超声心动图联合呼气末CO2分压监测预防宫腔镜术中空气栓塞的临床研究 被引量:13
1
作者 许运巧 张菊新 《中华妇产科杂志》 CAS CSCD 北大核心 2013年第11期828-832,共5页
目的 探讨经胸廓超声心动图(TTE)联合呼气末CO2分压(PETCO2)监测预防宫腔镜术中空气栓塞的价值.方法 2010年8月至2012年8月,在河南省人民医院接受全身麻醉下宫腔镜手术的患者300例,在术中行TTE联合PETCO2监测,观察并详细记录右心房... 目的 探讨经胸廓超声心动图(TTE)联合呼气末CO2分压(PETCO2)监测预防宫腔镜术中空气栓塞的价值.方法 2010年8月至2012年8月,在河南省人民医院接受全身麻醉下宫腔镜手术的患者300例,在术中行TTE联合PETCO2监测,观察并详细记录右心房出现气栓的时间、空气栓塞分级(0~4级)、PETCO2、血氧饱和度、血压、液体负差值、术中出血量等.对空气栓塞分级≥3级,PETCO2下降≥5 mm Hg(1 mm Hg=0.133 kPa)的24例(干预组)患者给予立即停止手术、左侧卧位并抬高右肩、吸氧、地塞米松10 mg静脉滴注等;对空气栓塞分级≥3级,PETCO2下降<5 mm Hg的5例(对照组)患者给予立即停止手术,严密观察病情变化.比较两组患者PETCO2继续下降例数、PETCO2恢复时间.结果 (1)空气栓塞发生情况:300例宫腔镜手术者中共有34例发生空气栓塞.发生空气栓塞的患者TTE均可在下腔静脉、右心房、右心室探及气栓信号,29例患者右心房有连续性的成群气栓通过,32例患者PETCO2下降>2 mm Hg,14例患者血氧饱和度<95%,4例患者血压下降≥20%.(2)PETCO2下降程度与空气栓塞分级变化:PETCO2下降程度与空气栓塞分级呈正相关(r=0.601,P<0.01),PET CO2下降≥5 mm Hg时,右心房均有连续性成群气栓通过,PETCO2下降≥10 mm Hg的8例中,7例患者空气栓塞分级为4级.空气栓塞分级为3级与4级者,PETCO2下降程度[分别为(7.5 ±2.4) mm Hg、(11.1±4.1)mm Hg]、液体负差值[分别为(688±150) ml、(925±268) ml]、术中出血量[分别为(71±36) ml、(127±56) ml]比较,差异均有统计学意义(P<0.05).(3) PETCO2继续下降例数及恢复时间:干预组与对照组患者PETCO2继续下降分别为2、4例,PETCO2恢复时间分别为(4.8±1.6)、(8.3±1.9) min,两组比较,差异均有统计学意义(P<0.05).结论 TTE联合PETCO2监测能有效预测宫腔镜术中空气栓塞的发生;右� 展开更多
关键词 栓塞 空气 超声心动描记术 二氧化碳捕记术 宫腔镜检查
原文传递
急危重症呼末二氧化碳监测的应用 被引量:8
2
作者 江学成 《世界急危重病医学杂志》 2007年第6期2145-2151,共7页
呼末二氧化碳分乐(PetCO2)测量是无创性的,可连续观察,动态显示,趋势回顾以及图波记录。本文着重介绍PetCO2监测在评价肺通气和循环灌注(尤其在心肺复苏)、辅助气管插管、诊断呼吸道疾病或事件等方面有极其重要的价值。
关键词 呼末二氧化碳分压 病理生理 肺通气 CO2波形
下载PDF
呼出气二氧化碳监测仪的研究进展及其在非气管插管患者中的应用 被引量:6
3
作者 张小青 李民 《中国微创外科杂志》 CSCD 北大核心 2016年第11期1041-1043,1052,共4页
肺泡通气不足和呼吸抑制常见于接受镇静药物或阿片类药物的患者。目前的临床指南均推荐将无创的呼出气二氧化碳监测仪作为有呼吸抑制风险的非插管患者的常规监测方法。本文对呼出气二氧化碳监测仪对非插管患者进行监测的临床研究进行文... 肺泡通气不足和呼吸抑制常见于接受镇静药物或阿片类药物的患者。目前的临床指南均推荐将无创的呼出气二氧化碳监测仪作为有呼吸抑制风险的非插管患者的常规监测方法。本文对呼出气二氧化碳监测仪对非插管患者进行监测的临床研究进行文献综述,其在保障患者安全、及时发现呼吸抑制方面发挥重要作用,对存在呼吸抑制风险的患者,不应单纯依赖脉搏氧饱和度。 展开更多
关键词 呼出气二氧化碳监测仪 呼气末二氧化碳分压
下载PDF
Comparison of the pulmonary dead-space fraction derived from ventilator volumetric capnography and a validated equation in the survival prediction of patients with acute respiratory distress syndrome 被引量:6
4
作者 Yu-Jiao Zhang xin-Jing Gao +5 位作者 Zhi-Bo Li Zhi-Yong Wang Quan-Sheng Feng Cheng-Fen Yin Xing Lu Lei Xu 《Chinese Journal of Traumatology》 CAS CSCD 2016年第3期141-145,共5页
Purpose: This prospective observational study aims to evaluate the accuracy of dead-space fraction derived from the ventilator volumetric capnography (volumetric CO2) or a prediction equation to predict the surviva... Purpose: This prospective observational study aims to evaluate the accuracy of dead-space fraction derived from the ventilator volumetric capnography (volumetric CO2) or a prediction equation to predict the survival of mechanically ventilated patients with acute respiratory distress syndrome (ARDS). Methods: Consecutive VDJVT measurements were obtained based upon a prediction