An artificial neural network(ANN)method is introduced to predict drop size in two kinds of pulsed columns with small-scale data sets.After training,the deviation between calculate and experimental results are 3.8%and ...An artificial neural network(ANN)method is introduced to predict drop size in two kinds of pulsed columns with small-scale data sets.After training,the deviation between calculate and experimental results are 3.8%and 9.3%,respectively.Through ANN model,the influence of interfacial tension and pulsation intensity on the droplet diameter has been developed.Droplet size gradually increases with the increase of interfacial tension,and decreases with the increase of pulse intensity.It can be seen that the accuracy of ANN model in predicting droplet size outside the training set range is reach the same level as the accuracy of correlation obtained based on experiments within this range.For two kinds of columns,the drop size prediction deviations of ANN model are 9.6%and 18.5%and the deviations in correlations are 11%and 15%.展开更多
Taking into account the effect of velocity profiles of the continuous phase in interstices of drops,dragcoefficient and relative motion correlations for dispersed liquid-liquid two-phase flow in absence of mass transf...Taking into account the effect of velocity profiles of the continuous phase in interstices of drops,dragcoefficient and relative motion correlations for dispersed liquid-liquid two-phase flow in absence of mass transferwere developed in terms of the pseudo-fluid concept based on the simple similarity criteria and the mixtureviscosity model suggested by Ishii and Zuber.The present model was compared with the experimental data fromfive(different sources and also with seven other pertinent correlations available in literature.Fairly goodpredictions were obtained under wide ranges of the dispersed phase holdup and Reynolds number.The validity ofthe present model has also been checked against the experimental slip velocity data and holdup data obtained ina Karr reciprocating plate extraction column by the author of the present paper and satisfactory agreement isachieved、The results show that the equations of the motion of a multi-droplet system can be formulated in aform identical with those for a single展开更多
The focus of this research is a new type of particle extraction process for the transfer of magnetite nanoparticles from an aqueous to an immiscible organic phase, directly through the liquid-liquid phase boundary in ...The focus of this research is a new type of particle extraction process for the transfer of magnetite nanoparticles from an aqueous to an immiscible organic phase, directly through the liquid-liquid phase boundary in a drop column. The particle extraction process comprises several advantages such as a minimum amount of stabilizing surfactant, no exposure of the particles to a gas atmosphere and with it the avoidance of sintering by capillary forces and a high particle concentration in the receiving phase as well. The study presents experimental results of the characterization of the process environment and the transfer behavior in a drop column. The solution of surfactant in the continuous phase has been investigated during a particle-free phase transfer experiment including the measurements of the total organic carbon (TOC) content and analysis of the size of the stabilized droplets using the laser diffraction spectroscopy. The determination of the transfer fluxes, the mass flows as well as the yield of transferred magnetite by ICP-OES measurements provide information on the impact of interaction of the elementary processes at the phase boundary. Furthermore, the transfer kinetics of the process is described and compared with calculated theoretical values resulting from a kinetic approach.展开更多
The extraction kinetics of Gd(III) from the nitric acid medium using bis(2,4,4-trimethylpentyl) dithio- phosphinic acid (Cyanex301) and 2-ethylhexyl phosphoric acid (D2EHPA) in kerosene solution were measured ...The extraction kinetics of Gd(III) from the nitric acid medium using bis(2,4,4-trimethylpentyl) dithio- phosphinic acid (Cyanex301) and 2-ethylhexyl phosphoric acid (D2EHPA) in kerosene solution were measured by the single drop technique. The influences of hydrogen ion concentration, gadolinium ion concentration, extractant concentration, column height, and nozzle diameter on the extraction rate were investigated. The forward rate equations for the gadolinium extraction with D2EHPA and Cyanex301 were obtained. Based on the experimental results, the forward extraction rate constant was calculated. With the increase of D2EHPA or Cyanex301 concentration, the drop rising diameter and the value of interfacial tension decrease in the studied system, which shows that D2EHPA or Cyanex301 has interfacial activity as a kind of surfactant. Also, the droplet diameter and interfacial tension decrease with the increase of aqueous solution acidity. The experimental results show that the D2EHPA extractant provides faster extraction rate in comparison with Cyanex301 extractant, and it would be useful in industrial continuous extraction process.展开更多
The experiment was conducted to explore the hydrodynamics in a conical column with a height of 3.00 m, and a taper angle of 1.91°. Three regimes occur in succession with increasing superficial gas velocity. Ove...The experiment was conducted to explore the hydrodynamics in a conical column with a height of 3.00 m, and a taper angle of 1.91°. Three regimes occur in succession with increasing superficial gas velocity. Overall gas holdup increases with an increase in gas velocity and a decrease in solid concentration or static slurry height. Axial solid holdup becomes more uniform with increasing gas velocity, while axial gas holdup decreases from the bottom to the top. Both dry and wet pressure drops across the gas distributor increase with an increase in superficial gas velocity.展开更多
基金the support of the National Natural Science Foundation of China(22278234,21776151)。
文摘An artificial neural network(ANN)method is introduced to predict drop size in two kinds of pulsed columns with small-scale data sets.After training,the deviation between calculate and experimental results are 3.8%and 9.3%,respectively.Through ANN model,the influence of interfacial tension and pulsation intensity on the droplet diameter has been developed.Droplet size gradually increases with the increase of interfacial tension,and decreases with the increase of pulse intensity.It can be seen that the accuracy of ANN model in predicting droplet size outside the training set range is reach the same level as the accuracy of correlation obtained based on experiments within this range.For two kinds of columns,the drop size prediction deviations of ANN model are 9.6%and 18.5%and the deviations in correlations are 11%and 15%.
