By taking equivalent thermal resistance, which reflects the average heat conduc- tion effect and is defined based on entransy dissipation, as optimization objective, the "volume to point" constructal problem...By taking equivalent thermal resistance, which reflects the average heat conduc- tion effect and is defined based on entransy dissipation, as optimization objective, the "volume to point" constructal problem of how to discharge the heat generated in a fixed volume to a heat sink on the border through relatively high conductive link is re-analyzed and re-optimized in this paper. The constructal shape of the control volume with the best average heat conduction effect is deduced. For the elemental area and the first order construct assembly, when the thermal current density in the high conductive link is linear with the length, the optimized shapes of assemble based on the minimization of entransy dissipation are the same as those based on minimization of maximum temperature difference, and the mean tem- perature difference is 2/3 of the maximum temperature difference. For the second and higher order construct assemblies, the thermal current densities in the high conductive link are not linear with the length, and the optimized shapes of assem- ble based on the minimization of entransy dissipation are different from those based on minimization of maximum temperature difference. For the same parame- ters, the constructs based on minimization of entransy dissipation and the con- structs based on minimization of maximum temperature difference are compared, and the results show that the constructs based on entransy dissipation can de- crease the mean temperature difference better than the constructs based on mini- mization of maximum temperature difference. But with the increase of the number of the order, the mean temperature difference does not always decrease, and there exist some fluctuations. Because the idea of entransy describes the heat transfer ability more suitably, all of the heat conduction constructal problems may be re-optimized based on it.展开更多
OBJECTIVE:This meta-analysis was performed to systematically assess the efficacy and safety of the Chinese herbal medicine Huangqi Guizhi Wuwu Decoction(HGWWD) for treating diabetic peripheral neuropathy.DATA SOUR...OBJECTIVE:This meta-analysis was performed to systematically assess the efficacy and safety of the Chinese herbal medicine Huangqi Guizhi Wuwu Decoction(HGWWD) for treating diabetic peripheral neuropathy.DATA SOURCES:Six electronic databases,including the Cochrane Library,MEDLINE database,Chinese Biomedical Database,Chinese National Knowledge Infrastructure Database,Chinese Science and Technique Journals Database,and the Wanfang Database,were search ed on the internet for randomized controlled trials published up until 1 December 2015.The search terms included "Chinese herbal medicine","diabetic peripheral neuropathy" and "randomized controlled trials" in Chinese and in English.DATA SELECTION:We included randomized controlled trials using HGWWD/modified HGWWD for the treatment group,without restriction for the control group.We assessed literature quality in accordance with the Cochrane Review Handbook.A random or a fixed effects model was used to analyze outcomes using Rev Man 5.2 software.OUTCOME MEASURES:The primary outcomes were changes in symptoms and nerve conduction velocities.The secondary outcomeswere fasting blood glucose and hemorheological indexes.RESULTS:Sixteen randomized controlled trials,with a total of 1,173 patients,were included.Meta-analysis revealed that the efficacy of HGWWD for diabetic peripheral neuropathy was significantly superior compared with the control treatment(i.e.,control group)(risk ratio = 0.36,95% confidence interval(CI):0.29–0.46,Z =8.33,P 〈 0.00001) Compared with the control group,there was an increase in median motor nerve conduction velocity(mean difference(MD) = 3.46,95%CI:1.88–5.04,Z = 4.30,P 〈 0.01) and median sensory nerve conduction velocity(MD = 3.30,95%CI:2.04–4.56,Z = 5.14,P 〈 0.01).There was also an increase in peroneal motor nerve conduction velocity(MD = 3.22,95%CI:2.45–3.98,Z = 8.21,P 〈 0.01) and peroneal sensory nerve conduction velocity(MD = 3.05,95%CI:2.01–4.09,Z = 5.75,P 〈 展开更多
Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of t...Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.展开更多
Using constructal entransy dissipation rate minimization method based on discrete variable cross-section conducting path,constructal optimizations of elemental area with variable cross-section conducting path are perf...Using constructal entransy dissipation rate minimization method based on discrete variable cross-section conducting path,constructal optimizations of elemental area with variable cross-section conducting path are performed,and the results are compared with the optimization results of elemental area with the constant cross-section conducting path.The comparison shows that the minimum mean temperature difference based on elemental area with variable cross-section conducting path increases and approaches a constant as the assembly's order increases,but the minimum mean temperature difference based on elemental area with constant cross-section conducting path decreases and approaches a constant as the assembly's order increases.The difference between them is caused by the different dimensionless mean temperature difference of the first order assembly.A universal constructal optimization method by self similar organization to improve heat transfer ability and its corresponding rule are proposed.With the constructal optimization method by self similar organization based on entransy dissipation rate minimization objective,the mean temperature difference approaches a constant as the assembly's order increases.展开更多
