Field studies were conducted at Hisar during Kharif, 2009-2010 and 2010-2011 under natural and unsprayed condition. RCH 134 Bt, HS 6 (non Bt), H 1117 and Ganganagar Ageti (non Bt) were selected for the studies. The ex...Field studies were conducted at Hisar during Kharif, 2009-2010 and 2010-2011 under natural and unsprayed condition. RCH 134 Bt, HS 6 (non Bt), H 1117 and Ganganagar Ageti (non Bt) were selected for the studies. The experiment was laid down in Randomized Block Design replicated thrice having plant spacing 67.5 × 60 cm. Among the bollworms, Erias spp. exhibited positive correlation with rainfall, minimum temperature and relative humidity morning hours significantly at 5 percent level whereas Helicoverpa and Pectinophora displayed positive relations only with evening hours relative humidity significantly while Spodoptera were significantly positive correlated with relative humidity of morning and evening hours. Bollworm complex was negatively correlated with all the weather parameters employed to study although being non-significant in case of rainfall, maximum and minimum of temperature, morning and evening hours of relative humidity. Among the sucking pests, leafhoppers, whitefly, thrips and aphids population showed significantly negative correlation with weather parameters. The comparison of natural bio-agents in cotton hybrids under study revealed that overall mean population of natural enemies were higher in Bt cotton hybrid as compared to non-Bt. These results confirm that use of genetically modified (Bt) cotton in lieu of conventional genotypes could positively impact non-target and beneficial insect species by preserving their host populations.展开更多
Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an...Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electromechanical forces occurring from the fault currents or due to Transformer transportation and relocation. In this method, the frequency response of a transformer is taken both at manufacturing industry and concern site. Then both the response is compared to predict the fault taken place in active part. But in old aged transformers, the primary reference response is unavailable. So Cross Correlation Co-Efficient (CCF) measurement technique can be a vital process for fault detection in these transformers. In this paper, theoretical background of SFRA technique has been elaborated and through several case studies, the effectiveness of CCF parameter for fault detection has been represented.展开更多
文摘Field studies were conducted at Hisar during Kharif, 2009-2010 and 2010-2011 under natural and unsprayed condition. RCH 134 Bt, HS 6 (non Bt), H 1117 and Ganganagar Ageti (non Bt) were selected for the studies. The experiment was laid down in Randomized Block Design replicated thrice having plant spacing 67.5 × 60 cm. Among the bollworms, Erias spp. exhibited positive correlation with rainfall, minimum temperature and relative humidity morning hours significantly at 5 percent level whereas Helicoverpa and Pectinophora displayed positive relations only with evening hours relative humidity significantly while Spodoptera were significantly positive correlated with relative humidity of morning and evening hours. Bollworm complex was negatively correlated with all the weather parameters employed to study although being non-significant in case of rainfall, maximum and minimum of temperature, morning and evening hours of relative humidity. Among the sucking pests, leafhoppers, whitefly, thrips and aphids population showed significantly negative correlation with weather parameters. The comparison of natural bio-agents in cotton hybrids under study revealed that overall mean population of natural enemies were higher in Bt cotton hybrid as compared to non-Bt. These results confirm that use of genetically modified (Bt) cotton in lieu of conventional genotypes could positively impact non-target and beneficial insect species by preserving their host populations.
文摘Detection of minor faults in power transformer active part is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. Sweep Frequency Response Analysis (SFRA) is an effective low-voltage, off-line diagnostic tool used for finding out any possible winding displacement or mechanical deterioration inside the Transformer, due to large electromechanical forces occurring from the fault currents or due to Transformer transportation and relocation. In this method, the frequency response of a transformer is taken both at manufacturing industry and concern site. Then both the response is compared to predict the fault taken place in active part. But in old aged transformers, the primary reference response is unavailable. So Cross Correlation Co-Efficient (CCF) measurement technique can be a vital process for fault detection in these transformers. In this paper, theoretical background of SFRA technique has been elaborated and through several case studies, the effectiveness of CCF parameter for fault detection has been represented.