期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Study on regurgitation of a bearing-less mini axial aortic valvo-pump with closed impeller
1
作者 Kun-Xi Qian 《Health》 2009年第3期173-175,共3页
The back-flow of an aortic valvo-pump will re-duce the pumping flow rate but can wash out the gap between the rotor and the stator, and thus can improve the antithrombogenicity of the de-vice. To investigate the regur... The back-flow of an aortic valvo-pump will re-duce the pumping flow rate but can wash out the gap between the rotor and the stator, and thus can improve the antithrombogenicity of the de-vice. To investigate the regurgitation of a 23mm OD aortic valvo-pump, its closed impeller was replaced by a cylinder and hereby the valvo- pump had lost its pumping function. The pres-sure head crossing the aortic valvo-pump was maintained by a locally made pulsatile centrifugal pump, beating rhythmically from 30 to 120mmHg. The back flow from outlet to inlet of valvo-pump via the above-mentioned gap was measured. Results demonstrated that this gap and the pressure head had remarkable effect on back- flow;a larger gap and/or a larger pressure head would lead to a larger back-flow. By 0,20mm gap and 100mmHg pressure head, the valvo-pump had ca. 0,8 l/min back-flow. Instantaneous meas-urement indicated that the back-flow had a pul-satile form with high rate during diastole while low rate during systole of the natural heart imi-tated by pulsatile centrifugal pump. The pump rotated at 12500rpm, 15000rpm and 17500rpm respectively, but it was found the rotating speed had no affection on back-flow. This investigation provides a basis for pump design seeking for both increase of the flow rate and improvement of the compatibility;the former is particularly important for a mini axial pump and the latter is extremely difficult for closed impeller. 展开更多
关键词 AORTIC Valvo-Pump REGURGITATION Measurement different air-gap and pressure head Anti-Thrombogenicity
下载PDF
主动脉瓣膜泵的回流
2
作者 钱坤喜 茹伟民 +3 位作者 曾培 王芳群 王颢 袁海宇 《江苏大学学报(自然科学版)》 EI CAS 北大核心 2006年第5期434-436,共3页
为了研究主动脉瓣膜泵的回流,将血泵内的叶轮换成圆柱体,使血泵失去泵血的作用,从而进行回流测试.测试中,血泵分别以15000r/min,17500r/min和20000r/min的转速旋转,出口与进口之间的压力差由一个离心泵提供,用流量计测出从... 为了研究主动脉瓣膜泵的回流,将血泵内的叶轮换成圆柱体,使血泵失去泵血的作用,从而进行回流测试.测试中,血泵分别以15000r/min,17500r/min和20000r/min的转速旋转,出口与进口之间的压力差由一个离心泵提供,用流量计测出从瓣膜泵出口经定、转子间气隙到进口的回流.试验结果表明气隙和压差对回流有明显影响:增大气隙或增大压差都会导致回流的增加.当气隙为0.20mm,进出口压差为13.3kPa时,瓣膜泵的回流为0.6—0.8L/min.回流随时间变化的曲线图表明,在自然心脏舒张期回流产生一个波峰,而在收缩期产生一个波谷.瓣膜泵的转速对回流无明显影响,当转速增大时回流只有略微的下降. 展开更多
关键词 主动脉瓣膜泵 回流测量 气隙和压差 抗血栓形成
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部