针对现有孤岛检测方法的不足之处,在分析孤岛检测基本原理的基础上提出了一种新的被动式孤岛检测方法。该方法以并网公共连接点(point of common coupling,PCC)处频率变化与负荷电压变化之比Δf/ΔVL作为检测指标,其计算值与所给门槛值...针对现有孤岛检测方法的不足之处,在分析孤岛检测基本原理的基础上提出了一种新的被动式孤岛检测方法。该方法以并网公共连接点(point of common coupling,PCC)处频率变化与负荷电压变化之比Δf/ΔVL作为检测指标,其计算值与所给门槛值相比较来判断并网系统是否发生孤岛现象。在考虑负荷突变、电网电压波动等多种扰动对孤岛检测的影响的基础上做了仿真实验。结果表明,该方法简单可行、快速可靠,且检测盲区很小。展开更多
High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC)...High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC). With the development of semiconductor devices, a voltage source converter (VSC)-based HVDC system was introduced, and has been widely applied to integrate large-scale renewables and network interconnection. However, the VSC-based HVDC system is vulnerable to DC faults and its protection becomes ever more important with the fast growth in number of installations. In this paper, detailed characteristics of DC faults in the VSC-HVDC system are presented. The DC fault current has a large peak and steady values within a few milliseconds and thus high-speed fault detection and isolation methods are required in an HVDC grid. Therefore, development of the protection scheme for a multi-terminal VSC-based HVDC system is challenging. Various methods have been developed and this paper presents a comprehensive review of the different techniques for DC fault detection, location and isolation in both CSC and VSC-based HVDC transmission systems in two-terminal and multi-terminal network configurations.展开更多
Online fault detection is one of the key technologies to improve the performance of cloud systems. The current data of cloud systems is to be monitored, collected and used to reflect their state. Its use can potential...Online fault detection is one of the key technologies to improve the performance of cloud systems. The current data of cloud systems is to be monitored, collected and used to reflect their state. Its use can potentially help cloud managers take some timely measures before fault occurrence in clouds. Because of the complex structure and dynamic change characteristics of the clouds, existing fault detection methods suffer from the problems of low efficiency and low accuracy. In order to solve them, this work proposes an online detection model based on asystematic parameter-search method called SVM-Grid, whose construction is based on a support vector machine(SVM). SVM-Grid is used to optimize parameters in SVM. Proper attributes of a cloud system's running data are selected by using Pearson correlation and principal component analysis for the model. Strategies of predicting cloud faults and updating fault sample databases are proposed to optimize the model and improve its performance.In comparison with some representative existing methods, the proposed model can achieve more efficient and accurate fault detection for cloud systems.展开更多
Considering the advantages and limitations of traditional identification method,combined with the strategy of active detection,the principle of DC grid pilot protection based on active detection is proposed to improve...Considering the advantages and limitations of traditional identification method,combined with the strategy of active detection,the principle of DC grid pilot protection based on active detection is proposed to improve the sensitivity and reliability of hybrid MMC DC grid protection,and to ensure the accurate identification of fault areas in DC grid.By using the DC fault ride-through control strategy of the hybrid sub-module MMC,the fault current at the converter station DC terminal is limited.Based on the high controllability of hybrid MMC,sinusoidal fault detection signals with the same frequency are injected into the line at each converter station.Based on model recognition,the capacitance model condition is satisfied by the detected signals at both ends during external faults whereas not satisfied during internal faults.The Spearman correlation coefficients is then introduced,and the correlation discriminant of capacitance model is constructed to realize fault area discrimination of DC grid.The simulation results show that the active detection protection scheme proposed in this paper can accurately identify the fault area of DC grid,and is not affected by fault impedance and has low sampling rate requirement.展开更多
文摘针对现有孤岛检测方法的不足之处,在分析孤岛检测基本原理的基础上提出了一种新的被动式孤岛检测方法。该方法以并网公共连接点(point of common coupling,PCC)处频率变化与负荷电压变化之比Δf/ΔVL作为检测指标,其计算值与所给门槛值相比较来判断并网系统是否发生孤岛现象。在考虑负荷突变、电网电压波动等多种扰动对孤岛检测的影响的基础上做了仿真实验。结果表明,该方法简单可行、快速可靠,且检测盲区很小。
文摘High voltage direct current (HVDC) transmission is an economical option for transmitting a large amount of power over long distances. Initially, HVDC was developed using thyristor-based current source converters (CSC). With the development of semiconductor devices, a voltage source converter (VSC)-based HVDC system was introduced, and has been widely applied to integrate large-scale renewables and network interconnection. However, the VSC-based HVDC system is vulnerable to DC faults and its protection becomes ever more important with the fast growth in number of installations. In this paper, detailed characteristics of DC faults in the VSC-HVDC system are presented. The DC fault current has a large peak and steady values within a few milliseconds and thus high-speed fault detection and isolation methods are required in an HVDC grid. Therefore, development of the protection scheme for a multi-terminal VSC-based HVDC system is challenging. Various methods have been developed and this paper presents a comprehensive review of the different techniques for DC fault detection, location and isolation in both CSC and VSC-based HVDC transmission systems in two-terminal and multi-terminal network configurations.
基金supported by the National Natural Science Foundation of China(61472005,61201252)CERNET Innovation Project(NGII20160207)
文摘Online fault detection is one of the key technologies to improve the performance of cloud systems. The current data of cloud systems is to be monitored, collected and used to reflect their state. Its use can potentially help cloud managers take some timely measures before fault occurrence in clouds. Because of the complex structure and dynamic change characteristics of the clouds, existing fault detection methods suffer from the problems of low efficiency and low accuracy. In order to solve them, this work proposes an online detection model based on asystematic parameter-search method called SVM-Grid, whose construction is based on a support vector machine(SVM). SVM-Grid is used to optimize parameters in SVM. Proper attributes of a cloud system's running data are selected by using Pearson correlation and principal component analysis for the model. Strategies of predicting cloud faults and updating fault sample databases are proposed to optimize the model and improve its performance.In comparison with some representative existing methods, the proposed model can achieve more efficient and accurate fault detection for cloud systems.
基金supported by The National Natural Science Foundation key project(U1766209).
文摘Considering the advantages and limitations of traditional identification method,combined with the strategy of active detection,the principle of DC grid pilot protection based on active detection is proposed to improve the sensitivity and reliability of hybrid MMC DC grid protection,and to ensure the accurate identification of fault areas in DC grid.By using the DC fault ride-through control strategy of the hybrid sub-module MMC,the fault current at the converter station DC terminal is limited.Based on the high controllability of hybrid MMC,sinusoidal fault detection signals with the same frequency are injected into the line at each converter station.Based on model recognition,the capacitance model condition is satisfied by the detected signals at both ends during external faults whereas not satisfied during internal faults.The Spearman correlation coefficients is then introduced,and the correlation discriminant of capacitance model is constructed to realize fault area discrimination of DC grid.The simulation results show that the active detection protection scheme proposed in this paper can accurately identify the fault area of DC grid,and is not affected by fault impedance and has low sampling rate requirement.