Production and test of sPHENIX W/SciFiber electromagnetic calorimeter blocks in China
1
作者 Xiao‑Zhou Yu Xi‑Yang Wang +11 位作者 Wei‑Hu Ma Shi‑Hong Fu Peng‑Fei Sun Jin‑Xing Song Wan‑Bing He Yang Shen Long Ma Jin‑Hui Chen Huan‑Zhong Huang Si‑Guang Wang Jing Zhou Xiao‑Mei Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期167-176,共10页
The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quar... The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quark–Gluon plasma with hard probes of jets,open heavy flavor particles,andγproduction.The EMCal detector,which covers the pseudo-rapidity region of|η|≤1.1,is an essential subsystem of sPHENIX.In this study,we focused on producing and testing EMCal blocks covering a pseudo-rapidity of|η|∈[0.8,1.1].These,in conjunction with the central pseudo-rapidity EMCal blocks,significantly enhance the sPHENIX physics capability of the jet andγparticle measurements.In this paper,the detector module production and testing of sPHENIX W-powder/scintillating fiber(W/ScFi)electromagnetic calorimeter blocks are presented.The selection of the tungsten powder,mold fabrication,QA procedures,and cosmic ray test results are discussed. 展开更多
关键词 sPHENIX Tungsten/scintillating fiber electromagnetic calorimeter Cosmic ray test
下载PDF
Equalization for the low-response cells of the AMS-02 electromagnetic calorimeter
2
作者 Jia-Yu Hu Ze-Tong Sun +9 位作者 Zu-Hao Li Zhi-Cheng Tang Cheng Zhang Feng-Ze Zhang Shang-Lin Li Mei-Jun Liang Hao-Tian Yang Yu-Hang You Meng Wang He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2023年第3期350-354,共5页
Purpose Performing precision equalization on the low-response detection units of electromagnetic calorimeter(ECAL),it is essential for precision energy measurements of Alpha Magnetic Spectrometer(AMS-02).Methods Cosmi... Purpose Performing precision equalization on the low-response detection units of electromagnetic calorimeter(ECAL),it is essential for precision energy measurements of Alpha Magnetic Spectrometer(AMS-02).Methods Cosmic helium nuclei are used instead of protons to perform the equalization.During the equalization,temperature effects are analyzed and corrected to improve the accuracy.Results The results of helium equalization are consistent with proton equalization,and the precision of helium equalization is about 1.5%.Conclusions The precision of helium equalization is better than that of proton equalization,which provides a reliable alternative to ECAL on-orbit equalization. 展开更多
关键词 electromagnetic calorimeter EQUALIZATION Helium MIP Temperature effect
原文传递
Geant4 application for efficiency simulation of PbF2 based calorimeters
3
作者 A.A.Savchenko A.A.Tishchenko 《Radiation Detection Technology and Methods》 CSCD 2023年第3期435-446,共12页
Purpose This study aims to create a new tool for fast computer simulations allowing one to design advanced electromagnetic calorimeters with the required properties.The application must calculate the calorimeter effic... Purpose This study aims to create a new tool for fast computer simulations allowing one to design advanced electromagnetic calorimeters with the required properties.The application must calculate the calorimeter efficiency and measure the particles'energies,momenta and interaction time to detect the particles.This application should become the basis for a new technology of positron emission tomography.Methods To solve the problem,a new C++application based on Geant4 simulation toolkit has been developed.To monitor the response of calorimeters to different types of primary particles,we used different auxiliary Geant4 classes.In addition,we compare the simulation results for the detectors of three different setups,taking into account the detection of both electrons and gamma-quanta,and analyze their efficiency.To evaluate the capability of calorimeters to work under radiation load,we use an experimentally measured transmission function of radiation-damaged PbF_(2).Results Three calorimeter setups exploiting