The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments wi...The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.展开更多
This paper shows the R&D results of the power supply system in 2006, including the application of speed control assemblies of two 80 MVA MG sets, the modification of the exciting field system, the development of the ...This paper shows the R&D results of the power supply system in 2006, including the application of speed control assemblies of two 80 MVA MG sets, the modification of the exciting field system, the development of the new HV modulators in ECRH system, the update of several poloidal power supplies. It also presents the status of the power suppIy system in HL-2A experimental operation and foresees the power and energy requirements for new power supply system at HL-2M device.展开更多
针对空间再生燃料电池能源系统的用电和环境要求,对其关键部件大功率双向DC变换器进行了研究。为保证苛刻环境下DC变换器可靠工作,对变换器结构、功率器件进行了热分析、热模拟,并在模拟空间环境中进行了验证。根据系统工作特点,进行水...针对空间再生燃料电池能源系统的用电和环境要求,对其关键部件大功率双向DC变换器进行了研究。为保证苛刻环境下DC变换器可靠工作,对变换器结构、功率器件进行了热分析、热模拟,并在模拟空间环境中进行了验证。根据系统工作特点,进行水电一体化功率结构设计,优化电路拓扑,以满足空间对质量、体积和效率的高要求。最后对60 k W双向DC变换器样机进行了测试,测试表明该变换器满足设计要求。展开更多
In this paper, the solar panels are used to power an electrolyzer to separate the water into hydrogen and oxygen gas. Theelectrical equivalent circuit for the proton exchange membrane electrolyzer was developed and im...In this paper, the solar panels are used to power an electrolyzer to separate the water into hydrogen and oxygen gas. Theelectrical equivalent circuit for the proton exchange membrane electrolyzer was developed and implemented in MATLAB/Simulinkalong with the atmospheric hydrogen storage tank. The voltage (2 volt) and current (1 ampere) were supplied in a similar manner inorder to compare the simulated and experimental results. The hydrogen amount is calculated to be 7.345 (ml/min A) from the modelas well as the experimental set-up. The experimental and simulation results were matched.展开更多
The operating circuits for LED (light emitting diode) lamp composed of diodes and DC capacitors only are proposed. The proposed circuit is based on a double-voltage rectifier circuit and a Cockcroft-Walton circuit. ...The operating circuits for LED (light emitting diode) lamp composed of diodes and DC capacitors only are proposed. The proposed circuit is based on a double-voltage rectifier circuit and a Cockcroft-Walton circuit. The circuit can operate LED without flicker, and is free from switching noise since high frequency switching circuit is not used. To replace an AC capacitor by a DC capacitor for the ballast, a diode is connected across the capacitor in parallel, and the operating voltage of LED unit is kept at the value greater than the peak voltage of the input power source. The circuit realizes high efficiency and high input power factor compared with the operating circuits on the market. Cockcroft-Walton-type circuit can operate many LED devices in series connection. Series connection is preferable for fabricating LED unit of a constant voltage characteristic. Moreover, fairly flat waveform of LED operating current is realized by Cockcrofl-Walton-type circuit, even though capacitor ballast is used.展开更多
基金Project supported by National Basic Research Program of China(973 Program) (2011CB 209400)Program of State Key Laboratory of Power Systems for ±1 100 kV UHVDC Technology(SKLD10M09)
文摘The valve side windings of converter transformers bear AC, DC, impulse, and reversal-polarity voltages during operation, which could result in serious insulation problems of the equipment. By performing experiments with surface discharge model of oil-paper insula- tion at 80 ℃ under combined AC-DC voltage for 200 h, we studied the spectrums and statistical parameters of partial discharges at different discharge stages. Furthermore, some fingerprint parameters were calculated in order to estimate the development situation of par- tial discharge, while the characteristic gases dissolved in the transformer oil were measured by gas chromatography. The surface discharges in the experiments were observed using a high speed camera, and a full discharge process could be marked off into four stages as follows. ①The elementary stage. When a partial discharge occurs near electrodes, electrical charges are injected into the region near electrodes and causing bubble generation. ②Due to their high resistivity and low dielectric constant, the bubbles would bare the major part of the voltage applied to samples. Therefore, discharge happens inside the small bubbles, and it emits a lot of light. ③Micromolecules of gas are produced in discharge, and further ionization in the transformer oil takes place simultaneously when high-energy electrons collide with oil molecules. ④The carrier charge moves forward to electrodes driven by the applied electric field, till they neutralize with the charge from electrodes, and hence discharge channels are formed subsequently.
文摘This paper shows the R&D results of the power supply system in 2006, including the application of speed control assemblies of two 80 MVA MG sets, the modification of the exciting field system, the development of the new HV modulators in ECRH system, the update of several poloidal power supplies. It also presents the status of the power suppIy system in HL-2A experimental operation and foresees the power and energy requirements for new power supply system at HL-2M device.
文摘针对空间再生燃料电池能源系统的用电和环境要求,对其关键部件大功率双向DC变换器进行了研究。为保证苛刻环境下DC变换器可靠工作,对变换器结构、功率器件进行了热分析、热模拟,并在模拟空间环境中进行了验证。根据系统工作特点,进行水电一体化功率结构设计,优化电路拓扑,以满足空间对质量、体积和效率的高要求。最后对60 k W双向DC变换器样机进行了测试,测试表明该变换器满足设计要求。
文摘In this paper, the solar panels are used to power an electrolyzer to separate the water into hydrogen and oxygen gas. Theelectrical equivalent circuit for the proton exchange membrane electrolyzer was developed and implemented in MATLAB/Simulinkalong with the atmospheric hydrogen storage tank. The voltage (2 volt) and current (1 ampere) were supplied in a similar manner inorder to compare the simulated and experimental results. The hydrogen amount is calculated to be 7.345 (ml/min A) from the modelas well as the experimental set-up. The experimental and simulation results were matched.
文摘The operating circuits for LED (light emitting diode) lamp composed of diodes and DC capacitors only are proposed. The proposed circuit is based on a double-voltage rectifier circuit and a Cockcroft-Walton circuit. The circuit can operate LED without flicker, and is free from switching noise since high frequency switching circuit is not used. To replace an AC capacitor by a DC capacitor for the ballast, a diode is connected across the capacitor in parallel, and the operating voltage of LED unit is kept at the value greater than the peak voltage of the input power source. The circuit realizes high efficiency and high input power factor compared with the operating circuits on the market. Cockcroft-Walton-type circuit can operate many LED devices in series connection. Series connection is preferable for fabricating LED unit of a constant voltage characteristic. Moreover, fairly flat waveform of LED operating current is realized by Cockcrofl-Walton-type circuit, even though capacitor ballast is used.