equation validated by Frankenfield et al for dead-space ventilation fraction: VD/VT = 0.320 + 0.0106 (PaCO2-ETCO2) 4- 0.003 (RR) + 0.0015 (age) in adult patients who had infection-related severe pneumonia and were confirmed as having ARDS. Here PaCO2 is the arterial partial pressure of carbon dioxide in mmHg; ETC02, the end- tidal carbon dioxide measurement in mmHg; RR, respiratory rate per minute; and age in years. Once the patient had intubation, positive end expiratory pressure was adjusted and after Phigh reached a steady state, VD/VT was measured and recorded as the data for the first day. VD/VT measurement was repeated on days 2, 3, 4, 5 and 6. Meanwhile we collected dead-space fraction directly from the ventilator volu- metric CO2 and recorded it as Vd/Vt. We analyzed the changes in VD/VT and Vd/Vt over the f-day period to determine their accuracy in predicting the survival of ARDS patients. Results: Overall, 46 patients with ARD5 met the inclusion criteria and 24 of them died, During the first 6 days of intubation, VD/VT was significantly higher in nonsurvivors on day 4 (0.70 ± 0,01 vs 0.57 ± 0.01 ), day 5 (0.73 ± 0.01 vs, 0.54 ± 0.01 ), and day 6 (0.73 ±0,02 vs. 0.54 ± 0.01 ) (all p - 0.000). Vd/Vt showed no significant difference on days 1-4 but it was much higher in nonsurvivors on day 5 (0.45 ± 0.04 vs. 0.41 ±0.06) and day 6 (0.47 ± 0,05 vs. 0.40 ± 0.03) (both p - 0.008). VD/VT on the fourth day was more accurate to predict survival than Vd/Vt. The area under the receiver-operating characteristic curve for VD/VT and Vd/Vt in evaluating ARDS patients survival wa 展开更多
关键词 Respiratory distress syndrome adultRespiration artificialPulmonary dead-space fractionSurvivalVolumetric capnography
原文传递
神经外科重症监护病房患者呼气末与动脉血二氧化碳分压的相关性 被引量:4
5
作者 王磊 雷晋 +3 位作者 冯军峰 毛青 高国一 江基尧 《中华创伤杂志》 CAS CSCD 北大核心 2015年第9期814-819,共6页
目的分析神经外科重症监护病房(NICU)患者呼气末二氧化碳分压(PetCO2)与动脉血二氧化碳分压(PaCO2)的相关性及其影响因素,探讨PetCO2的临床实用价值。方法选取32例NICU行气管插管或气管切开的患者,其中脑外伤16例,自发性脑出血... 目的分析神经外科重症监护病房(NICU)患者呼气末二氧化碳分压(PetCO2)与动脉血二氧化碳分压(PaCO2)的相关性及其影响因素,探讨PetCO2的临床实用价值。方法选取32例NICU行气管插管或气管切开的患者,其中脑外伤16例,自发性脑出血9例,大面积脑梗死4例,大脑前交通动脉瘤2例,前颅窝底动静脉畸形1例。格拉斯哥昏迷评分(GCS)≤10分。每日早晨7时行动脉血气分析并将PaCO2与同步测定的PetCO2进行比较,根据PaCO2与PetCO2的差值[P(a—et)C02]将患者分为P(a—et)C02高值组[P(a—et)CO2〉5mmHg]和P(a—et)C02正常组[-5mmHg≤P(a—et)C02≤5mmHg],观察PaC02与PetC02动态相关性及两组GCS、血压(BP)、心率(HR)、呼吸频率(RR)、体温(BT)、氧饱和度(SpO:)等参数的关系。结果对32例患者129次同步血气样本分析结果表明,PaCO2与PetCO2均呈正态分布(r=0.668,P〈0.01);根据Bland—Altman绘图得出69.8%的P(a—et)C02值处于-4-5mmHg范围内。P(a—et)C02高值组比P(a—et)CO2正常组具有较低的初始GCS、即时GCS、BT、pH及较高的实际碳酸氢盐(AB)、PaCO2。呼气末正压通气(PEEP)〉5mmH20时两者相关性快速降低(r=0.229,P〈0.01)。结论NICU患者的PaCO2与PetCO2具有较好的相关性,可以用来进行连续呼吸功能监测。初始GCS、BT、AB及PEEP可以对两者的相关性产生影响,因此用PetCO2评估患者通气状况时需考虑以匕因素。 展开更多
关键词 颅脑损伤 二氧化碳描记术 血气监测 经皮 通气机 机械
原文传递
全身麻醉患者拔除气管导管后微旁流P_(ET)CO_(2)与PaCO_(2)的相关性
6