The analysis of the “tree-like network” construct method has been repeated. The high effective conduction channel distribution has been optimized again, without the premise that the new order assembly construct must...The analysis of the “tree-like network” construct method has been repeated. The high effective conduction channel distribution has been optimized again, without the premise that the new order assembly construct must be assembled by the optimized last order construct. It is proved that the “tree-like network” construct method is faultiness. A more optimal construct is obtained,; when the thermal conductivity; the proportion of the two heat conduction materials are constant, the limit of the minimum heat resistance is derived. All these conclusions can be used to guide the engineering application.展开更多
Major ozonated autohemotherapy is classically used in treating ischemic disorder of the lower limbs In the present study, we performed major ozonated autohemotherapy treatment in patients with acute cerebral infarctio...Major ozonated autohemotherapy is classically used in treating ischemic disorder of the lower limbs In the present study, we performed major ozonated autohemotherapy treatment in patients with acute cerebral infarction, and assessed outcomes according to the U.S. National Institutes of Health Stroke Score, Modified Rankin Scale, and transcranial magnetic stimulation motor-evoked potential. Compared with the control group, the clinical total effective rate and the cortical potential rise rate of the upper limbs were significantly higher, the central motor conduction time of upper limb was significantly shorter, and the upper limb motor-evoked potential amplitude was significantly increased, in the ozone group. In the ozone group, the National Institutes of Health Stroke Score was positively correlated with the central motor conduction time and the motor-evoked potential amplitude of the upper limb. Central motor conduction time and motor-evoked potential amplitude of the upper limb may be effective indicators of motor-evoked potentials to assess upper limb motor function in cerebral infarct patients. Furthermore, major ozonated autohemotherapy may promote motor function recovery of the upper limb in patients with acute cerebral infarction.展开更多
Background Hirayama disease is a rare disease characterized by juvenile-onset of asymmetric amyotrophy, of which etiology has not been clarified. The aim of our study was to investigate the clinical and neurophysiolog...Background Hirayama disease is a rare disease characterized by juvenile-onset of asymmetric amyotrophy, of which etiology has not been clarified. The aim of our study was to investigate the clinical and neurophysiologic characteristics of Hirayama disease. Methods Neurophysiological tests, including nerve conduction studies (NCS), F-wave and routine electromyography (EMG), were performed in seventy-three patients with Hirayama disease. EMG was selectively performed on upper and lower extremities, sternocleidomast and thoracic paravertebral muscles according to the clinical features of the patients. Results Abnormal NCS parameters, including decreased compound muscle action potentials or delayed distal motor latency, were found in 34.2% (25/73) and 12.3% (9/73) of the patients, respectively. A total of 24.6% (18/73) of the patients showed decreased F-wave frequency. EMG demonstrated the presence of neurogenic lesions in all patients with spontaneous potentials, prolonged duration or augmentation of amplitude in motor unit potentials (MUPs), or a single pattern of MUP recruitment. About 17.8% (13/73) of the patients showed neurogenic lesions, mostly in the C7-8 level of the cervical cord, only in the upper extremity of affected side, whereas 35.6% (26/73) of the patients possessed lesions in the upper extremities bilaterally. A total of 46.6% (34/73) of patients exhibited abnormalities in the lower extremities, sterno- cleidomast or thoracic paravertebral muscle. Changes in motor NCS were significantly correlated with muscle strength. Conclusions EMG detects diffused subclinical neurogenic lesion in a high proportion of patients with Hirayama disease. Results of our study challenge the hypothesis that Hirayama disease is a type of cervical myelopathy.展开更多
