An ion chromatography(IC) system coupled with on-line column-switching technique was used to determine anions ofμg/g levels in organic chemicals of analytical reagent grade.A novel polystyrene-divinylbenzene-carbon...An ion chromatography(IC) system coupled with on-line column-switching technique was used to determine anions ofμg/g levels in organic chemicals of analytical reagent grade.A novel polystyrene-divinylbenzene-carbon nanotube(PS-DVB-CNT) stationary phase was utilized for matrix elimination.A calibration study was conducted by preparing and analyzing eight concentrations(between 10 and 5000μg/L) of eight standards in deionized water.The linearity was between 0.9978 and 1.And the detection limits ranged from 1.54μg/L to 10.02μg/L.A spiking study was performed on two representative organic chemicals.The recoveries were between 84.3%and 119.6%.展开更多
This note studies fully actuated linear systems in the frequency domain in terms of polynomial matrix description(PMD).For a controllable first-order linear state-space system model,by using the right coprime factoriz...This note studies fully actuated linear systems in the frequency domain in terms of polynomial matrix description(PMD).For a controllable first-order linear state-space system model,by using the right coprime factorization of its transfer function matrix,under the condition that the denominator matrix in the right coprime factorization is column reduced,it is equivalently transformed into a fully actuated PMD model,whose time-domain expression is just a high-order fully actuated(HOFA)system model.This method is a supplement to the previous one in the time-domain,and reveals a connection between the controllability of the first-order linear state-space system model and the fullactuation of its PMD model.Both continuous-time and discrete-time linear systems are considered.Some numerical examples are worked out to illustrate the effectiveness of the proposed approaches.展开更多
基金supported by National Natural Science Foundation of China(Nos.20775070, J0830413)Zhejiang Provincial Natural Science Foundation of China(Nos.R4080124,Y4090104,Y4090078)Zhejiang Qianjiang Project of Science and Technology for Competent People(No.2008R10028)
文摘An ion chromatography(IC) system coupled with on-line column-switching technique was used to determine anions ofμg/g levels in organic chemicals of analytical reagent grade.A novel polystyrene-divinylbenzene-carbon nanotube(PS-DVB-CNT) stationary phase was utilized for matrix elimination.A calibration study was conducted by preparing and analyzing eight concentrations(between 10 and 5000μg/L) of eight standards in deionized water.The linearity was between 0.9978 and 1.And the detection limits ranged from 1.54μg/L to 10.02μg/L.A spiking study was performed on two representative organic chemicals.The recoveries were between 84.3%and 119.6%.
基金the Science Center Program of the National Natural Science Foundation of China under Grant No.62188101the Major Program of National Natural Science Foundation of China under Grant Nos.61690210 and 61690212+1 种基金the National Natural Science Foundation of China under Grant No.61333003the Self-Planned Task of State Key Laboratory of Robotics and System(HIT)under Grant No.SKLRS201716A。
文摘This note studies fully actuated linear systems in the frequency domain in terms of polynomial matrix description(PMD).For a controllable first-order linear state-space system model,by using the right coprime factorization of its transfer function matrix,under the condition that the denominator matrix in the right coprime factorization is column reduced,it is equivalently transformed into a fully actuated PMD model,whose time-domain expression is just a high-order fully actuated(HOFA)system model.This method is a supplement to the previous one in the time-domain,and reveals a connection between the controllability of the first-order linear state-space system model and the fullactuation of its PMD model.Both continuous-time and discrete-time linear systems are considered.Some numerical examples are worked out to illustrate the effectiveness of the proposed approaches.