作者 王玥 辜晓岚 +1 位作者 王丽君 顾连兵 《中国临床研究》 CAS 2024年第8期1210-1213,共4页
目的 探讨全身麻醉患者拔除气管导管后微旁流呼气末二氧化碳分压(P_(ET)CO_(2))与动脉血二氧化碳分压(PaCO_(2))的相关性。方法 选择江苏省肿瘤医院2021年1月至5月择期行腹部手术的患者120例,采取随机数字表法将患者分为3组,每组40例,... 目的 探讨全身麻醉患者拔除气管导管后微旁流呼气末二氧化碳分压(P_(ET)CO_(2))与动脉血二氧化碳分压(PaCO_(2))的相关性。方法 选择江苏省肿瘤医院2021年1月至5月择期行腹部手术的患者120例,采取随机数字表法将患者分为3组,每组40例,分别经鼻导管不同流量吸氧,低流量组(L组)2 L/min,中流量组(M组)4 L/min和高流量组(H组)6 L/min。在拔除气管导管30 min时记录P_(ET)CO_(2)数值并抽取动脉血测量PaCO_(2),Pearson法分析P_(ET)CO_(2)与PaCO_(2)的相关性。结果 拔管30 min时,三组P_(ET)CO_(2)、PaCO_(2)、RR差异无统计学意义(P>0.05);L组PaO_(2)和SpO_(2)均显著低于M组和H组(P<0.05)。L组、M组、H组微旁流P_(ET)CO_(2)与PaCO_(2)均呈高度相关(r=0.931、0.878、0.838,P<0.01),二者的相关性随着氧流量的升高而降低。结论 PACU内全身麻醉患者拔除气管导管后使用微旁流P_(ET)CO_(2)监测时,在2~6 L/min的氧流量下微旁流P_(ET)CO_(2)与PaCO_(2)均保持高度相关性,可作为评估PaCO_(2)的重要参考。 展开更多
关键词 二氧化碳描记术 氧吸入疗法 肺通气 呼气末二氧化碳分压 动脉血二氧化碳分压
原文传递
End-tidal capnometry during emergency department procedural sedation and analgesia: a randomized, controlled study
7
作者 Samuel G. Campbell Kirk D. Magee +8 位作者 Peter J. Zed Patrick Froese Glenn Etsell Alan LaPierre Donna Warren Robert R. MacKinley Michael B. Butler George Kovacs David A. Petrie 《World Journal of Emergency Medicine》 CAS 2016年第1期13-18,共6页
BACKGROUND:This prospective,randomized trial was undertaken to evaluate the utility of adding end-tidal capnometry(ETC)to pulse oximetry(PO)in patients undergoing procedural sedation and analgesia(PSA)in the emergency... BACKGROUND:This prospective,randomized trial was undertaken to evaluate the utility of adding end-tidal capnometry(ETC)to pulse oximetry(PO)in patients undergoing procedural sedation and analgesia(PSA)in the emergency department(ED).METHODS:The patients were randomized to monitoring with or without ETC in addition to the current standard of care.Primary endpoints included respiratory adverse events,with secondary endpoints of level of sedation,hypotension,other PSA-related adverse events and patient satisfaction.RESULTS:Of 986 patients,501 were randomized to usual care and 485 to additional ETC monitoring.In this series,48%of the patients were female,with a mean age of 46 years.Orthopedic manipulations(71%),cardioversion(12%)and abscess incision and drainage(12%)were the most common procedures,and propofol and fentanyl were the sedative/analgesic combination used for most patients.There was no difference in patients experiencing de-saturation(Sa O2<90%)between the two groups;however,patients in the ETC group were more likely to require airway repositioning(12.9%vs.9.3%,P=0.003).Hypotension(SBP<100 mm Hg or<85 mm Hg if baseline<100 mm Hg)was observed in 16(3.3%)patients in the ETC group and 7(1.4%)in the control group(P=0.048).CONCLUSIONS:The addition of ETC does not appear to change any clinically significant outcomes.We found an increased incidence of the use of airway repositioning maneuvers and hypotension in cases where ETC was used.We do not believe that ETC should be recommended as a standard of care for the monitoring of patients undergoing PSA. 展开更多