OBJECTIVE: To evaluate the efficacy of α-lipoic acid(ALA) plus epalrestat combination therapy in the treatment of diabetic peripheral neuropathy(DPN). DATA SOURCES: The electronic databases of Pub Med, Medline,...OBJECTIVE: To evaluate the efficacy of α-lipoic acid(ALA) plus epalrestat combination therapy in the treatment of diabetic peripheral neuropathy(DPN). DATA SOURCES: The electronic databases of Pub Med, Medline, Embase, the Cochrane Library, the Chinese National Knowledge Infrastructure, the Wanfang Database and the Chinese Biomedical Database were used to retrieve relevant studies without language restrictions. The search was conducted from the inception of each database to 7 October 2016. The key terms were(diabetic peripheral neuropathy or diabetic neuropathy or DPN) AND(α-lipoic acid or lipoic acid or thioctic acid) AND epalrestat. DATA SELECTION: All of the eligible studies met the following inclusion criteria:(1) Randomized controlled trials that compared efficacy and safety of epalrestat plus ALA combination therapy versus epalrestat or ALA monotherapy in patients with DPN.(2) The minimum duration of treatment was 2 weeks.(3) The DPN patients were diagnosed using the World Health Organization standardized type 2 diabetes mellitus and DPN criteria.(4) Studies contained at least one measure that could reflect the efficacy of the drug and nerve conduction velocities. Studies in which the control group used epalrestat or ALA combined with other drugs were excluded. Statistical analyses were performed using STATA software for meta-analysis. OUTCOME MEASURES: The primary outcomes were the therapeutic efficacy, median motor nerve conduction velocity(MNCV), median sensory nerve conduction velocity(SNCV), peroneal MNCV and peroneal SNCV.RESULTS: Twenty studies with 1894 DPN patients were included, including 864 patients in the ALA plus epalrestat group, 473 in the ALA group and 557 in the epalrestat group. The efficacy of ALA plus epalrestat combination therapy was superior to ALA and epalrestat monotherapies(RR = 1.29, 95% CI: 1.21–1.38; RR = 1.43, 95% CI: 1.34–1.54, respectively). ALA plus epalrestat combination therapy also significantly improved m展开更多
The mathematical model of the three-dimensional semiconductor devices of heat conduction is described by a system of four quasilinear partial differential equations for initial boundary value problem. One equation in ...The mathematical model of the three-dimensional semiconductor devices of heat conduction is described by a system of four quasilinear partial differential equations for initial boundary value problem. One equation in elliptic form is for the electric potential; two equations of convection-dominated diffusion type are for the electron and hole concentration; and one heat conduction equation is for temperature. Characteristic finite difference schemes for two kinds of boundary value problems are put forward. By using the thick and thin grids to form a complete set and treating the product threefold-quadratic interpolation, variable time step method with the boundary condition, calculus of variations and the theory of prior estimates and techniques, the optimal error estimates in L2 norm are derived in the approximate solutions.展开更多
Rapid development of energy,electrical and electronic technologies has put forward higher requirements for the thermal conductivities of polymers and their composites.However,the thermal conductivity coefficient(λ)va...Rapid development of energy,electrical and electronic technologies has put forward higher requirements for the thermal conductivities of polymers and their composites.However,the thermal conductivity coefficient(λ)values of prepared thermally conductive polymer composites are still difficult to achieve expectations,which has become the bottleneck in the fields of thermally conductive polymer composites.Aimed at that,based on the accumulation of the previous research works by related researchers and our research group,this paper proposes three possible directions for breaking through the bottlenecks:(1)preparing and synthesizing intrinsically thermally conductive polymers,(2)reducing the interfacial thermal resistance in thermally conductive polymer composites,and(3)establishing suitable thermal conduction models and studying inner thermal conduction mechanism to guide experimental optimization.Also,the future development trends of the three above-mentioned directions are foreseen,hoping to provide certain basis and guidance for the preparation,researches and development of thermally conductive polymers and their composites.展开更多
With the improved moving least-squares (IMLS) approximation, an orthogonal function system with a weight function is used as the basis function. The combination of the element-free Galerkin (EFG) method and the IMLS a...With the improved moving least-squares (IMLS) approximation, an orthogonal function system with a weight function is used as the basis function. The combination of the element-free Galerkin (EFG) method and the IMLS approximation leads to the development of the improved element-free Galerkin (IEFG) method. In this paper, the IEFG method is applied to study the partial differential equations that control the heat flow in three-dimensional space. With the IEFG technique, the Galerkin weak form is employed to develop the discretized system equations, and the penalty method is applied to impose the essential boundary conditions. The traditional difference method for two-point boundary value problems is selected for the time discretization. As the transient heat conduction equations and the boundary and initial conditions are time dependent, the scaling parameter, number of nodes and time step length are considered in a convergence study.展开更多
