Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/ impedance and to estimate the potential distribution in the vicinity of earth electrodes.However,very little ...Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/ impedance and to estimate the potential distribution in the vicinity of earth electrodes.However,very little literature is available on experimental validation of these calculation techniques.To address this,a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales.In this paper,the earthing test facility at Dinorwig power station is described including the details of the experimental set up.The results from experimental tests on a 5 mX5 m earth grid,immersed in water and energized under ac,dc and impulse,are presented.The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.展开更多
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche...DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results.展开更多
文摘Analytical and numerical simulation techniques have been developed for the calculation of earth resistance/ impedance and to estimate the potential distribution in the vicinity of earth electrodes.However,very little literature is available on experimental validation of these calculation techniques.To address this,a programme of experimental tests on various earth electrodes has been carried out at the lower water reservoir of a hydro pumped-storage power station in North Wales.In this paper,the earthing test facility at Dinorwig power station is described including the details of the experimental set up.The results from experimental tests on a 5 mX5 m earth grid,immersed in water and energized under ac,dc and impulse,are presented.The values of measured earth resistance/impedance and water surface potential distributions are compared with those obtained from analytical calculations and detailed numerical computer simulations.
文摘DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results.