关键词 Procedural sedation and analgesia capnography Adverse events Emergency medicine
下载PDF
Novel device for monitoring respiratory rate during endoscopy-A thermodynamic sensor
8
作者 Vaibhav Wadhwa Adalberto J Gonzalez +3 位作者 Kristen Selema Ronen Feldman Rocio Lopez John J Vargo 《World Journal of Gastrointestinal Pharmacology and Therapeutics》 CAS 2019年第3期57-66,共10页
BACKGROUND Monitoring ventilation accurately is an indispensable aspect of patient care in procedural settings.The current gold standard method of monitoring ventilation is by measuring exhaled carbon dioxide concentr... BACKGROUND Monitoring ventilation accurately is an indispensable aspect of patient care in procedural settings.The current gold standard method of monitoring ventilation is by measuring exhaled carbon dioxide concentration,known as capnography.A new device utilizing thermodynamic measurement,the Linshom Respiratory Monitoring Device(LRMD),has been designed to measure respiratory rate(RR)by using the temperature of exhaled breath.We hypothesized that the temperature sensor is at least equivalent in accuracy to capnography in monitoring ventilation.AIM To determine if the temperature sensor is equivalent to capnography in monitoring procedural ventilation.METHODS In this prospective study,participants were individually fitted with a face mask monitored by both LRMD and capnography.The following data were collected:gender,age,body mass index,type of procedure,and doses of medication.For each patient,we report the mean RR for each device as well as the mean difference.All analyses were performed using SAS,and a P<0.05 was considered statistically significant.RESULTS Twelve consecutive patients undergoing endoscopic procedures at our institution were enrolled.Four patients were excluded due to incomplete data,inadequate data,patient cooperation,and capnography failure.Overall,we found that LRMD RR highly correlated to capnography RR(P<0.001);the average capnography RR increases by 0.66 breaths for every one additional breath measured by the LRMD.In addition,apnea rates were 7.4%for the capnography and 6.4%for the LRMD(95%confidence interval:0.92-1.10).CONCLUSION The LRMD correlated with the gold standard capnography with respect to respiratory rate detection and apnea events.The LRMD could be used as an alternative to capnography for measuring respiration in endoscopy. 展开更多
关键词 SEDATION capnography Linshom THERMODYNAMIC SENSOR ENDOSCOPY
下载PDF
Comparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia
9
作者 Basavana Gouda Goudra Lakshmi C. Penugonda +1 位作者 Rebecca M. Speck Ashish C. Sinha 《Open Journal of Anesthesiology》 2013年第2期74-79,共6页
Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized pa... Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for upper gastrointestinal endoscopy with propofol-based anesthesia. Interventions: Patients were monitored for respiration rate with acoustic respiration rate monitoring, capnometry and impedance pneumography and values were compared to the manual counting of breaths by observation of chest wall movements. Additionally, when any respiration rate monitor indicated a cessation of breathing for 30 seconds or greater, the presumed apnea was confirmed by direct observation of the patient for absence of chest wall movements. Measurements and Main Results: Bias and precision for respiration rate measurement was 0 ± 1.0 bpm for acoustic monitoring, 4.8 ± 15.1 bpm for capnometry and 0.4 ± 5.9 bpm for impedance pneumography. Sensitivity and specificity for detection of apnea was 73% and 93% for acoustic monitoring, 73% and 12% for capnometry and 45% and 93% for impedance pneumography. Conclusions: Acoustic respiration rate monitoring was found to be accurate for assessment of respiration rate and to have similar or better sensitivity and specificity for detection of apnea compared to capnometry and impedance pneumography in the setting of upper GI endoscopy. 展开更多
关键词 capnography Endoscopy Monitoring PHYSIOLOGIC Respiratory Rate
下载PDF
Validation of Novel Completely Sealed Nasal Positive Airway Pressure Device: SuperNO<sub>2</sub>VA™EtCO<sub>2</sub>Measurement and Pressure Test Performance
10
作者 Michael J. Pedro Steven H. Cataldo 《Open Journal of Anesthesiology》 2020年第10期337-348,共12页
<b><span style="font-family:Verdana;">Background: </span></b><span style="font-family:Verdana;">SuperNO</span><sub><span style="vertical-align:sub;... <b><span style="font-family:Verdana;">Background: </span></b><span style="font-family:Verdana;">SuperNO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;">VA</span><sup><span style="vertical-align:super;font-family:Verdana;">&trade;</span></sup><span> </span><span style="font-family:Verdana;">Et Nasal Mask (Vyaire Medical, Inc., United States) is a new nasal mask with an integrated sampling hood to capture exhaled gases and enable accurate measurements of end tidal carbon dioxide (EtCO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;">). The authors hypothesized that the SuperNO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;">VA Et design would measure EtCO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;"> more accurately than a predicate EtCO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;"> sampling line, the Smart CapnoLine<sup><span style="white-space:nowrap;"><span style="white-space:nowrap;">&#174;</span></span></sup> Plus, Adult/Intermediate CO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;"> Oral-Nasal