Rapid industrialization has accordingly increased the demand for energy.This has resulted in the increasingly severe energy and environmental crises.Hydrogen production,based on the photocatalytic water splitting driv...Rapid industrialization has accordingly increased the demand for energy.This has resulted in the increasingly severe energy and environmental crises.Hydrogen production,based on the photocatalytic water splitting driven by sunlight,is able to directly convert solar energy into a usable or storable energy resource,which is considered to be an ideal alternative energy source to assist in solving the energy crisis and environmental pollution.Unfortunately,the hydrogen production efficiency of single phase photocatalysts is too low to meet the practical requirements.The construction of heterostructured photocatalyst systems,which are comprised of multiple components or multiple phases,is an efficient method to facilitate the separation of electron‐hole pairs to minimize the energy‐waste,provide more electrons,enhance their redox ability,and hence improve the photocatalytic activity.We summarize the recent progress in the rational design and fabrication of nanoheterostructured photocatalysts.The heterojunction photocatalytic hydrogen generation systems can be divided into type‐I,type‐II,pn‐junction and Z‐scheme junction,according to the differences in the transfer of the photogenerated electrons and holes.Finally,a summary and some of the challenges and prospects for the future development of heterojunction photocatalytic systems are discussed.展开更多
Based on constructal theory,the constructs of three "volume-point" heat conduction models with three-dimensional cylindrical element and rectangular and triangular elements on microscale and nanoscale are op...Based on constructal theory,the constructs of three "volume-point" heat conduction models with three-dimensional cylindrical element and rectangular and triangular elements on microscale and nanoscale are optimized by taking minimum entransy dissipation rate as optimization objective.The optimal constructs of the three "volume-point" heat conduction models with minimum dimensionless equivalent thermal resistance are obtained.The results show that the optimal constructs of the three-dimensional cylindrical assembly based on the minimizations of dimensionless equivalent thermal resistance and dimensionless maximum thermal resistance are different,which is obviously different from the comparison between those of the corresponding two-dimensional rectangular assembly based on the minimizations of these two objectives.The optimal constructs based on rectangular and triangular elements on microscale and nanoscale when the size effect takes effect are obviously different from those when the size effect does not take effect.Because the thermal current density in the high conductivity channel of the rectangular and triangular second order assemblies are not linear with the length,the optimal constructs of these assemblies based on the minimization of entransy dissipation rate are different from those based on the minimization of maximum temperature difference.The dimensionless equivalent thermal resistance defined based on entransy dissipation rate reflects the average heat transfer performance of the construct.The studies on "volume-point" heat conduction constructal problems at three-dimensional conditions and microscale and nanoscale by taking minimum entransy dissipation rate as optimization objective extend the application range of the entransy dissipation extremum principle.展开更多
基金Supported by the Program for New Century Excellent Talents in University of Chinathe Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No. 200136)
文摘By taking equivalent thermal resistance, which reflects the average heat conduc- tion effect and is defined based on entransy dissipation, as optimization objective, the "volume to point" constructal problem of how to discharge the heat generated in a fixed volume to a heat sink on the border through relatively high conductive link is re-analyzed and re-optimized in this paper. The constructal shape of the control volume with the best average heat conduction effect is deduced. For the elemental area and the first order construct assembly, when the thermal current density in the high conductive link is linear with the length, the optimized shapes of assemble based on the minimization of entransy dissipation are the same as those based on minimization of maximum temperature difference, and the mean tem- perature difference is 2/3 of the maximum temperature difference. For the second and higher order construct assemblies, the thermal current densities in the high conductive link are not linear with the length, and the optimized shapes of assem- ble based on the minimization of entransy dissipation are different from those based on minimization of maximum temperature difference. For the same parame- ters, the constructs based on minimization of entransy dissipation and the con- structs based on minimization of maximum temperature difference are compared, and the results show that the constructs based on entransy dissipation can de- crease the mean temperature difference better than the constructs based on mini- mization of maximum temperature difference. But with the increase of the number of the order, the mean temperature difference does not always decrease, and there exist some fluctuations. Because the idea of entransy describes the heat transfer ability more suitably, all of the heat conduction constructal problems may be re-optimized based on it.