文摘Taking into account the effect of velocity profiles of the continuous phase in interstices of drops,dragcoefficient and relative motion correlations for dispersed liquid-liquid two-phase flow in absence of mass transferwere developed in terms of the pseudo-fluid concept based on the simple similarity criteria and the mixtureviscosity model suggested by Ishii and Zuber.The present model was compared with the experimental data fromfive(different sources and also with seven other pertinent correlations available in literature.Fairly goodpredictions were obtained under wide ranges of the dispersed phase holdup and Reynolds number.The validity ofthe present model has also been checked against the experimental slip velocity data and holdup data obtained ina Karr reciprocating plate extraction column by the author of the present paper and satisfactory agreement isachieved、The results show that the equations of the motion of a multi-droplet system can be formulated in aform identical with those for a single
文摘The focus of this research is a new type of particle extraction process for the transfer of magnetite nanoparticles from an aqueous to an immiscible organic phase, directly through the liquid-liquid phase boundary in a drop column. The particle extraction process comprises several advantages such as a minimum amount of stabilizing surfactant, no exposure of the particles to a gas atmosphere and with it the avoidance of sintering by capillary forces and a high particle concentration in the receiving phase as well. The study presents experimental results of the characterization of the process environment and the transfer behavior in a drop column. The solution of surfactant in the continuous phase has been investigated during a particle-free phase transfer experiment including the measurements of the total organic carbon (TOC) content and analysis of the size of the stabilized droplets using the laser diffraction spectroscopy. The determination of the transfer fluxes, the mass flows as well as the yield of transferred magnetite by ICP-OES measurements provide information on the impact of interaction of the elementary processes at the phase boundary. Furthermore, the transfer kinetics of the process is described and compared with calculated theoretical values resulting from a kinetic approach.
基金financially supported by the Iran National Science Foundation(INSF)(No.90005452)
文摘The extraction kinetics of Gd(III) from the nitric acid medium using bis(2,4,4-trimethylpentyl) dithio- phosphinic acid (Cyanex301) and 2-ethylhexyl phosphoric acid (D2EHPA) in kerosene solution were measured by the single drop technique. The influences of hydrogen ion concentration, gadolinium ion concentration, extractant concentration, column height, and nozzle diameter on the extraction rate were investigated. The forward rate equations for the gadolinium extraction with D2EHPA and Cyanex301 were obtained. Based on the experimental results, the forward extraction rate constant was calculated. With the increase of D2EHPA or Cyanex301 concentration, the drop rising diameter and the value of interfacial tension decrease in the studied system, which shows that D2EHPA or Cyanex301 has interfacial activity as a kind of surfactant. Also, the droplet diameter and interfacial tension decrease with the increase of aqueous solution acidity. The experimental results show that the D2EHPA extractant provides faster extraction rate in comparison with Cyanex301 extractant, and it would be useful in industrial continuous extraction process.
文摘The experiment was conducted to explore the hydrodynamics in a conical column with a height of 3.00 m, and a taper angle of 1.91°. Three regimes occur in succession with increasing superficial gas velocity. Overall gas holdup increases with an increase in gas velocity and a decrease in solid concentration or static slurry height. Axial solid holdup becomes more uniform with increasing gas velocity, while axial gas holdup decreases from the bottom to the top. Both dry and wet pressure drops across the gas distributor increase with an increase in superficial gas velocity.