PbF_(2)were simulated with a new C++application based on Geant4.We showed that such type of calorimeter has an energy resolution of 4.1%√E^(e+)[GeV]and good linearity of response for GeV positrons measurements.The efficiency of such structures is found to be approximately 20%for gamma photons’detection.The multilayered structure based on gamma-quanta detection has been proven to be more efficient.It was shown that for the total ionizing dose of 30 krad the Cherenkov light yield decreases by up to two times for 14 cm long PbF_(2)crystals,while for the shorter ones(2.5 and 1.5 cm)this effect is almost negligible.Conclusions We present a new user application in Geant4 for fast simulation of complex structures designed for detection of different high-energy neutral and charged particles.Simulation of calorimeter interaction with 10^(3) of 3 GeV positrons takes 20 min on usual laptop,while for 105511 keV gamma photons it takes 1 min on average.This application allows one to evaluate the efficiency of electromagne 展开更多
关键词 GEANT4 Cherenkov radiation Positron emission tomography electromagnetic calorimeter PbF_(2)
原文传递
Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter 被引量:1
4
作者 李祖豪 王玲玉 +3 位作者 许伟伟 陈国明 吕雨生 陈和生 《Chinese Physics C》 SCIE CAS CSCD 2013年第2期64-67,共4页
The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposit... The position effect of the photoelectron multiplier tube (PMT) of the electromagnetic calorimeter (ECAL) of Alpha Magnetic Spectrometer-02 (AMS-02) has been studied with beam-test data. The reconstructed deposited energy in a layer versus incidence position in the cell can be described by Gaussian distribution, maximum and minimum value can be obtained when the particle passes across the center and the edge of a cell respectively. The distribution can be used to correct the effect of incidence position on energy reconstruction. Much better energy resolution was acquired be got with the correction, for 100 GeV electrons, energy resolution improved from 3% to 2%. 展开更多
关键词 electromagnetic calorimeter photo multiplier tube position effect energy resolution
原文传递
Angular reconstruction of a lead scintillating-fiber sandwiched electromagnetic calorimeter 被引量:1
5
作者 李祖豪 许伟伟 +7 位作者 王玲玉 张诚 唐志成 严琪 杨民 吕雨生 陈国明 陈和生 《Chinese Physics C》 SCIE CAS CSCD 2014年第5期76-81,共6页
The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was... The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters. 展开更多
关键词 electromagnetic calorimeter angular resolution lateral fit Neighbor Cell Deposited Energy Ratio
原文传递
基于波形采样的CEPC电磁量能器读出单元测试系统 被引量:2
6
作者 李明慧 牛萍娟 +5 位作者 董明义 赵航 胡鹏 于丽媛 胡涛 王志刚 《核技术》 CAS CSCD 北大核心 2018年第1期39-44,共6页
随着环形正负电子对撞机(Circular Electron Positron Collider,CEPC)方案的提出,由硅光电倍增管(Silicon Photomultiplier,SiPM)和塑料闪烁体组成的读出单元作为电磁量能器的预研方案之一,逐渐成为研究热点。在探测器预研阶段需要对读... 随着环形正负电子对撞机(Circular Electron Positron Collider,CEPC)方案的提出,由硅光电倍增管(Silicon Photomultiplier,SiPM)和塑料闪烁体组成的读出单元作为电磁量能器的预研方案之一,逐渐成为研究热点。在探测器预研阶段需要对读出单元性能进行充分研究,因此我们设计了一套自动化测试系统用于对读出单元进行测试、分析并改善其性能。利用DT5751波形采样插件、SiPM驱动电路板、步进电机、低压电源、继电器等完成硬件搭建,以LabVIEW为开发平台完成了软件的串行协议接口之间的通信,实现了读出单元的自动化测试,编写了相应的数据处理程序。在此基础上进行了SiPM刻度、闪烁体发光均匀性以及反射材料对光输出影响的研究。测试结果表明,ESR反射膜包裹的塑闪条具有最高的光输出,塑闪条耦合10μm像素SiPM的光输出为耦合25μm像素SiPM的三分之一。 展开更多
关键词 硅光电倍增管 塑料闪烁体 电磁量能器 环形正负电子对撞机
原文传递
Absolute photon energy calibration for the BESⅢ EMC
7
作者 边渐鸣 何康林 +11 位作者 李卫国 胡涛 傅成栋 黄彬 刘颖 吕绮雯 宁飞鹏 宋文博 孙胜森 徐敏 言杰 严亮 《Chinese Physics C》 SCIE CAS CSCD 2010年第1期72-77,共6页
The absolute energy calibration with photons from π0's for the BESⅢ EMC is discussed. Using 3 million hadronic events, the preliminary results are presented. Precision of about 1% in the photon energy measurement i... The absolute energy calibration with photons from π0's for the BESⅢ EMC is discussed. Using 3 million hadronic events, the preliminary results are presented. Precision of about 1% in the photon energy measurement is obtained from crossing check using photons in ψ(2S)→γχc1,2(1P). 展开更多
关键词 electromagnetic calorimeter absolute energy calibration π0 decay.