基金supported by a grant from the National Basic Research Program of China(973 Program),No.2010CB530600Institutes Project from Guang’anmen Hospital of China Academy of Chinese Medical Sciences,No.2011261
文摘OBJECTIVE:This meta-analysis was performed to systematically assess the efficacy and safety of the Chinese herbal medicine Huangqi Guizhi Wuwu Decoction(HGWWD) for treating diabetic peripheral neuropathy.DATA SOURCES:Six electronic databases,including the Cochrane Library,MEDLINE database,Chinese Biomedical Database,Chinese National Knowledge Infrastructure Database,Chinese Science and Technique Journals Database,and the Wanfang Database,were search ed on the internet for randomized controlled trials published up until 1 December 2015.The search terms included "Chinese herbal medicine","diabetic peripheral neuropathy" and "randomized controlled trials" in Chinese and in English.DATA SELECTION:We included randomized controlled trials using HGWWD/modified HGWWD for the treatment group,without restriction for the control group.We assessed literature quality in accordance with the Cochrane Review Handbook.A random or a fixed effects model was used to analyze outcomes using Rev Man 5.2 software.OUTCOME MEASURES:The primary outcomes were changes in symptoms and nerve conduction velocities.The secondary outcomeswere fasting blood glucose and hemorheological indexes.RESULTS:Sixteen randomized controlled trials,with a total of 1,173 patients,were included.Meta-analysis revealed that the efficacy of HGWWD for diabetic peripheral neuropathy was significantly superior compared with the control treatment(i.e.,control group)(risk ratio = 0.36,95% confidence interval(CI):0.29–0.46,Z =8.33,P 〈 0.00001) Compared with the control group,there was an increase in median motor nerve conduction velocity(mean difference(MD) = 3.46,95%CI:1.88–5.04,Z = 4.30,P 〈 0.01) and median sensory nerve conduction velocity(MD = 3.30,95%CI:2.04–4.56,Z = 5.14,P 〈 0.01).There was also an increase in peroneal motor nerve conduction velocity(MD = 3.22,95%CI:2.45–3.98,Z = 8.21,P 〈 0.01) and peroneal sensory nerve conduction velocity(MD = 3.05,95%CI:2.01–4.09,Z = 5.75,P 〈
文摘Taking the fluid temperature distribution along the borehole depth into account, a new quasi-three-dimensional model for vertical ground heat exchangers has been established, which provides a better understanding of the heat transfer processes in the geothermal heat exchangers. On this basis the efficiency of the borehole has been defined and its analytical expression derived. Comparison with the previous two-dimensional model shows that the quasi-three-dimensional model is more rational and more accurate to depict the practical feature of the conduction of geothermal heat exchanger, and the efficiency notion can be easily used to determine the inlet and outlet temperature of the circulating fluid inside the heat exchanger.
