The compressible Rayleigh-Taylor instability of accelerated ablation front is analysed in consideration of the preheat effects, and the corresponding eigen-problem is solved numerically using the fourth-order accurate...The compressible Rayleigh-Taylor instability of accelerated ablation front is analysed in consideration of the preheat effects, and the corresponding eigen-problem is solved numerically using the fourth-order accurate two- point compact difference scheme. Both the growth rate and perturbation profiles are obtained, and the obtained growth rate is close to the results of direct numerical simulation. Our results show that the growth rate is more reduced and the cutoff wave length becomes longer as preheat increases.展开更多
The weakly nonlinear regime of single mode ablative Rayleigh-Taylor instability is studied, with consideration of preheat effect and the width of the ablation front. The Rayleigh-Taylor linear growth rate agrees well ...The weakly nonlinear regime of single mode ablative Rayleigh-Taylor instability is studied, with consideration of preheat effect and the width of the ablation front. The Rayleigh-Taylor linear growth rate agrees well with the direct numerical simulation. For the density perturbation, the amplitude distribution of the fundamental mode has one peak value whereas those of the second and third harmonics have two and three peak values, respectively. Harmonics generation versus wave number is also given and it is close to the result of direct numerical simulation.展开更多
This paper analyses a three-cavity frequency-quadrupling terahertz gyroklystron with successive frequency-doubling in each cavity with self-consistent nonlinear theory. The beam-wave interaction efficiency and the ele...This paper analyses a three-cavity frequency-quadrupling terahertz gyroklystron with successive frequency-doubling in each cavity with self-consistent nonlinear theory. The beam-wave interaction efficiency and the electron bunching process are studied. The variation of output efficiency with the length of drift tubes and output power and the variation of Ohmic loss with the length of output cavity are considered. Numerical simulations predict an optimal output efficiency of 1.8%, a power output of more than 2 kW and a gain of 33 dB after taking into account Ohmic losses when the frequency-quadrupling gyroklystron, driven by a 40-kV, 3-A electron beam and 1 Watt input power, operates at 225 CHz.展开更多
文摘The compressible Rayleigh-Taylor instability of accelerated ablation front is analysed in consideration of the preheat effects, and the corresponding eigen-problem is solved numerically using the fourth-order accurate two- point compact difference scheme. Both the growth rate and perturbation profiles are obtained, and the obtained growth rate is close to the results of direct numerical simulation. Our results show that the growth rate is more reduced and the cutoff wave length becomes longer as preheat increases.
文摘The weakly nonlinear regime of single mode ablative Rayleigh-Taylor instability is studied, with consideration of preheat effect and the width of the ablation front. The Rayleigh-Taylor linear growth rate agrees well with the direct numerical simulation. For the density perturbation, the amplitude distribution of the fundamental mode has one peak value whereas those of the second and third harmonics have two and three peak values, respectively. Harmonics generation versus wave number is also given and it is close to the result of direct numerical simulation.
基金Project supported by National Natural Science Foundation of China (Grant No 10676110)973 Program of China (Grant No2007CB310401)
文摘This paper analyses a three-cavity frequency-quadrupling terahertz gyroklystron with successive frequency-doubling in each cavity with self-consistent nonlinear theory. The beam-wave interaction efficiency and the electron bunching process are studied. The variation of output efficiency with the length of drift tubes and output power and the variation of Ohmic loss with the length of output cavity are considered. Numerical simulations predict an optimal output efficiency of 1.8%, a power output of more than 2 kW and a gain of 33 dB after taking into account Ohmic losses when the frequency-quadrupling gyroklystron, driven by a 40-kV, 3-A electron beam and 1 Watt input power, operates at 225 CHz.