Set (Medtronic, United States). </span><b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> A simulated patient setup enabled comparison of the accuracy of CO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;"> measurements within the SuperNO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-family:Verdana;">VA Et and a predicate device for eight condition combinations of input CO</span><sub><span style="vertical-align:sub;font-family:Verdana;">2</span></sub><span style="font-fa 展开更多
关键词 capnography SEDATION HYPOXEMIA HYPOVENTILATION Ventilation
下载PDF
A lightweight mainstream capnometer with very low dead space volume is useful monitor for neonates with spontanous and mechanical ventilation: Pilot study
11
作者 Daijiro Takahashi Miyu Matsui +1 位作者 Takehiko Hiroma Tomohiko Nakamura 《Open Journal of Pediatrics》 2012年第2期127-132,共6页
Objects: The purpose of this study was to observe a correlation between PETCO2 and PaCO2 in intubated neonates under intermittent mandatory ventilation with spontaneous breathing. Material and methods: A total of 55 p... Objects: The purpose of this study was to observe a correlation between PETCO2 and PaCO2 in intubated neonates under intermittent mandatory ventilation with spontaneous breathing. Material and methods: A total of 55 paired PETCO2 measured by mainstream capnometry and PaCO2 values were obtained from 4 intubated neonates in our neonatal intensive care units at Nagano Children’s Hospital, Nagano, Japan. Results: PETCO2 and PaCO2 were significantly correlated (r2 = 0.928, p ETCO2 and mean PETCO2 correlated strongly with PaCO2 (maximum PETCO2: r2 = 0.9401, p ETCO2: r2 = 0.8587, p 2 also correlated with minimum PETCO2 (r2 = 0.2884, p ETCO2 (p ETCO2 (p 2 and PETCO2. Conclusion: Present study showed that a good correlation exists between PETCO2 and PaCO2 in intubated neonates under intermittent mandatory ventilation with spontaneous breathing. Lightweight with low amounts of dead space mainstream capnometry can be used as noninvasive monitor in incubated neonates with spontaneous breathing. 展开更多
关键词 capnography NEONATE
下载PDF
肺阻抗图用于判断患者气管插管位置准确性的临床研究 被引量:2
12
作者 姚永兴 姜桢 +3 位作者 陆霞晖 贺吉辉 马晓旭 祝继洪 《中华医学杂志》 CAS CSCD 北大核心 2007年第13期898-901,共4页
目的研究肺阻抗图用于判断气管插管位置正确性的应用价值。方法需插管全身麻醉患者36例,在气管插管成功后插入相同口径的气管导管至食管,一人将螺纹管接于气管或食管后挤压呼吸皮囊,另两人(有经验者和无经验者)分别用肺阻抗图法、呼末... 目的研究肺阻抗图用于判断气管插管位置正确性的应用价值。方法需插管全身麻醉患者36例,在气管插管成功后插入相同口径的气管导管至食管,一人将螺纹管接于气管或食管后挤压呼吸皮囊,另两人(有经验者和无经验者)分别用肺阻抗图法、呼末二氧化碳图(P_(et)CO_2)法和听诊法判断接上的是气管还是食管,记录正确性和作出判断所需要的时间。结果共进行了216次判断。正确率:阻抗法和 P_(et)CO_2法均正确判断了气管和食管插管,两者正确率差异无统计学意义;听诊法有经验者(n=72次)气管误判为食管2次,食管误判为气管1次;听诊法无经验者(n=72次)气管误判为食管5次,食管误判为气管9次,总正确率(81%)与有经验者(96%)比较,差异有统计学意义(P<0.01),与阻抗法和 P_(et)CO_2法比较,差异有统计学意义(P<0.01);阻抗法和 P_(et)CO_2法总的敏感度和特异性均为1,听诊法总的敏感度为0.90,特异性为0.86。作出判断所需时间:在3种方法中,无论判断气管还是食管,阻抗法与听诊法所需的时间差异无统计学意义;P_(et)CO_2法作出判断所需的时间最长(3.4 s±1.3s 和3.7s±1.4 s),与阻抗法(1.6 s±0.3 s 和2.1 8±1.1 s)和听诊法(1.7 s±0.7 s 和2.5 s±1.7 s)比较,差异有统计学意义(P<0.01)。用阻抗法或听诊法判断气管所需的时间(1.6 s±0.3 s)比用同样的方法判断食管所需的时间(2.1 s±1.1 s)短,差异有统计学意义(P<0.01)。结论阻抗法判断气管插管位置的正确率与 P_(et)CO_2法一致,而所需时间比 P_(et)CO_2法短,是判断气管插管位置正确性的有效方法之一。 展开更多