基金supported by Program for New Century Excellent Talents in Universities of China and the Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No. 200136)
文摘Using constructal entransy dissipation rate minimization method based on discrete variable cross-section conducting path,constructal optimizations of elemental area with variable cross-section conducting path are performed,and the results are compared with the optimization results of elemental area with the constant cross-section conducting path.The comparison shows that the minimum mean temperature difference based on elemental area with variable cross-section conducting path increases and approaches a constant as the assembly's order increases,but the minimum mean temperature difference based on elemental area with constant cross-section conducting path decreases and approaches a constant as the assembly's order increases.The difference between them is caused by the different dimensionless mean temperature difference of the first order assembly.A universal constructal optimization method by self similar organization to improve heat transfer ability and its corresponding rule are proposed.With the constructal optimization method by self similar organization based on entransy dissipation rate minimization objective,the mean temperature difference approaches a constant as the assembly's order increases.
文摘The analysis of the “tree-like network” construct method has been repeated. The high effective conduction channel distribution has been optimized again, without the premise that the new order assembly construct must be assembled by the optimized last order construct. It is proved that the “tree-like network” construct method is faultiness. A more optimal construct is obtained,; when the thermal conductivity; the proportion of the two heat conduction materials are constant, the limit of the minimum heat resistance is derived. All these conclusions can be used to guide the engineering application.
基金supported by the Guangdong Province Medical Science Research Fund, No. B200258
文摘Major ozonated autohemotherapy is classically used in treating ischemic disorder of the lower limbs In the present study, we performed major ozonated autohemotherapy treatment in patients with acute cerebral infarction, and assessed outcomes according to the U.S. National Institutes of Health Stroke Score, Modified Rankin Scale, and transcranial magnetic stimulation motor-evoked potential. Compared with the control group, the clinical total effective rate and the cortical potential rise rate of the upper limbs were significantly higher, the central motor conduction time of upper limb was significantly shorter, and the upper limb motor-evoked potential amplitude was significantly increased, in the ozone group. In the ozone group, the National Institutes of Health Stroke Score was positively correlated with the central motor conduction time and the motor-evoked potential amplitude of the upper limb. Central motor conduction time and motor-evoked potential amplitude of the upper limb may be effective indicators of motor-evoked potentials to assess upper limb motor function in cerebral infarct patients. Furthermore, major ozonated autohemotherapy may promote motor function recovery of the upper limb in patients with acute cerebral infarction.
文摘Background Hirayama disease is a rare disease characterized by juvenile-onset of asymmetric amyotrophy, of which etiology has not been clarified. The aim of our study was to investigate the clinical and neurophysiologic characteristics of Hirayama disease. Methods Neurophysiological tests, including nerve conduction studies (NCS), F-wave and routine electromyography (EMG), were performed in seventy-three patients with Hirayama disease. EMG was selectively performed on upper and lower extremities, sternocleidomast and thoracic paravertebral muscles according to the clinical features of the patients. Results Abnormal NCS parameters, including decreased compound muscle action potentials or delayed distal motor latency, were found in 34.2% (25/73) and 12.3% (9/73) of the patients, respectively. A total of 24.6% (18/73) of the patients showed decreased F-wave frequency. EMG demonstrated the presence of neurogenic lesions in all patients with spontaneous potentials, prolonged duration or augmentation of amplitude in motor unit potentials (MUPs), or a single pattern of MUP recruitment. About 17.8% (13/73) of the patients showed neurogenic lesions, mostly in the C7-8 level of the cervical cord, only in the upper extremity of affected side, whereas 35.6% (26/73) of the patients possessed lesions in the upper extremities bilaterally. A total of 46.6% (34/73) of patients exhibited abnormalities in the lower extremities, sterno- cleidomast or thoracic paravertebral muscle. Changes in motor NCS were significantly correlated with muscle strength. Conclusions EMG detects diffused subclinical neurogenic lesion in a high proportion of patients with Hirayama disease. Results of our study challenge the hypothesis that Hirayama disease is a type of cervical myelopathy.
