At present,electrode line impedance supervision(ELIS)based protection is widely used to detect faults on grounding electrode lines,which are indispensable elements of high-voltage direct current(HVDC)systems.The exist...At present,electrode line impedance supervision(ELIS)based protection is widely used to detect faults on grounding electrode lines,which are indispensable elements of high-voltage direct current(HVDC)systems.The existing theoretical analysis of measured impedance is based on lumped line model and the threshold value is generally set according to engineering experience,which have caused the dead zone problem and even accidents.Therefore,a study on measured impedance of ELIS-based protection and its threshold value selection method is carried out to solve this problem.In this study,the expressions of measured impedance under normal operation and fault conditions are deduced based on rigorous and accurate line model.Based on the expressions,the characteristics of the measured impedance are calculated and analyzed.With the characteristics of the measured impedance,the applicability of the protection with the traditional threshold value is further discussed and the distribution of the dead zone can be located.Then,the method to calculate the threshold value of ELIS-based protection is proposed.With a proper threshold value selected by the proposed method,the dead zone of ELIS-based protection is effectively eliminated,and the protection can identify all types of faults even with large transition resistances.Case studies on PSCAD/EMTDC have been conducted to verify the conclusion.展开更多
Cochlear duct length (CDL) measurement or estimation is a hot topic for various research groups in the cochlear implant (CI) field as of today.Getting the CDL along the outer wall (LW) and organ of corti (OC) is possi...Cochlear duct length (CDL) measurement or estimation is a hot topic for various research groups in the cochlear implant (CI) field as of today.Getting the CDL along the outer wall (LW) and organ of corti (OC) is possible but considering the clinical application especially in the selection of the electrode array length and applying Greenwood's frequency function,we need to have a clear understanding on the CDL in general and as well on the Greenwood's frequency function.It is very clear from the histology images of the cochlea with straight electrode inside,that the electrode locates itself right under the basilar membrane.Also the Greenwood's frequency function involves a variable that corresponds to the CDL at the basilar membrane/organ of corti level This brings us to conclude that the CDL at the OC is relevant for the selection of electrode array length and in applying Greenwood's frequency function.The ratio between CDL (LW) and CDL (OC) is 0.9 which is a very important number that needs to be remembered when converting CDL (LW) to CDL (OC).展开更多
基金supported by the National Natural Science Foundation of China for Distinguished Young Scholars(No.52025071)the Joint Funds of the National Natural Science Foundation of China(No.U1866205)。
文摘At present,electrode line impedance supervision(ELIS)based protection is widely used to detect faults on grounding electrode lines,which are indispensable elements of high-voltage direct current(HVDC)systems.The existing theoretical analysis of measured impedance is based on lumped line model and the threshold value is generally set according to engineering experience,which have caused the dead zone problem and even accidents.Therefore,a study on measured impedance of ELIS-based protection and its threshold value selection method is carried out to solve this problem.In this study,the expressions of measured impedance under normal operation and fault conditions are deduced based on rigorous and accurate line model.Based on the expressions,the characteristics of the measured impedance are calculated and analyzed.With the characteristics of the measured impedance,the applicability of the protection with the traditional threshold value is further discussed and the distribution of the dead zone can be located.Then,the method to calculate the threshold value of ELIS-based protection is proposed.With a proper threshold value selected by the proposed method,the dead zone of ELIS-based protection is effectively eliminated,and the protection can identify all types of faults even with large transition resistances.Case studies on PSCAD/EMTDC have been conducted to verify the conclusion.
文摘Cochlear duct length (CDL) measurement or estimation is a hot topic for various research groups in the cochlear implant (CI) field as of today.Getting the CDL along the outer wall (LW) and organ of corti (OC) is possible but considering the clinical application especially in the selection of the electrode array length and applying Greenwood's frequency function,we need to have a clear understanding on the CDL in general and as well on the Greenwood's frequency function.It is very clear from the histology images of the cochlea with straight electrode inside,that the electrode locates itself right under the basilar membrane.Also the Greenwood's frequency function involves a variable that corresponds to the CDL at the basilar membrane/organ of corti level This brings us to conclude that the CDL at the OC is relevant for the selection of electrode array length and in applying Greenwood's frequency function.The ratio between CDL (LW) and CDL (OC) is 0.9 which is a very important number that needs to be remembered when converting CDL (LW) to CDL (OC).