In order to ascertain the effects of atmospheric pressure on developmental characteristics and the stability of AEA(air-entraining agent)solution bubbles,AEA solution experiments and AEA solution bubble experiments we...In order to ascertain the effects of atmospheric pressure on developmental characteristics and the stability of AEA(air-entraining agent)solution bubbles,AEA solution experiments and AEA solution bubble experiments were,respectively,conducted in Peking(50 m,101.2 kPa)and Lhasa(3,650 m,63.1 kPa).Surface tensions and inflection-point concentrations were tested based on AEA solutions,whilst developmental characteristics,thicknesses and elastic coefficients of liquid films were tested based on air bubbles of AEA solutions.The study involved three types of AEAs,which were TM-O,226A,and 226S.The experimental results show that initial sizes of TM-O,226A,and 226S are,respectively,increased by 43.5%,17.5%,and 3.8%.With the decrease of ambient pressure,the drainage rate and the drainage index of AEA solution bubbles increase.Interference experiments show that the liquid film thicknesses of all tested AEA solution bubbles are in micron scales.When the atmospheric pressure decreases from 101.2 to 63.1 kPa,the liquid film thicknesses of three types of AEA solutions decrease in various degrees;and film elasticities at critical thicknesses increase.Liquid film of 226S solution bubbles is the most stable,presenting as a minimum thickness variation.It should be noted that elastic coefficient of liquid film only represents the level at critical thickness,thus it can not be applied as the only evaluating indicator of bubble stability.For a type of AEA,factors affecting the stability of its bubbles under low atmospheric pressure include initial bubbles size,liquid film thickness,liquid film elasticity,ambient temperature,etc.展开更多
The hydrodynamic study of the liquid film around Taylor bubbles in slug flow has great significance for understanding parallel flow and interaction between Taylor bubbles.The prediction models for liquid film thicknes...The hydrodynamic study of the liquid film around Taylor bubbles in slug flow has great significance for understanding parallel flow and interaction between Taylor bubbles.The prediction models for liquid film thickness mainly focus on stagnant flow,and some of them remain inaccurate performance.However,in the industrial process,the slug flow essentially is co-current flow.Therefore,in this paper,the liquid film thickness is studied by theoretical analysis and experimental methods under two conditions of stagnant and co-current flow.Firstly,under the condition of stagnant flow,the present work is based on Batchelor's theory,and modifies Batchelor's liquid film thickness model,which effectively improves its prediction accuracy.Under the condition of co-current flow,the prediction model of average liquid film thickness in slug flow is established by force and motion analysis.Taylor bubble length is introduced into the model as an important parameter.Dynamic experiments were carried out in the pipe with an inner diameter of 20 mm.The liquid film thickness,Taylor bubble velocity and length were measured by distributed ultrasonic sensor and intrusive cross-correlation conductivity sensor.Comparing the predicted value of the model with the measured results,the relative error is controlled within 10%.展开更多
基金Funded by the National Natural Science Foundation of China(Nos.52178428,52178427,and 52308454)the Science and Technology Project of Tibet Department of Transportation(No.XZJTKJ[2020]04)。
文摘In order to ascertain the effects of atmospheric pressure on developmental characteristics and the stability of AEA(air-entraining agent)solution bubbles,AEA solution experiments and AEA solution bubble experiments were,respectively,conducted in Peking(50 m,101.2 kPa)and Lhasa(3,650 m,63.1 kPa).Surface tensions and inflection-point concentrations were tested based on AEA solutions,whilst developmental characteristics,thicknesses and elastic coefficients of liquid films were tested based on air bubbles of AEA solutions.The study involved three types of AEAs,which were TM-O,226A,and 226S.The experimental results show that initial sizes of TM-O,226A,and 226S are,respectively,increased by 43.5%,17.5%,and 3.8%.With the decrease of ambient pressure,the drainage rate and the drainage index of AEA solution bubbles increase.Interference experiments show that the liquid film thicknesses of all tested AEA solution bubbles are in micron scales.When the atmospheric pressure decreases from 101.2 to 63.1 kPa,the liquid film thicknesses of three types of AEA solutions decrease in various degrees;and film elasticities at critical thicknesses increase.Liquid film of 226S solution bubbles is the most stable,presenting as a minimum thickness variation.It should be noted that elastic coefficient of liquid film only represents the level at critical thickness,thus it can not be applied as the only evaluating indicator of bubble stability.For a type of AEA,factors affecting the stability of its bubbles under low atmospheric pressure include initial bubbles size,liquid film thickness,liquid film elasticity,ambient temperature,etc.
基金supported by National Natural Science Foundation of China(42074142,51527805)。
文摘The hydrodynamic study of the liquid film around Taylor bubbles in slug flow has great significance for understanding parallel flow and interaction between Taylor bubbles.The prediction models for liquid film thickness mainly focus on stagnant flow,and some of them remain inaccurate performance.However,in the industrial process,the slug flow essentially is co-current flow.Therefore,in this paper,the liquid film thickness is studied by theoretical analysis and experimental methods under two conditions of stagnant and co-current flow.Firstly,under the condition of stagnant flow,the present work is based on Batchelor's theory,and modifies Batchelor's liquid film thickness model,which effectively improves its prediction accuracy.Under the condition of co-current flow,the prediction model of average liquid film thickness in slug flow is established by force and motion analysis.Taylor bubble length is introduced into the model as an important parameter.Dynamic experiments were carried out in the pipe with an inner diameter of 20 mm.The liquid film thickness,Taylor bubble velocity and length were measured by distributed ultrasonic sensor and intrusive cross-correlation conductivity sensor.Comparing the predicted value of the model with the measured results,the relative error is controlled within 10%.