基金supported by the National Natural Science Foundation of China,No.81370165a grant from the Public Benefit Technology and Society Development Program of Zhejiang Province of China,No.2015C33309+2 种基金a grant from the Ningbo Science and Technology Innovation Team Program in China,No.2014B82002,2015B11050a grant from the Ningbo Science and Technology Project in China,No.2015A610217the Fang Runhua Fund of Hong Kong,K.C.Wong Magna Fund in Ningbo University
文摘OBJECTIVE: To evaluate the efficacy of α-lipoic acid(ALA) plus epalrestat combination therapy in the treatment of diabetic peripheral neuropathy(DPN). DATA SOURCES: The electronic databases of Pub Med, Medline, Embase, the Cochrane Library, the Chinese National Knowledge Infrastructure, the Wanfang Database and the Chinese Biomedical Database were used to retrieve relevant studies without language restrictions. The search was conducted from the inception of each database to 7 October 2016. The key terms were(diabetic peripheral neuropathy or diabetic neuropathy or DPN) AND(α-lipoic acid or lipoic acid or thioctic acid) AND epalrestat. DATA SELECTION: All of the eligible studies met the following inclusion criteria:(1) Randomized controlled trials that compared efficacy and safety of epalrestat plus ALA combination therapy versus epalrestat or ALA monotherapy in patients with DPN.(2) The minimum duration of treatment was 2 weeks.(3) The DPN patients were diagnosed using the World Health Organization standardized type 2 diabetes mellitus and DPN criteria.(4) Studies contained at least one measure that could reflect the efficacy of the drug and nerve conduction velocities. Studies in which the control group used epalrestat or ALA combined with other drugs were excluded. Statistical analyses were performed using STATA software for meta-analysis. OUTCOME MEASURES: The primary outcomes were the therapeutic efficacy, median motor nerve conduction velocity(MNCV), median sensory nerve conduction velocity(SNCV), peroneal MNCV and peroneal SNCV.RESULTS: Twenty studies with 1894 DPN patients were included, including 864 patients in the ALA plus epalrestat group, 473 in the ALA group and 557 in the epalrestat group. The efficacy of ALA plus epalrestat combination therapy was superior to ALA and epalrestat monotherapies(RR = 1.29, 95% CI: 1.21–1.38; RR = 1.43, 95% CI: 1.34–1.54, respectively). ALA plus epalrestat combination therapy also significantly improved m
基金Project supported by the National Scaling Program,the National Eighth-Five Year Tackling Key Problems Program and the Doctoral Found of the National Education Commission.
文摘The mathematical model of the three-dimensional semiconductor devices of heat conduction is described by a system of four quasilinear partial differential equations for initial boundary value problem. One equation in elliptic form is for the electric potential; two equations of convection-dominated diffusion type are for the electron and hole concentration; and one heat conduction equation is for temperature. Characteristic finite difference schemes for two kinds of boundary value problems are put forward. By using the thick and thin grids to form a complete set and treating the product threefold-quadratic interpolation, variable time step method with the boundary condition, calculus of variations and the theory of prior estimates and techniques, the optimal error estimates in L2 norm are derived in the approximate solutions.
基金National Natural Science Foundation of China(51773169 and 51973173)Guangdong Basic and Applied Basic Research Foundation(2019B1515120093)+2 种基金Technological Base Scientific Research ProjectsNatural Science Basic Research Plan for Distinguished Young Scholars in Shaanxi Province(2019JC-11)Polymer Electromagnetic Functional Materials Innovation Team of Shaanxi Sanqin Scholars.
文摘Rapid development of energy,electrical and electronic technologies has put forward higher requirements for the thermal conductivities of polymers and their composites.However,the thermal conductivity coefficient(λ)values of prepared thermally conductive polymer composites are still difficult to achieve expectations,which has become the bottleneck in the fields of thermally conductive polymer composites.Aimed at that,based on the accumulation of the previous research works by related researchers and our research group,this paper proposes three possible directions for breaking through the bottlenecks:(1)preparing and synthesizing intrinsically thermally conductive polymers,(2)reducing the interfacial thermal resistance in thermally conductive polymer composites,and(3)establishing suitable thermal conduction models and studying inner thermal conduction mechanism to guide experimental optimization.Also,the future development trends of the three above-mentioned directions are foreseen,hoping to provide certain basis and guidance for the preparation,researches and development of thermally conductive polymers and their composites.
