For reducing both extreme ultraviolet attosecond pulses energy loss in the focusing reflection process and measurement error caused by pulse focusing aberration, as well as improving the operability of pulse spectrosc...For reducing both extreme ultraviolet attosecond pulses energy loss in the focusing reflection process and measurement error caused by pulse focusing aberration, as well as improving the operability of pulse spectroscopy monitoring, a combined focusing and flat-field spectrometer analysis system for attosecond pulse is proposed and designed through step-by-step performance optimization. The focusing and spectrum-analyzing components are gold- coated grazing incidence to roidal mirror and grazing incidence concave focusing grating, respectively. The characteristic parameters of the system are given in details. The system proposed can find application in research platform of attosecond spectroscopy using high energy short attosecond pulse as basic probe tool.展开更多
We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of ...We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.展开更多
A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate co...A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.展开更多
文摘For reducing both extreme ultraviolet attosecond pulses energy loss in the focusing reflection process and measurement error caused by pulse focusing aberration, as well as improving the operability of pulse spectroscopy monitoring, a combined focusing and flat-field spectrometer analysis system for attosecond pulse is proposed and designed through step-by-step performance optimization. The focusing and spectrum-analyzing components are gold- coated grazing incidence to roidal mirror and grazing incidence concave focusing grating, respectively. The characteristic parameters of the system are given in details. The system proposed can find application in research platform of attosecond spectroscopy using high energy short attosecond pulse as basic probe tool.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11405158 and 11775203)the Presidential Foundation of China Academy of Engineering Physics(Grant No.YZJJLX 2016007)
文摘We develop a rapid and convenient experimental method of absolutely calibrating the transmission of an x-ray flatresponse filter. The calibration experiment is performed on a small laser-target facility, and a set of high resolution holographic flat-field grating spectrometers is used as a discrimination system of the laser-produced x-ray source. Given that the holographic flat-field grating has a relatively large width, the grating is divided into two regions for use in that direction,where one region has the filter added and the other region does not. The filter transmission is determined by dividing the x-ray signal counts detected when the filter is in the line of sight by those detected when the filter is out of the line of sight.We find that the calibration results of this experiment agree with the calibration results using a synchrotron radiation source,as well as simulation results. Our method is not only highly reliable but also rapid and convenient.
基金supported by the National Natural Science Foundation of China(Grant Nos.11221002,11274152,and 11074297)
文摘A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.