃ and high temperature (700 to 950℃) helium flow test for a period of more than 350 hours. The effective thermal conductivity (λeff) of the internal insulation of the HGD was investigated experimentally. The relationship of the effective thermal conductivity with the average tmperature of the internal insulation layer is λeff(W/m/℃)=0.3512+0.0003T(℃). The test results indicate that the HGD model has good abilities to resist heat flux from the central tube to the annular passage, temperature variations, and pressure variations.展开更多
文摘Purpose The accelerator-driven subcritical system(ADS)is the internationally recognized key technology of nuclear waste problem treatment,of which superconducting proton linac is an important part.With the support of the strategic science and technology pilot project of the Chinese Academy of Sciences,the Institute of High Energy Physics of the Chinese Academy of Sciences took the lead in the research of 325 MHz superconducting proton linac,which is called ADS Injector I.The superconducting accelerator part of ADS Injector I mainly consists of 14 spoke-type superconducting cavities withβ0.12.At the same time,the research work of various cavities with differentβvalues and different frequencies is also carried out to lay the technical and technological foundation for ADS main accelerator.The only way to determine whether the superconducting cavity can reach the design target and whether it can be installed into the cryostat is the vertical test at cryogenic.As the only way to test the microwave performance of the superconducting cavity at low temperature,the vertical test can accurately test the acceleration gradient Eacc and the corresponding quality factor Q0 of the superconducting cavity.The design and construction of the superconducting cavity vertical test facility is based on the practical needs of the pilot project and the long-term development of the superconducting accelerator.Methods This paper mainly introduces the design and construction of the cryogenic vertical test system for the superconducting cavity of ADS Injector I,including the system scheme design,process design,heat load analysis,2 K superfluid helium obtaining method,system commissioning and operation,etc.Results and Conclusion The static heat leakage at 2 K of the 2 K superfluid helium vertical test system of ADS Injector I is 1.624W,which has reached the international advanced level.The 2 K superfluid helium vertical test system of ADS Injector I after constructed not only meets the test requirements of ADS pilot project,but also conduct
文摘he thermal performance test of the horizontal coaxial double tube hot gas duct (HGD) with an internal thermal insulation for the 10MW High Temperature Reactor Test Module (HTR10) was conducted on a Helium Test Loop(HETL). The present paper deals with the technical feature of the HETL, the test section and the thermal performance test of the HGD. The HGD test section with a triple tube structure includes an inner heater, a HGD model and a coldhot gas mixer. A counterflow of cold and hot helium gas under the pressure of about 3.0 MPa and the minimum temperature of 100℃ in the annular passage and the maximum of 950℃ in the central tube of the HGD model was formed. The HGD model was undergone 20 times of pressure cycle test under the pressure ranging from 0.1 to 3.4 MPa, 18 times of the temperature cycle test under the temperature ranging from 100 to 950℃ and high temperature (700 to 950℃) helium flow test for a period of more than 350 hours. The effective thermal conductivity (λeff) of the internal insulation of the HGD was investigated experimentally. The relationship of the effective thermal conductivity with the average tmperature of the internal insulation layer is λeff(W/m/℃)=0.3512+0.0003T(℃). The test results indicate that the HGD model has good abilities to resist heat flux from the central tube to the annular passage, temperature variations, and pressure variations.