关键词 插管法 气管内 听诊 二氧化碳描记术
原文传递
容量-呼气末二氧化碳分压波在危重患者中临床应用解析 被引量:1
13
作者 江学成 《国际麻醉学与复苏杂志》 CAS 2011年第4期497-501,共5页
背景容量-呼气末二氧化碳分压图(volume-capnogram,v-PETCO2)是根据呼吸周期中呼出气量对应CO2水平描记的单波图,是评价呼吸障碍患者死腔或分流的最有价值的无创性新工具。目的讲述v-PETCO2的基本原理、正常波形和异常波形的临床意... 背景容量-呼气末二氧化碳分压图(volume-capnogram,v-PETCO2)是根据呼吸周期中呼出气量对应CO2水平描记的单波图,是评价呼吸障碍患者死腔或分流的最有价值的无创性新工具。目的讲述v-PETCO2的基本原理、正常波形和异常波形的临床意义。内容v-PETCO2波的形态取决于CO2产生、运输(肺灌注)和弥散以及任何原因引起的肺病理生理学改变,可用来更好地了解和研究CO2动力学过程。v-PETCO2有3个呼气相:相I,呼出的为无CO2的气道气体,相Ⅱ是气道和肺泡混合气体,相Ⅲ完全是肺泡气体。呼吸障碍时通气催注比率不匹配,导致肺泡序贯性排空,呼出气CO2水平不同,v-PETCO2波的相Ⅲ斜率增加,解剖死腔、肺泡死腔和/或生理死腔及及其计算参数增加。根据v-PETCO2波的相Ⅲ斜率能将肺栓塞与肺疾患轻易区别,通过死腔参数较精确地评价急性呼吸窘迫综合征(acute respiratory distresssyndrome,ARDS)、哮喘、慢性阻塞性肺病(chronic obstructive pulmonary diseases,COPD)等严重程度和鉴别。趋向PETCO2波对危重患者肺功能临床评价和研究具有突破性贡献和非常高的价值。 展开更多
关键词 呼气末二氧化碳分压 呼气末二氧化碳分压波 容量-PETCO2波 呼吸 通气
原文传递
呼气末二氧化碳监测在临床麻醉中的应用与研究进展
14
作者 舒进军 谷茜 +2 位作者 曾德玲 王怀明 邹江 《国际麻醉学与复苏杂志》 CAS 2023年第9期970-974,共5页
呼气末二氧化碳(end-tidal carbon dioxide, EtCO_(2))作为一种无创的监测方式, 广泛应用于各类手术的术中监测, PETCO_(2)不仅反映机体的呼吸功能, 也可以反映机体的循环功能和代谢功能。文章总结了EtCO_(2)在临床麻醉中对严重过敏反... 呼气末二氧化碳(end-tidal carbon dioxide, EtCO_(2))作为一种无创的监测方式, 广泛应用于各类手术的术中监测, PETCO_(2)不仅反映机体的呼吸功能, 也可以反映机体的循环功能和代谢功能。文章总结了EtCO_(2)在临床麻醉中对严重过敏反应、肺动脉灌注障碍、气体栓塞以及恶性高热协助诊断的应用价值, 并对PETCO_(2)与术后谵妄、术后肺部并发症、术后恶心呕吐相关性的研究进行综述, 以期通过PETCO_(2)监测来协助判断临床麻醉中出现的相应变化, 早期发现并及时处理, 改善患者的预后。 展开更多
关键词 呼气末二氧化碳 二氧化碳描记图 麻醉
原文传递
二氧化碳浓度测量法在诊断睡眠呼吸暂停综合征中的应用研究
15
作者 刘升明 《医师进修杂志》 北大核心 2002年第3期20-21,共2页
目的 同时采用热敏传感器和二氧化碳浓度测量仪监测睡眠呼吸暂停综合征 (SAS)患者 ,探讨二氧化碳浓度测量法在诊断SAS中的临床价值。方法 对 2 5例患者进行多导睡眠图和呼出气二氧化碳浓度描记图及呼气末二氧化碳分压 (PetCO2 )监测 ... 目的 同时采用热敏传感器和二氧化碳浓度测量仪监测睡眠呼吸暂停综合征 (SAS)患者 ,探讨二氧化碳浓度测量法在诊断SAS中的临床价值。方法 对 2 5例患者进行多导睡眠图和呼出气二氧化碳浓度描记图及呼气末二氧化碳分压 (PetCO2 )监测 ,并对PetCO2 值与呼吸紊乱指数 (AHI)的关系进行分析 ,统计方法采用t检验和相关分析。结果 以热敏传感器所得结果为标准 ,呼吸暂停、低通气和呼吸紊乱阳性诊断率分别为 84.5 %± 9.6 % ,72 .7%± 8.0 % ,81.2 %± 8.4% ;未发现假阳性。夜间平均PetCO2 和最高PetCO2 与窒息指数 (AI)、低通气指数(HI)、AHI均无显著相关性。结论 二氧化碳浓度测量法监测SAS具有较高的诊断率。 展开更多
关键词 睡眠呼吸暂停综合征 二氧化碳浓度测量法 呼气末二氧化碳分压 诊断
下载PDF
二氧化碳图及其在呼吸系统疾病中的应用及进展
16
作者 耿茜 高怡 +1 位作者 王译民 郑劲平 《国际呼吸杂志》 2021年第9期709-715,共7页
呼出气二氧化碳图既往主要用于麻醉、重症监护等领域,但随着设备技术发展,衍生多个测量参数,使其不再局限于监护范畴,而是作为类似一种肺功能检测方法应用于呼吸系统疾病。该技术简单且无创,对患者的配合度要求相对较小。其部分指标与... 呼出气二氧化碳图既往主要用于麻醉、重症监护等领域,但随着设备技术发展,衍生多个测量参数,使其不再局限于监护范畴,而是作为类似一种肺功能检测方法应用于呼吸系统疾病。该技术简单且无创,对患者的配合度要求相对较小。其部分指标与其他肺功能指标的相关性提示二氧化碳图检查可在呼吸系统疾病的筛查诊断、病情严重程度判定以及治疗效果评估中发挥作用;其联合血气分析也可作为肺栓塞的初筛依据。本文综述了呼出气二氧化碳检测技术,介绍了2种二氧化碳图阶段特征及其测量指标,并总结了呼出气二氧化碳图在呼吸系统疾病中的应用及作为肺功能检查技术的优缺点。 展开更多
关键词 二氧化碳图 肺功能检查 呼吸系统疾病
原文传递
呼气末二氧化碳监测在多道睡眠监测中的应用
17
作者 陈惟虎 叶京英 +1 位作者 张玉焕 王江咏 《中华耳鼻咽喉头颈外科杂志》 CAS CSCD 北大核心 2013年第2期158-160,共3页
