Scintillation detectors based on LSO, CeF and PbWO are the main candidates for measuring T- rays in a mixed γ/n pulsed radiation field with high intensity. An experiment using the Lissajous figure method to study the...Scintillation detectors based on LSO, CeF and PbWO are the main candidates for measuring T- rays in a mixed γ/n pulsed radiation field with high intensity. An experiment using the Lissajous figure method to study the high fluence rate response behavior of three kinds of commonly used scintillators is introduced in this paper. The result shows that the fluence rate linear response limit of LSO and CeF is 1.9×10^19 and 2.1 × 10^18MeV/(cm^2·s), respectively, and the PbWO scintillator still maintains linear response when the fluence rate of T-ray is up to 2.0×10^20 MeV/(cm^2·s).展开更多
Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1(GHARR-1) was measured after a beryllium reflector was...Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1(GHARR-1) was measured after a beryllium reflector was added to its shim to compensate for excess reactivity loss. The thermal, epithermal and fast neutron fluxes were determined by the method of foil activation. The experimental samples with and without a cadmium cover of 1-mm thickness were irradiated in the isotropic neutron field of the irradiation sites of Ghana Research Reactor-1 facility. The induced activities in the sample were measured by gamma ray spectrometry with a high purity germanium detector. The necessary correction for gamma attenuation, thermal neutrons and resonance neutron self-shielding effects were taken into account during the experimental analysis. By defining cadmium cutoff energy of 0.55eV, Al-0.1% Au wires of negligible thickness were irradiated at 3kW to determine the neutron fluxes of two irradiation channels, outer channel 7 and inner channel 2 whose Neutron Shaping Factor (α) were found to be (0.037 ± 0.001) and (–0.961 ± 0.034). The neutron flux ratios at the inner irradiation site 2 were found to be, (25.308 ± 3.201) for thermal to epithermal neutrons flux, (0.179 ± 0.021) for epithermal to fast neutrons flux and (4.528 ± 0.524) for thermal to fast neutrons flux, in the outer irradiation site 7, the neutron flux ratios were found to be, (40.865 ± 3.622) for thermal to epithermal neutrons flux, (0.286 ± 0.025) for epithermal to fast neutrons flux and (11.680 ± 1.030) for thermal to fast neutrons flux.展开更多
文摘Scintillation detectors based on LSO, CeF and PbWO are the main candidates for measuring T- rays in a mixed γ/n pulsed radiation field with high intensity. An experiment using the Lissajous figure method to study the high fluence rate response behavior of three kinds of commonly used scintillators is introduced in this paper. The result shows that the fluence rate linear response limit of LSO and CeF is 1.9×10^19 and 2.1 × 10^18MeV/(cm^2·s), respectively, and the PbWO scintillator still maintains linear response when the fluence rate of T-ray is up to 2.0×10^20 MeV/(cm^2·s).
文摘Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1(GHARR-1) was measured after a beryllium reflector was added to its shim to compensate for excess reactivity loss. The thermal, epithermal and fast neutron fluxes were determined by the method of foil activation. The experimental samples with and without a cadmium cover of 1-mm thickness were irradiated in the isotropic neutron field of the irradiation sites of Ghana Research Reactor-1 facility. The induced activities in the sample were measured by gamma ray spectrometry with a high purity germanium detector. The necessary correction for gamma attenuation, thermal neutrons and resonance neutron self-shielding effects were taken into account during the experimental analysis. By defining cadmium cutoff energy of 0.55eV, Al-0.1% Au wires of negligible thickness were irradiated at 3kW to determine the neutron fluxes of two irradiation channels, outer channel 7 and inner channel 2 whose Neutron Shaping Factor (α) were found to be (0.037 ± 0.001) and (–0.961 ± 0.034). The neutron flux ratios at the inner irradiation site 2 were found to be, (25.308 ± 3.201) for thermal to epithermal neutrons flux, (0.179 ± 0.021) for epithermal to fast neutrons flux and (4.528 ± 0.524) for thermal to fast neutrons flux, in the outer irradiation site 7, the neutron flux ratios were found to be, (40.865 ± 3.622) for thermal to epithermal neutrons flux, (0.286 ± 0.025) for epithermal to fast neutrons flux and (11.680 ± 1.030) for thermal to fast neutrons flux.