原文传递
S tudy on Doped Fluoride Glasses for Scintillation Applications
8
作者 Shaukat S +3 位作者 F. Farooq R 《Journal of Shanghai University(English Edition)》 CAS 2002年第4期303-306,共4页
This paper studies the properties of fluoride glasses for use in particle calorimeters or in optical fibers. The effects of major and minor impurities in manufacturing process and ultimately on the glass properties ha... This paper studies the properties of fluoride glasses for use in particle calorimeters or in optical fibers. The effects of major and minor impurities in manufacturing process and ultimately on the glass properties have been investigated. Glasses in a range of compositions have been made and tested in the form of small samples as well as larger blocks of size 2×3×14 cm 3. Results of measurements on these materials, using a high energy particle beam, are presented. 展开更多
关键词 heavy metal fluoride glasses scintillation electromagnetic calorimeter.
下载PDF
Cosmic-ray helium nuclei measurement with the calorimeter of the Alpha Magnetic Spectrometer
9
作者 Feng-ze Zhang Zhi-Cheng Tang +6 位作者 Zu-Hao Li Cheng Zhang Ze-Tong Sun Jia-Yu Hu Shang-Lin Li Guo-Ming Chen He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2022年第3期427-432,共6页
Purpose The distributions of energy responses of helium measured by the electromagnetic calorimeter(ECAL)of Alpha Magnetic Spectrometer(AMS-02)in Monte-Carlo do not agree with those in real data,thus using energy resp... Purpose The distributions of energy responses of helium measured by the electromagnetic calorimeter(ECAL)of Alpha Magnetic Spectrometer(AMS-02)in Monte-Carlo do not agree with those in real data,thus using energy response matrix obtained from Monte-Carlo to measure the cosmic ray helium spectrum is not correct.Therefore,the spectrum measured with ECAL based on raw Monte-Carlo would be different from the real one.The purpose is to correct the response matrix to measure helium spectrum with ECAL.Methods The energy measured by ECAL of AMS-02 provides in-flight correction for the energy response matrix in Monte-Carlo.Results The spectrum based on corrected response matrix is consistent with the AMS collaboration published result.Conclusions It is feasible to measure helium spectrum with ECAL with corrected energy response matrix. 展开更多
关键词 Cosmic rays Helium spectrum electromagnetic calorimeter Monte Carlo simulation Fig.1 a The structure of ECAL b The indication of PMTs in one superlayer
原文传递
