Based on the commonly used indicators for speech intelligibility, this work acoustically evaluates the two largest auditoria in the Faculty of Engineering, Helwan University, Cairo, Egypt, using experimental and digit...Based on the commonly used indicators for speech intelligibility, this work acoustically evaluates the two largest auditoria in the Faculty of Engineering, Helwan University, Cairo, Egypt, using experimental and digital simulation techniques. Design treatments were also suggested to improve the acoustic performance of the auditoria, where the impact of these treatments was checked using the simutation as well. The models that were analysed using the CATT-software were first validated utilizing the results of the fietd work in the unoccupied rooms. The results showed that the acoustic quality of the two auditoria are far from the optimal conditions due to their improper acoustic characteristics and the high noise revers as weft. The results of improvement proposals showed that altering the ceiling shape and adding efficient absorptive materials to the rear surfaces successfully reduced the excessive reverberation time to the optimal values, increased the earty reflections and eliminated the shadow zones. In addition, decreasing the noise Levels by 20 dB due to improving the window insulation noticeably improved the speech intelligibitity at all receivers.展开更多
文摘Based on the commonly used indicators for speech intelligibility, this work acoustically evaluates the two largest auditoria in the Faculty of Engineering, Helwan University, Cairo, Egypt, using experimental and digital simulation techniques. Design treatments were also suggested to improve the acoustic performance of the auditoria, where the impact of these treatments was checked using the simutation as well. The models that were analysed using the CATT-software were first validated utilizing the results of the fietd work in the unoccupied rooms. The results showed that the acoustic quality of the two auditoria are far from the optimal conditions due to their improper acoustic characteristics and the high noise revers as weft. The results of improvement proposals showed that altering the ceiling shape and adding efficient absorptive materials to the rear surfaces successfully reduced the excessive reverberation time to the optimal values, increased the earty reflections and eliminated the shadow zones. In addition, decreasing the noise Levels by 20 dB due to improving the window insulation noticeably improved the speech intelligibitity at all receivers.