A new digital communication technology based on the Phase-Offset Overlapped Waves (POOW) has been introduced in this letter. The waves can be considered as a special multicarrier different from traditional ones. The s...A new digital communication technology based on the Phase-Offset Overlapped Waves (POOW) has been introduced in this letter. The waves can be considered as a special multicarrier different from traditional ones. The sub-waves in a coded word's period of the POOW are sine waves and have the same frequencies, but different starting phases. The most important characteristic is that these sub-waves are the piecewise functions and not orthogonal in a code word period. The decoding can be implemented by solving a linear equation group. This code has very high efficiency and thus the data transmission rate is increased greatly.展开更多
In clinical practice, dentists sometimes encounter phenomena that cannot be explained by modern western medical concepts;for example, the patient’s medical symptoms improve by bringing medicines or dentures close to ...In clinical practice, dentists sometimes encounter phenomena that cannot be explained by modern western medical concepts;for example, the patient’s medical symptoms improve by bringing medicines or dentures close to the body. Although it seems difficult to completely elucidate the mechanism through modern western medicine, it can be explained using quantum mechanics. The quantum, the smallest unit of matter composition, exhibits wave-particle duality. The fact that symptoms can be improved simply by bringing dentures or medicines closer to the body indicates that the waves emitted by dentures or medicines interfere with the pathological waves emitted by the pathological site. Thus, the pathological waves are deformed and lead to a change in symptoms. In this way, quantum theory can explain phenomena that are difficult to elucidate in conventional medicine, which are encountered in clinical practice. So far, the author has presented a case of difficulty in raising the upper limb where the symptoms improved without the need for dentures in the mouth by adjusting the dentures outside the mouth. This time, the author would like to introduce a case which the patient’s knee pain improved by adjusting the dentures outside the mouth.展开更多
微波功率模块是美国国防部电子器件咨询小组提出的一种新概念功率器件,适应雷达、电子战系统的需求。本文介绍了一种数字化毫米波微波功率模块(Microwave Power Module,MPM)的系统组成及关键技术。分析了模块采用独立控制和集中控制两...微波功率模块是美国国防部电子器件咨询小组提出的一种新概念功率器件,适应雷达、电子战系统的需求。本文介绍了一种数字化毫米波微波功率模块(Microwave Power Module,MPM)的系统组成及关键技术。分析了模块采用独立控制和集中控制两种方式的优缺点。论述了全数字微波功率模块的数字化设计,包含数字化高压电源、数字化幅相控制和数字化控制保护等关键模块。详细论述了数字化控制保护的组成、接口、定时控制、稳压控制及控制保护软件。最后对研制成功的数字化毫米波微波功率模块进行了测试,测试结果表明,输出功率、波形和带宽均达到了设计指标的要求。展开更多
In mmWave massive multiple-input multiple-output(MIMO)communication systems,the extension of low-complexity narrowband precoding schemes to be operated on wideband systems under frequency-selective channels remains an...In mmWave massive multiple-input multiple-output(MIMO)communication systems,the extension of low-complexity narrowband precoding schemes to be operated on wideband systems under frequency-selective channels remains an important challenge at the current time.This paper investigates a low complexity wideband hybrid precoding scheme for mmWave massive MIMO multicarrier systems under a single-user,fully-connected hybrid architecture.We show that the radio frequency(RF)precoding/combining vectors can be directly derived from the eigenvectors of the optimal fully-digital covariance matrix over all subcarriers in order to maximize the sum rate of spectral efficiency.We also suggest a new method that iteratively reduces the residual error between the covariance matrix and the sum of products of precoding matrices over all the subcarriers to improve the performance in the case where the number of RF chains is higher than the number of streams.The results of the simulation show that the proposed schemes’complexity is low compared to the present methods,and their performance can almost reach the upper bound achieved by the optimal full-baseband design.展开更多
In this article,a single-board integrated millimeter-wave(mm-Wave)asymmetric full-digital beamforming(AFDBF)array is developed for beyond-fifth-generation(B5G)and sixth-generation(6G)communications.The proposed integr...In this article,a single-board integrated millimeter-wave(mm-Wave)asymmetric full-digital beamforming(AFDBF)array is developed for beyond-fifth-generation(B5G)and sixth-generation(6G)communications.The proposed integrated array effectively addresses the challenge of arranging a large number of ports in a full-digital array by designing vertical connections in a three-dimensional space and successfully integrating full-digital transmitting(Tx)and receiving(Rx)arrays independently in a single board.Unlike the traditional symmetric array,the proposed asymmetric array is composed of an 8×8 Tx array arranged in a square shape and an 8+8 Rx array arranged in an L shape.The center-to-center distance between two adjacent elements is 0.54k0 for both the Tx and Rx arrays,where k0 is the free-space wavelength at 27 GHz.The proposed AFDBF array possesses a more compact structure and lower system hardware cost and power consumption compared with conventional brick-type full-digital arrays.In addition,the energy efficiency of the proposed AFDBF array outperforms that of a hybrid beamforming array.The measurement results indicate that the operating frequency band of the proposed array is 24.25–29.50 GHz.An eight-element linear array within the Tx array can achieve a scanning angle ranging from-47°to+47°in both the azimuth and the elevation planes,and the measured scanning range of each eight-element Rx array is–45°to+45°.The measured maximum effective isotropic radiated power(EIRP)of the eight-element Tx array is 43.2 dBm at 28.0 GHz(considering the saturation point).Furthermore,the measured error vector magnitude(EVM)is less than 3%when 64-quadrature amplitude modulation(QAM)waveforms are used.展开更多
文摘A new digital communication technology based on the Phase-Offset Overlapped Waves (POOW) has been introduced in this letter. The waves can be considered as a special multicarrier different from traditional ones. The sub-waves in a coded word's period of the POOW are sine waves and have the same frequencies, but different starting phases. The most important characteristic is that these sub-waves are the piecewise functions and not orthogonal in a code word period. The decoding can be implemented by solving a linear equation group. This code has very high efficiency and thus the data transmission rate is increased greatly.