Improvements on the particle identification with dead cell and side leakage corrections for the electromagnetic calorimeter of the Alpha Magnetic Spectrometer 被引量:1
10
作者 Shao-Wen Zhang Zu-Hao Li +7 位作者 Xue-Qiang Wang Cheng Zhang Zhi-Cheng Tang Suzan Basegmez du Pree Fei Zhao Ze-Tong Sun Guo-Ming Chen He-Sheng Chen 《Radiation Detection Technology and Methods》 2018年第2期14-18,共5页
Background The electromagnetic calorimeter(ECAL)of the Alpha Magnetic Spectrometer(AMS-02)measures the energy of electrons/positrons and separates them from protons.Currently,there are five dead cells in the ECAL whic... Background The electromagnetic calorimeter(ECAL)of the Alpha Magnetic Spectrometer(AMS-02)measures the energy of electrons/positrons and separates them from protons.Currently,there are five dead cells in the ECAL which affect the reconstructed energy of particles.The particle identification power of the ECAL decreases when particles pass through these dead cells or close to the ECAL border.Purpose To improve the ECAL particle identification for particles pass through these dead cells or close to the ECAL border.Methods An improved ECAL particle identification estimator using the electromagnetic shower shape is developed with dead cell and side leakage corrections.Results For events passing through dead cells,with this new estimator,the proton rejection power is improved by a factor of 2.2 and positron purity is improved from 31 to 50%in the energy range of 500–800 GeV.Conclusion The new estimator works well for event passing through dead cells or close to the ECAL border. 展开更多
关键词 Electron/proton separation electromagnetic calorimeter(ECAL) Boosted Decision Trees(BDT) Dead cell correction Side leakage correction
原文传递
shashlyk电磁量能器研制 被引量:1
11
作者 王溪葳 申忱迪 +2 位作者 王义 韩冬 李元景 《核电子学与探测技术》 CAS 北大核心 2016年第11期1156-1159,共4页
介绍了一种取样型电磁量能器。该电磁量能器采用了先进的shashlyk型设计,通过前期模拟能量沉积,设计并制作加压工装,最后进行了压力温度稳定性测试。模拟及测试结果表明:3 Ge V电子在量能器中能量几乎达到完全沉积,以及在-10-30℃条件... 介绍了一种取样型电磁量能器。该电磁量能器采用了先进的shashlyk型设计,通过前期模拟能量沉积,设计并制作加压工装,最后进行了压力温度稳定性测试。模拟及测试结果表明:3 Ge V电子在量能器中能量几乎达到完全沉积,以及在-10-30℃条件下仪器的温度变化牢固性,很好地证明了该设计的正确性。 展开更多
关键词 电磁量能器 模拟 闪烁体 波长转换光纤
下载PDF
钨酸铅晶体抗辐射性能的测试 被引量:1
12
作者 邵明 陈宏芳 +3 位作者 李澄 陈辉 许咨宗 汪兆民 《高能物理与核物理》 EI CSCD 北大核心 2000年第6期554-559,共6页
大型强子对撞机 (LHC)运行时具有很高的辐射背景 ,为达到所要求的电磁量能器的测量精度对研制中的钨酸铅晶体的抗辐照性能提出了很高的要求 .本文主要介绍了用6 0 Co的γ射线 ,在相应的辐照剂量率辐照下 ,对几种全尺寸( 2 3cm长 )钨酸... 大型强子对撞机 (LHC)运行时具有很高的辐射背景 ,为达到所要求的电磁量能器的测量精度对研制中的钨酸铅晶体的抗辐照性能提出了很高的要求 .本文主要介绍了用6 0 Co的γ射线 ,在相应的辐照剂量率辐照下 ,对几种全尺寸( 2 3cm长 )钨酸铅晶体抗辐照性能的评估和测量方法 .研究了晶体在侧面辐照条件下对光产额及纵向发光均匀性的影响 。 展开更多
