In this study, graphitic carbon nitride deposited silica(g-C3N4@SiO2) was prepared by simple pyrolysis of melamine on silica and then used as a solid-phase extraction(SPE) sorbent for the extraction of four repres...In this study, graphitic carbon nitride deposited silica(g-C3N4@SiO2) was prepared by simple pyrolysis of melamine on silica and then used as a solid-phase extraction(SPE) sorbent for the extraction of four representative aromatic acids including benzoic acid(BA), salicylic acid(SA), indolyl-3-butyricacid(IBA) and naphthalene acetic acid(NAA) in coconut water(CW) samples, g-C3N4@SiO2 exhibited an excellent adsorption capacity for the four aromatic acids, which are in the concentration range of 500--558.8 gg/g. The four aromatic acids could be directly captured by g-C3N4@SiO2 from CW samples within 5 rain. Thus, a rapid, simple and effective method for the analy- sis of four aromatic acids in CW samples was developed by coupling g-C3N4@SiO2-based SPE with high performance liquid chromatography-ultraviolet(HPLC-UV) detection. The linearity of the developed method was in the range of 20--1000 ng/mL and its limit of detection was in the range of 1.9--5.7 ng/mL, which were signi- ficantly lower than those of the reported similar methods. The intra-day and inter-day precisions(based on the relative standard deviation, n=3) of the four aromatic acids were under 9.5% and 10.4%, respectively. The developed method was applied to determining the four aromatic acids in real CW samples and the spiked recoveries varied from 81.1% to 121.8%.展开更多
基金Supported by the National Natural Science Foundation of China(Nos.31671929, 21475098) and the Fundamental Research Funds for the Central Universities of China.
文摘In this study, graphitic carbon nitride deposited silica(g-C3N4@SiO2) was prepared by simple pyrolysis of melamine on silica and then used as a solid-phase extraction(SPE) sorbent for the extraction of four representative aromatic acids including benzoic acid(BA), salicylic acid(SA), indolyl-3-butyricacid(IBA) and naphthalene acetic acid(NAA) in coconut water(CW) samples, g-C3N4@SiO2 exhibited an excellent adsorption capacity for the four aromatic acids, which are in the concentration range of 500--558.8 gg/g. The four aromatic acids could be directly captured by g-C3N4@SiO2 from CW samples within 5 rain. Thus, a rapid, simple and effective method for the analy- sis of four aromatic acids in CW samples was developed by coupling g-C3N4@SiO2-based SPE with high performance liquid chromatography-ultraviolet(HPLC-UV) detection. The linearity of the developed method was in the range of 20--1000 ng/mL and its limit of detection was in the range of 1.9--5.7 ng/mL, which were signi- ficantly lower than those of the reported similar methods. The intra-day and inter-day precisions(based on the relative standard deviation, n=3) of the four aromatic acids were under 9.5% and 10.4%, respectively. The developed method was applied to determining the four aromatic acids in real CW samples and the spiked recoveries varied from 81.1% to 121.8%.