文摘In clinical practice, dentists sometimes encounter phenomena that cannot be explained by modern western medical concepts;for example, the patient’s medical symptoms improve by bringing medicines or dentures close to the body. Although it seems difficult to completely elucidate the mechanism through modern western medicine, it can be explained using quantum mechanics. The quantum, the smallest unit of matter composition, exhibits wave-particle duality. The fact that symptoms can be improved simply by bringing dentures or medicines closer to the body indicates that the waves emitted by dentures or medicines interfere with the pathological waves emitted by the pathological site. Thus, the pathological waves are deformed and lead to a change in symptoms. In this way, quantum theory can explain phenomena that are difficult to elucidate in conventional medicine, which are encountered in clinical practice. So far, the author has presented a case of difficulty in raising the upper limb where the symptoms improved without the need for dentures in the mouth by adjusting the dentures outside the mouth. This time, the author would like to introduce a case which the patient’s knee pain improved by adjusting the dentures outside the mouth.
文摘微波功率模块是美国国防部电子器件咨询小组提出的一种新概念功率器件,适应雷达、电子战系统的需求。本文介绍了一种数字化毫米波微波功率模块(Microwave Power Module,MPM)的系统组成及关键技术。分析了模块采用独立控制和集中控制两种方式的优缺点。论述了全数字微波功率模块的数字化设计,包含数字化高压电源、数字化幅相控制和数字化控制保护等关键模块。详细论述了数字化控制保护的组成、接口、定时控制、稳压控制及控制保护软件。最后对研制成功的数字化毫米波微波功率模块进行了测试,测试结果表明,输出功率、波形和带宽均达到了设计指标的要求。
文摘In mmWave massive multiple-input multiple-output(MIMO)communication systems,the extension of low-complexity narrowband precoding schemes to be operated on wideband systems under frequency-selective channels remains an important challenge at the current time.This paper investigates a low complexity wideband hybrid precoding scheme for mmWave massive MIMO multicarrier systems under a single-user,fully-connected hybrid architecture.We show that the radio frequency(RF)precoding/combining vectors can be directly derived from the eigenvectors of the optimal fully-digital covariance matrix over all subcarriers in order to maximize the sum rate of spectral efficiency.We also suggest a new method that iteratively reduces the residual error between the covariance matrix and the sum of products of precoding matrices over all the subcarriers to improve the performance in the case where the number of RF chains is higher than the number of streams.The results of the simulation show that the proposed schemes’complexity is low compared to the present methods,and their performance can almost reach the upper bound achieved by the optimal full-baseband design.
基金supported by the National Key Research and Development Program of China(2020YFB1804900 and 2022YFE0210900)the Fundamental Research Funds for the Central Universities(2242022k60008 and 2242022k30003)+2 种基金the National Natural Science Foundation of China(62301152 and 61627801)the Youth Talent Promotion Foundation of Jiangsu Science and Technology Association(TJ-2023-074)the Startup Research Fund of Southeast University(RF1028623286).
文摘In this article,a single-board integrated millimeter-wave(mm-Wave)asymmetric full-digital beamforming(AFDBF)array is developed for beyond-fifth-generation(B5G)and sixth-generation(6G)communications.The proposed integrated array effectively addresses the challenge of arranging a large number of ports in a full-digital array by designing vertical connections in a three-dimensional space and successfully integrating full-digital transmitting(Tx)and receiving(Rx)arrays independently in a single board.Unlike the traditional symmetric array,the proposed asymmetric array is composed of an 8×8 Tx array arranged in a square shape and an 8+8 Rx array arranged in an L shape.The center-to-center distance between two adjacent elements is 0.54k0 for both the Tx and Rx arrays,where k0 is the free-space wavelength at 27 GHz.The proposed AFDBF array possesses a more compact structure and lower system hardware cost and power consumption compared with conventional brick-type full-digital arrays.In addition,the energy efficiency of the proposed AFDBF array outperforms that of a hybrid beamforming array.The measurement results indicate that the operating frequency band of the proposed array is 24.25–29.50 GHz.An eight-element linear array within the Tx array can achieve a scanning angle ranging from-47°to+47°in both the azimuth and the elevation planes,and the measured scanning range of each eight-element Rx array is–45°to+45°.The measured maximum effective isotropic radiated power(EIRP)of the eight-element Tx array is 43.2 dBm at 28.0 GHz(considering the saturation point).Furthermore,the measured error vector magnitude(EVM)is less than 3%when 64-quadrature amplitude modulation(QAM)waveforms are used.