关键词 钨酸铅晶体 电磁量能器 抗辐射能力 对撞机 LHC
原文传递
应用于NICA-MPD的Shashlik取样型电磁量能器性能模拟 被引量:1
13
作者 曾德凯 彭肖宇 +6 位作者 魏鑫 程凯 季选韬 朱坤 屈国普 胡创业 王晓冬 《核技术》 CAS CSCD 北大核心 2021年第8期16-26,共11页
俄罗斯重离子超导同步加速器的多功能探测器(Nuclotron-based IonColliderFacility'sMultiPurpose Detector,NICA-MPD)采用Shashlik取样型电磁量能器(ElectromagneticCalorimeter,ECAL),设计为由32个扇区组成的圆柱形桶共包含有4300... 俄罗斯重离子超导同步加速器的多功能探测器(Nuclotron-based IonColliderFacility'sMultiPurpose Detector,NICA-MPD)采用Shashlik取样型电磁量能器(ElectromagneticCalorimeter,ECAL),设计为由32个扇区组成的圆柱形桶共包含有43008个构层(tower),每个tower由220层吸收体铅片与塑料闪烁体片交替组成。本文对影响其性能的多个参数进行了模拟研究,利用GEANT4软件模拟了影响电磁量能器的能量沉积、能量泄漏、能量分辨率等多种参数。模拟结果表明:不同物质作为吸收体时,高原子序数(Z)物质有利于能量沉积,并且能量主要沉积在吸收体中,占比为65%左右;在兼顾能量分辨率与位置分辨率需求后,电磁量能器的每个tower横截面边长设置为4 cm为最优;由于单个tower中横向泄漏大于30%,是能量泄漏的主要原因,因此在实验中可考虑在侧面加涂具有反射作用的涂料层;对于3×3 tower多个组合情况,当吸收体与闪烁体总厚度为1.8 mm时,且吸收体铅为0.3mm时,能量分辨率能达到满足实验需求的5%@3 GeV;在不同入射能量下,量能器的能量沉积具有良好的线性关系,多个tower组合能提高能量分辨率与能量沉积,且能量越高时,能量分辨率越好。另外通过模拟计算表明,当辐射长度达到13X_(0)时,能量沉积达到最大值,同时得到最佳的能量分辨率,因此NICA-MPD的电磁量能器设计长度约为415 mm,等效于电子经过约12.8个辐射长度。Tower侧面增加反射层能够使移波光纤中的光子数提高10%~19%,光纤端面增加反射层能使到达探测器的光子数提高约50%,验证了增加反射层的重要性和必要性。 展开更多
关键词 电磁量能器 GEAN4模拟 能量沉积 能量分辨率 能量泄漏
原文传递
Shashlyk电磁量能器反光层性能研究
14
作者 李昂 冯思远 +1 位作者 张忠泉 焦健斌 《核电子学与探测技术》 CAS 北大核心 2016年第8期873-876,共4页
Shashlyk电磁量能器采用薄片型闪烁体,包裹闪烁体的反光层材料对其光学性能有重要影响。本工作搭建了一套宇宙线μ子测试系统,测量不同反光层材料对闪烁体光学性能的影响。测量结果表明,反光层材料的反射率是影响闪烁体光收集效率的主... Shashlyk电磁量能器采用薄片型闪烁体,包裹闪烁体的反光层材料对其光学性能有重要影响。本工作搭建了一套宇宙线μ子测试系统,测量不同反光层材料对闪烁体光学性能的影响。测量结果表明,反光层材料的反射率是影响闪烁体光收集效率的主要因素。 展开更多
关键词 Shashlyk 电磁量能器 闪烁体 反光层 宇宙线斗子
下载PDF
Improvement in the 3D shower shapes description in the Monte Carlo simulation for a lead-scintillating fiber electromagnetic calorimeter
15
作者 Xue-Qiang Wang Zu-Hao Li +7 位作者 Zhi-Cheng Tang Cheng Zhang Fei Zhao Ze-Tong Sun Feng-Ze Zhang Jia-Yu Hu Guo-Ming Chen He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2019年第3期136-140,共5页
Background The lead-scintillating fiber electromagnetic calorimeter(ECAL)of the Alpha Magnetic Spectrometer measures the energy of positrons/electrons and separates them from hadrons.The electromagnetic shower shapes ... Background The lead-scintillating fiber electromagnetic calorimeter(ECAL)of the Alpha Magnetic Spectrometer measures the energy of positrons/electrons and separates them from hadrons.The electromagnetic shower shapes from Monte Carlo(MC)simulation and data show disagreement.Purpose Tuning the MC to make the shower shapes from MC and data agree with each other.Methods The tuning is based on a 3D electromagnetic shower model.Results After tuning,the electromagnetic shower shapes are well described by MC up to TeV.As a result,the output of ECAL electron/proton separation estimator,ECAL BDT,shows thatMCand data are in good agreement.The proton rejection power of the ECAL BDT trained with MC electron samples is improved by a factor of 5 at∼800 GeV compared to the one trained with data. 展开更多