目的探讨呼气末二氧化碳分压(pressureofend—tidalcarbondioxideconcentration,PETCO2)的监测在阻塞性睡眠呼吸暂停低通气综合征(OSAHS)患者整夜多道睡眠图(PSG)监测中的应用及意义。方法对38例OSAHS患者行整夜同步PSG和PETCO2... 目的探讨呼气末二氧化碳分压(pressureofend—tidalcarbondioxideconcentration,PETCO2)的监测在阻塞性睡眠呼吸暂停低通气综合征(OSAHS)患者整夜多道睡眠图(PSG)监测中的应用及意义。方法对38例OSAHS患者行整夜同步PSG和PETCO2监测,将PETCO:波形耦合到PSG中,观察记录PETCO2波形特点和数值,并与PSG相关指标行相关性分析。结果睡眠期间呼吸平稳状态下PETCO2呈现梯形波,呼吸暂停时波形表现为一直线,低通气时呼气末平台的缩短或消失。非快动眼睡眠期、快动眼睡眠期以及整夜总睡眠时间的PETCO2平均值与呼吸暂停低通气指数及微觉醒指数呈负相关趋势(r值-0.458--0.688,P值均〈0.01),与最低及夜间平均动脉血氧饱和度呈正相关趋势(r值0.604—0.674,P值均〈0.01)。结论PETCO2的监测可应用于PSG,睡眠期间PETCO,的平均值在一定程度上能反映OSAHS患者呼吸紊乱的严重程度。 展开更多
关键词 睡眠呼吸暂停 阻塞性 二氧化碳描记术 多道睡眠描记术
原文传递
二氧化碳图在阻塞性肺疾病中的临床应用进展
18
作者 孙晓丽 刘锦铭 杨文兰 《国际呼吸杂志》 2009年第23期1458-1460,共3页
二氧化碳图是一种具有发展前景和临床实用价值的肺功能测定技术。该技术通过测量分析呼出气二氧化碳的水平,以及一系列参数指标的变化来评估肺内不同疾病状态下的病理生理状况的改变。近年来随着研究的深入,二氧化碳图在阻塞性肺疾病... 二氧化碳图是一种具有发展前景和临床实用价值的肺功能测定技术。该技术通过测量分析呼出气二氧化碳的水平,以及一系列参数指标的变化来评估肺内不同疾病状态下的病理生理状况的改变。近年来随着研究的深入,二氧化碳图在阻塞性肺疾病治疗评估方面有了新的突破和意义。 展开更多
关键词 二氧化碳图 慢性阻塞性肺疾病 支气管哮喘
原文传递
容积二氧化碳图对支气管哮喘患者急性加重分级的意义 被引量:7
19
作者 刘锦铭 胡华成 +3 位作者 施敏华 杨文兰 郑卫 王英敏 《中华结核和呼吸杂志》 CAS CSCD 北大核心 2008年第3期186-190,共5页
目的探讨容积二氧化碳图(VCap)参数对支气管哮喘(简称哮喘)诊断的临床价值。方法2006年7月至2007年5月对64例哮喘急性发作期患者(哮喘组)及20名健康者(健康对照组)进行肺通气功能以及VCap测定,并依据FEV1占预计值%将哮喘患者... 目的探讨容积二氧化碳图(VCap)参数对支气管哮喘(简称哮喘)诊断的临床价值。方法2006年7月至2007年5月对64例哮喘急性发作期患者(哮喘组)及20名健康者(健康对照组)进行肺通气功能以及VCap测定,并依据FEV1占预计值%将哮喘患者分为A组(〉80%,18例)、B组(40%~80%,26例)、C组(〈40%,20例),所有受试者先行VCap测定,随后完成FEV1占预计值%、FEV1/FVC、FVC占预计值%、最大呼气中段流量(MMEF)占预计值%测定。统计学处理采用SPSS 13.0软件。计量资料采用元^-x±s表示,计数资料采用卡方检验,计量资料两组间比较采用t检验。肺通气参数与VCap参数间的相关性采用一元线性回归检验;哮喘组与对照组间的差异采用独立样本t检验;健康对照组及哮喘各亚组间的比较采用单因素方差分析。结果哮喘组患者FEV1占预计值%、FEV1/FVC、PEF占预计值%、MMEF占预计值%分别为(52±20)%、(50±10)%、(49±16)%、(28±16)%,与健康对照组[(98±9)%、(80±6)%、(91±15)%、(73±7)%]比较差异有统计学意义(t值分别为6.93~13.29,P均〈0.01);哮喘组患者Ⅱ期斜率(dC2/DV)、Ⅲ期斜率(dC3/DV)、Ⅲ期与Ⅱ期斜率之比(SR23)分别为(19±6)%/L、(2.9±1.2)%/L、(16.8±10.6)%,与健康对照组[(31±8)%/L、(1.0±0.4)%/L,(3.3±1.5)%]比较差异有统计学意义(t值分别为5.09、-6.14、-6.54,P均〈0.01);哮喘B、C组dC2/DV分别为(17±5)%/L、(13±4)%/L,与健康对照组[(31±8)%/L]比较差异有统计学意义(t=-11.82、-16.75,P均〈0.01);哮喘B、C组患者dC3/DV、SR23分别为(3.2±0.8)%/L、(17.2±3.5)%,(4.1±1.2)%/L、(28.3±6.9)%,与健康对照组[(1.0±0.4)%/L、(3� 展开更多
关键词 哮喘 呼吸功能试验 容积二氧化碳图
原文传递
死腔测定在支气管哮喘中应用价值的研究 被引量:7
20
作者 齐广生 刘锦铭 +3 位作者 高蓓兰 储海青 杨文兰 郑卫 《国际呼吸杂志》 2009年第7期402-405,共4页
目的探讨容积二氧化碳图(volumetric capnography,VCap)技术死腔测定在支气管哮喘(简称哮喘)中的应用价值及临床意义。方法对52例急性发作期哮喘患者及35名健康志愿者的常规肺功能指标及Langley死腔(VDL)、Fowler死腔(VDF)、wo... 目的探讨容积二氧化碳图(volumetric capnography,VCap)技术死腔测定在支气管哮喘(简称哮喘)中的应用价值及临床意义。方法对52例急性发作期哮喘患者及35名健康志愿者的常规肺功能指标及Langley死腔(VDL)、Fowler死腔(VDF)、wolff死腔(VDW)进行测定分析。结果本研究显示:哮喘组中VDL、VDF及VDW均较对照组显著减小(P〈0.01,0.01,0.01)。相关分析显示:VDL、VDF和VDW分别与FEV1占预计值%、FEV1/FVC%、PEF占预计值%、FEF25占预计值%、FEF50占预计值%、FEF75占预计值%、MMEF占预计值%呈负相关(P〈0.05),与RV占预计值%、TLC占预计值%、RV/TLC%呈正相关(P〈0.05)。结论VCap死腔测定患者易于配合,对哮喘的辅助诊断及进一步了解其病理生理改变具有一定的临床价值和意义。 展开更多
关键词 哮喘 死腔 容积二氧化碳图
原文传递