期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia 被引量:4
1
作者 Islam M.Rizk Abd-Almonem A.Al-hessy +1 位作者 Sherief E.El-Khouly Ashraf M.Sewelam 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期284-290,共7页
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana... AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications. 展开更多
关键词 PHAKIC INTRAOCULAR lenses IMPLANTABLE collamer Visian V4c LENS foldable artiflex LENS
下载PDF
硬性和可折叠前虹膜固定人工晶状体植入治疗亚洲眼高度近视的疗效比较 被引量:1
2
作者 Nia Milastuti Indra Tri Mahayana +1 位作者 Suhardjo Agus Supartoto 《国际眼科杂志》 CAS 北大核心 2023年第6期887-893,共7页
目的:比较Artisan和Artiflex有晶状体眼人工晶状体(PIOL)矫正亚洲人群高度近视的屈光度和安全性。方法:历史队列研究。回顾2016/2020在印度尼西亚日惹市Yap眼科医院接受PIOL植入术的81例高度近视眼。根据植入PIOL分为Artisan组43眼,Arti... 目的:比较Artisan和Artiflex有晶状体眼人工晶状体(PIOL)矫正亚洲人群高度近视的屈光度和安全性。方法:历史队列研究。回顾2016/2020在印度尼西亚日惹市Yap眼科医院接受PIOL植入术的81例高度近视眼。根据植入PIOL分为Artisan组43眼,Artiflex组38眼。分别记录术前及术后1d、1、3mo的视力、角膜生物显微镜参数和眼压,包括术前前房深度。结果:Artisan和Artiflex组的平均随访时间分别为9.64±6.93mo和8.96±4.28mo(P=0.736)。Artisan组的疗效指数为1.03±0.47,Artiflex组为1.02±0.17(P=0.119);安全性指数分别为1.10±0.45和1.05±0.21(P<0.001)。Artisan组的平均等效球镜度(SE)为-0.64±0.996D,Artiflex组为-0.22±0.58D(P=0.076)。两组术后内皮细胞密度(ECD)较术前均显著下降(P<0.05),累积ECD缺失率为7.44%和5.79%(P=0.418)。结论:Artisan和Artiflex矫正亚洲人高度近视的屈光效果相当。与Artiflex相比,Artisan的安全指数略高,而两组的疗效指数和累积ECD缺失率相似。 展开更多
关键词 有晶状体眼人工晶状体 前虹膜固定 ARTISAN artiflex 内皮细胞密度 高度近视
下载PDF
上一页 1 下一页 到第