The failure depth of the coal seam floor is one important consideration that must be kept in mind when mining is carried out above a confined aquifer.Determining the floor failure depth is the essential precondition f...The failure depth of the coal seam floor is one important consideration that must be kept in mind when mining is carried out above a confined aquifer.Determining the floor failure depth is the essential precondition for predicting the water-resisting ability of the floor.We have used a high-precision microseismic monitoring technique to overcome the limited amount of data available from field measurements. The failure depth of a coal seam floor,especially an inclined coal seam floor,may be more accurately estimated by monitoring the continuous,dynamic failure of the floor.The monitoring results indicate the failure depth of the coal seam floor near the workface conveyance roadway(the lower crossheading) is deeper and that the failure range is wider here compared to the coal seam floor near the return airway(the upper crossheading).The results of micro-seismic monitoring show that the dangerous area for water-inrush from the coal seam floor may be identified.This provides an important field measurement that helps ensure safe and highly efficient mining of the inclined coal seam above the confined aquifer at the Taoyuan Coal Mine.展开更多
In industry,multiple hearth furnaces are used for the thermal treatment of particulate material.The current contribution concentrates on the experimental analysis of particle mechanics for a batch-operated single floo...In industry,multiple hearth furnaces are used for the thermal treatment of particulate material.The current contribution concentrates on the experimental analysis of particle mechanics for a batch-operated single floor of a multiple hearth furnace.The particles are agitated on the circular floor by a single,rotating rabble arm equipped with three flat rabble blades of 10 mm thickness.The blade angle,defined as the angle,which the blade is inclined against the tangential direction,is varied from 0°to 90°.A single layer of spherical polyoxymethylene(POM)particles with three different diameters(5,10 and 20 mm)is placed on the floor.To analyze the results,two parameters have been extracted from image analysis when the bed of particles is agitated,first,the area not covered by particles and second,the frequency distribution of the mean distance among the particles.The particle free surface area increases with the inclination of the blades.The evolution of the particle free surface area differs for the different particle diameters.In general,the maximum particle free area for all blade angles is the largest for the 5 mm particles followed by the 20 mm particles.For the 10 mm particles,the particle free surface area starts for a blade angle of 0°at larger values than for the 20 mm particles but the values fall below the values for the 20 mm particles for larger blade angles.The reason for this behavior is discussed in detail.The mean distance among the particles is a parameter characterizing the length scales dominating the effects on the floor.The frequency distribution of the mean distance among particles provides infor-mation about the morphology of the particle bulk,for example,whether the free surface area is inter-spersed with particles.展开更多
基金supported by the National Basic Research Program ofChina(No.2010CB202210)the National Natural Science Foundation of China(No.50874103)+1 种基金the Natural Science Foundation of Jiangsu Province(No.KB2008135)as well as by the Qinglan Project of Jiangsu Province
文摘The failure depth of the coal seam floor is one important consideration that must be kept in mind when mining is carried out above a confined aquifer.Determining the floor failure depth is the essential precondition for predicting the water-resisting ability of the floor.We have used a high-precision microseismic monitoring technique to overcome the limited amount of data available from field measurements. The failure depth of a coal seam floor,especially an inclined coal seam floor,may be more accurately estimated by monitoring the continuous,dynamic failure of the floor.The monitoring results indicate the failure depth of the coal seam floor near the workface conveyance roadway(the lower crossheading) is deeper and that the failure range is wider here compared to the coal seam floor near the return airway(the upper crossheading).The results of micro-seismic monitoring show that the dangerous area for water-inrush from the coal seam floor may be identified.This provides an important field measurement that helps ensure safe and highly efficient mining of the inclined coal seam above the confined aquifer at the Taoyuan Coal Mine.
基金funded by the Deutsche Forschungsgemeinschaft(DFG,German Research Foundation)-Project-ID 422037413-TRR 287.
文摘In industry,multiple hearth furnaces are used for the thermal treatment of particulate material.The current contribution concentrates on the experimental analysis of particle mechanics for a batch-operated single floor of a multiple hearth furnace.The particles are agitated on the circular floor by a single,rotating rabble arm equipped with three flat rabble blades of 10 mm thickness.The blade angle,defined as the angle,which the blade is inclined against the tangential direction,is varied from 0°to 90°.A single layer of spherical polyoxymethylene(POM)particles with three different diameters(5,10 and 20 mm)is placed on the floor.To analyze the results,two parameters have been extracted from image analysis when the bed of particles is agitated,first,the area not covered by particles and second,the frequency distribution of the mean distance among the particles.The particle free surface area increases with the inclination of the blades.The evolution of the particle free surface area differs for the different particle diameters.In general,the maximum particle free area for all blade angles is the largest for the 5 mm particles followed by the 20 mm particles.For the 10 mm particles,the particle free surface area starts for a blade angle of 0°at larger values than for the 20 mm particles but the values fall below the values for the 20 mm particles for larger blade angles.The reason for this behavior is discussed in detail.The mean distance among the particles is a parameter characterizing the length scales dominating the effects on the floor.The frequency distribution of the mean distance among particles provides infor-mation about the morphology of the particle bulk,for example,whether the free surface area is inter-spersed with particles.