基金the National Natural Science Foundation of China (Grant No. 11171208)Shanghai Leading Academic Discipline Project (Grant No. S30106)
文摘With the improved moving least-squares (IMLS) approximation, an orthogonal function system with a weight function is used as the basis function. The combination of the element-free Galerkin (EFG) method and the IMLS approximation leads to the development of the improved element-free Galerkin (IEFG) method. In this paper, the IEFG method is applied to study the partial differential equations that control the heat flow in three-dimensional space. With the IEFG technique, the Galerkin weak form is employed to develop the discretized system equations, and the penalty method is applied to impose the essential boundary conditions. The traditional difference method for two-point boundary value problems is selected for the time discretization. As the transient heat conduction equations and the boundary and initial conditions are time dependent, the scaling parameter, number of nodes and time step length are considered in a convergence study.
基金supported by the National Natural Science Foundation of China (51572253,21271165)Scientific Research Grant of Hefei Science Center of CAS (2015SRG-HSC048)Cooperation between NSFC and Netherlands Organization for Scientific Research (51561135011)~~
文摘Rapid industrialization has accordingly increased the demand for energy.This has resulted in the increasingly severe energy and environmental crises.Hydrogen production,based on the photocatalytic water splitting driven by sunlight,is able to directly convert solar energy into a usable or storable energy resource,which is considered to be an ideal alternative energy source to assist in solving the energy crisis and environmental pollution.Unfortunately,the hydrogen production efficiency of single phase photocatalysts is too low to meet the practical requirements.The construction of heterostructured photocatalyst systems,which are comprised of multiple components or multiple phases,is an efficient method to facilitate the separation of electron‐hole pairs to minimize the energy‐waste,provide more electrons,enhance their redox ability,and hence improve the photocatalytic activity.We summarize the recent progress in the rational design and fabrication of nanoheterostructured photocatalysts.The heterojunction photocatalytic hydrogen generation systems can be divided into type‐I,type‐II,pn‐junction and Z‐scheme junction,according to the differences in the transfer of the photogenerated electrons and holes.Finally,a summary and some of the challenges and prospects for the future development of heterojunction photocatalytic systems are discussed.
基金supported by the National Natural Science Foundation of China (Grant No. 51176203)the Natural Science Foundation of Naval University of Engineering (Grant No. HGDYDJJ10011)the Natural Science Foundation for Youngsters of Naval University of Engineering (Grant No. HGDQNJJ10017)
文摘Based on constructal theory,the constructs of three "volume-point" heat conduction models with three-dimensional cylindrical element and rectangular and triangular elements on microscale and nanoscale are optimized by taking minimum entransy dissipation rate as optimization objective.The optimal constructs of the three "volume-point" heat conduction models with minimum dimensionless equivalent thermal resistance are obtained.The results show that the optimal constructs of the three-dimensional cylindrical assembly based on the minimizations of dimensionless equivalent thermal resistance and dimensionless maximum thermal resistance are different,which is obviously different from the comparison between those of the corresponding two-dimensional rectangular assembly based on the minimizations of these two objectives.The optimal constructs based on rectangular and triangular elements on microscale and nanoscale when the size effect takes effect are obviously different from those when the size effect does not take effect.Because the thermal current density in the high conductivity channel of the rectangular and triangular second order assemblies are not linear with the length,the optimal constructs of these assemblies based on the minimization of entransy dissipation rate are different from those based on the minimization of maximum temperature difference.The dimensionless equivalent thermal resistance defined based on entransy dissipation rate reflects the average heat transfer performance of the construct.The studies on "volume-point" heat conduction constructal problems at three-dimensional conditions and microscale and nanoscale by taking minimum entransy dissipation rate as optimization objective extend the application range of the entransy dissipation extremum principle.