关键词 electromagnetic calorimeter Monte Carlo simulation 3D shower shape Electron proton separation estimator
原文传递
Improvement of cosmic-ray protonmeasurement with the electromagnetic calorimeter of the Alpha Magnetic Spectrometer
16
作者 Fei Zhao Zhi-Cheng Tang +6 位作者 Zu-Hao Li Cheng Zhang Ze-Tong Sun Feng-Ze Zhang Jia-Yu Hu Guo-Ming Chen He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2021年第1期90-94,共5页
Purpose The energy response of protons measured by electromagnetic calorimeter(ECAL)of Alpha Magnetic Spectrometer(AMS-02)shows disagreement between Monte Carlo(MC)simulation and data.Therefore,using the response matr... Purpose The energy response of protons measured by electromagnetic calorimeter(ECAL)of Alpha Magnetic Spectrometer(AMS-02)shows disagreement between Monte Carlo(MC)simulation and data.Therefore,using the response matrix from MC to apply the energy unfolding,which is crucial for cosmic-ray proton spectrum measurement,is unreliable.As a result,cosmic-ray proton spectrum measured by ECAL based on raw MC would be different from the published results(based on the momentum measurement)by AMS-02.The purpose is tuning the response matrix to agree with data.Methods The independent energy measurement by AMS-02 magnetic spectrometer provides in-flight calibration for ECAL.The distributions of proton energy measured by ECAL in MC are corrected after the calibration.Results The proton spectrum based on the tuned response matrix is consistent with the published one.Conclusions The matrix tuning is effective for the energy unfolding for cosmic-ray proton spectrum measurement. 展开更多
关键词 Cosmic rays Proton spectrum electromagnetic calorimeter Monte Carlo simulation
原文传递
北京谱仪Ⅲ电磁量能器触发系统的模拟研究
17
作者 王大勇 刘振安 +4 位作者 金大鹏 徐昊 赵棣新 过雅南 李卫国 《高能物理与核物理》 CSCD 北大核心 2005年第2期168-174,共7页
利用北京谱仪Ⅲ探测器模拟和触发系统模拟程序,研究了北京谱仪Ⅲ电磁量能器的触发方案.根据物理目标设计了中性事例触发,巴巴事例判选和带电事例触发的方案,优化了各触发条件的参数,并仔细研究了对本底的排斥能力.研究了一批典型的物理... 利用北京谱仪Ⅲ探测器模拟和触发系统模拟程序,研究了北京谱仪Ⅲ电磁量能器的触发方案.根据物理目标设计了中性事例触发,巴巴事例判选和带电事例触发的方案,优化了各触发条件的参数,并仔细研究了对本底的排斥能力.研究了一批典型的物理道,给出了它们的触发效率,同时给出了预期的本底触发事例率. 展开更多
关键词 北京谱仪Ⅲ 电磁量能器 触发模拟 正负电子对撞机
原文传递
BESⅢ电磁量能器位置重建及其修正
18
作者 李宁 刘春秀 +3 位作者 董燎原 李宁博 阮向东 何苗 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第4期499-504,共6页
