This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2D...This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2DM group) and 40 healthy volunteers (NC group) were recruited. The intima-media thickness (IMT), the inner diameter and the perfusion of dorsal artery of foot were measured by using high-frequency ultrasonograpy. Meanwhile, the parameters of vascular elasticity, including stiffness parameter (]3), pressure-strain elastic modulus (Ep), arterial compliance (AC), augment index (AI), and pulse wave conducting velocity (PWV]3) were detected by means of echo-tracking technique. The results showed that no significant difference was found in the IMT, systolic diameter (Ds), diastolic diameter (Dd) and peak systolic velocity (PSV) between T2DM and NC groups. Ep and PWVβ were increased, and AC was decreased in T2DM group as compared with those in NC group with the differences being significant (P〈0.05 for all). There was no significant difference in β and AI between T2DM and NC groups. It was concluded that high-frequency ultra- sonography in combination with echo-tracking technique is sensitive and non-invasive, and can be used for early detection of sclerosis of the lower extremity artery in patients with type 2 MD.展开更多
AIM:To investigate the diagnostic accuracy of acoustic radiation force impulse (ARFI) imaging as a noninvasive method for the assessment of liver fibrosis in chronic hepatitis C (CHC) patients.METHODS:We performed a p...AIM:To investigate the diagnostic accuracy of acoustic radiation force impulse (ARFI) imaging as a noninvasive method for the assessment of liver fibrosis in chronic hepatitis C (CHC) patients.METHODS:We performed a prospective blind com-parison of ARFI elastography,APRI index and FibroMax in a consecutive series of patients who underwent liver biopsy for CHC in University Hospital Bucharest. His-topathological staging of liver fibrosis according to the METAVIR scoring system served as the reference. A to-tal of 74 patients underwent ARFI elastography,APRI index,FibroMax and successful liver biopsy. RESULTS:The noninvasive tests had a good correlation with the liver biopsy results. The most powerful test in predicting fibrosis was ARFI elastography. The diagnostic accuracy of ARFI elastography,expressedas area under receiver operating characteristic curve (AUROC) had a validity of 90.2% (95% CI AUROC = 0.831-0.972,P < 0.001) for the diagnosis of significant f ibrosis (F ≥ 2). ARFI sonoelastography predicted even better F3 or F4 fibrosis (AUROC = 0.993,95% CI = 0.979-1).CONCLUSION:ARFI elastography had very good accuracy for the assessment of liver fibrosis and was superior to other noninvasive methods (APRI Index,FibroMax) for staging liver fibrosis.展开更多
文摘This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2DM group) and 40 healthy volunteers (NC group) were recruited. The intima-media thickness (IMT), the inner diameter and the perfusion of dorsal artery of foot were measured by using high-frequency ultrasonograpy. Meanwhile, the parameters of vascular elasticity, including stiffness parameter (]3), pressure-strain elastic modulus (Ep), arterial compliance (AC), augment index (AI), and pulse wave conducting velocity (PWV]3) were detected by means of echo-tracking technique. The results showed that no significant difference was found in the IMT, systolic diameter (Ds), diastolic diameter (Dd) and peak systolic velocity (PSV) between T2DM and NC groups. Ep and PWVβ were increased, and AC was decreased in T2DM group as compared with those in NC group with the differences being significant (P〈0.05 for all). There was no significant difference in β and AI between T2DM and NC groups. It was concluded that high-frequency ultra- sonography in combination with echo-tracking technique is sensitive and non-invasive, and can be used for early detection of sclerosis of the lower extremity artery in patients with type 2 MD.
基金Supported by Grant 41066/2007, financed by the Ministry of Education and Research
文摘AIM:To investigate the diagnostic accuracy of acoustic radiation force impulse (ARFI) imaging as a noninvasive method for the assessment of liver fibrosis in chronic hepatitis C (CHC) patients.METHODS:We performed a prospective blind com-parison of ARFI elastography,APRI index and FibroMax in a consecutive series of patients who underwent liver biopsy for CHC in University Hospital Bucharest. His-topathological staging of liver fibrosis according to the METAVIR scoring system served as the reference. A to-tal of 74 patients underwent ARFI elastography,APRI index,FibroMax and successful liver biopsy. RESULTS:The noninvasive tests had a good correlation with the liver biopsy results. The most powerful test in predicting fibrosis was ARFI elastography. The diagnostic accuracy of ARFI elastography,expressedas area under receiver operating characteristic curve (AUROC) had a validity of 90.2% (95% CI AUROC = 0.831-0.972,P < 0.001) for the diagnosis of significant f ibrosis (F ≥ 2). ARFI sonoelastography predicted even better F3 or F4 fibrosis (AUROC = 0.993,95% CI = 0.979-1).CONCLUSION:ARFI elastography had very good accuracy for the assessment of liver fibrosis and was superior to other noninvasive methods (APRI Index,FibroMax) for staging liver fibrosis.