介绍了BESIII电磁量能器(EMC)位置重建及其修正的研究工作。利用蒙特卡罗模拟(MC)单电子和单光子分别对θ向和向进行修正,修正参数考虑了能量和位置依赖;对于真实数据,θ向位置修正量与MC修正量有微小差异,在MC修正的基础上,利用Bhabh... 介绍了BESIII电磁量能器(EMC)位置重建及其修正的研究工作。利用蒙特卡罗模拟(MC)单电子和单光子分别对θ向和向进行修正,修正参数考虑了能量和位置依赖;对于真实数据,θ向位置修正量与MC修正量有微小差异,在MC修正的基础上,利用Bhabha数据确定真实数据的二次修正参数。利用Bhabha事例和双光子事例检验EMC位置重建性能,MC模拟与真实数据位置分辨基本一致,动量为1 GeV的电子在θ向位置分辨达到5.6 mm,达到了BESIII EMC的设计指标。 展开更多
关键词 电磁量能器 位置重建 位置修正
下载PDF
On-orbit equalization of the electromagnetic calorimeter of the Alpha Magnetic Spectrometer
19
作者 Ze-Tong Sun Jia-Yu Hu +7 位作者 Zhi-Cheng Tang Cheng Zhang Feng-Ze Zhang Shang-Lin Li Mei-Jun Liang Zu-Hao Li Guo-Ming Chen He-Sheng Chen 《Radiation Detection Technology and Methods》 CSCD 2021年第3期430-433,共4页
Purpose The Alpha Magnetic Spectrometer(AMS-02)will continuously collect data for the lifetime of the International Space Station(ISS).On-orbit equalization must be performed to ensure the accuracy of the AMS energy m... Purpose The Alpha Magnetic Spectrometer(AMS-02)will continuously collect data for the lifetime of the International Space Station(ISS).On-orbit equalization must be performed to ensure the accuracy of the AMS energy measurement(~1%)by the electromagnetic calorimeter(ECAL).Methods The equalization is performed using the most probable value(MPV)of the cosmic-ray proton minimum ionizing particle(MIP).Kalman filter technique is used to improve the precision.Results The precision of the equalization with proton MIP is(7.206±0.003)%and improved to(2.388±0.002)%after the Kalman filter.From the toy Monte Carlo(MC)simulation,the error of the energy reconstruction is about 1.4%and 0.5%due to the 7.2%and 2.4%equalization accuracy,respectively.Conclusion About 1.4%error due to~7%equalization precision does not match the AMS requirement.With the improvement from the Kalman filter,the energy reconstruction error from the equalization is reduced to 0.5%,which can fulfill the AMS requirement. 展开更多
关键词 EQUALIZATION electromagnetic calorimeter Kalman filter Proton MIP Energy resolution
原文传递
BESⅢ电磁量能器光子绝对能量刻度的研究
20
作者 穆春光 刘春秀 +1 位作者 马凤才 边渐鸣 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第4期437-442,469,共7页
对BESIII电磁量能器(EMC)光子绝对能量刻度进行了的研究。利用蒙特卡罗模拟(MC)单光子事例对MC数据进行刻度;对于真实数据,在MC刻度的基础上,利用ψ'衰变到π0的单举过程进行二次刻度。同时对飞行时间计数器(TOF)能量重建与EMC匹配... 对BESIII电磁量能器(EMC)光子绝对能量刻度进行了的研究。利用蒙特卡罗模拟(MC)单光子事例对MC数据进行刻度;对于真实数据,在MC刻度的基础上,利用ψ'衰变到π0的单举过程进行二次刻度。同时对飞行时间计数器(TOF)能量重建与EMC匹配重建光子能量的情况,也给出了很好的刻度。利用ψ'→γXc1.2过程对刻度结果进行检验,结果表明光子能量测量的误差小于0.5﹪。 展开更多
关键词 电磁量能器 刻度因子 绝对能量刻度
下载PDF