Computed tomography (CT)-guided lung biopsy is a common diagnostic procedure that is associated with various complications, including pneumothorax, hemoptysis and parenchymal hemorrhage. Systemic air embolism is a ver...Computed tomography (CT)-guided lung biopsy is a common diagnostic procedure that is associated with various complications, including pneumothorax, hemoptysis and parenchymal hemorrhage. Systemic air embolism is a very rare (0.07%) but potentially lifethreatening complication. We report a fatal case of air embolism to the cerebral and coronary arteries confirmed by head and chest CT, followed by a review of the literature.展开更多
Based on reasonable model hypotheses and the energy analysis of heat and mass transfer of air and water in a direct contact counter flow, a set of general equations that can describe the internal relationship between ...Based on reasonable model hypotheses and the energy analysis of heat and mass transfer of air and water in a direct contact counter flow, a set of general equations that can describe the internal relationship between the state parameters of air and water and dimensionless parameters of transfer process are given. A method utilizing MATLAB to solve these general equations is also proposed.Calculations and analysis with the model of a cooling- dehumidifying process give a consistent result with that of previous experiment.A new method for designing equipment such as evaporating cooler and cooling tower, and for analyzing experiment data of heat and mass transfer of air and water in a direct contact counter flow can be derived from this study.展开更多
One hundred and ten samples of rainwater were collected for chemical analysis at the summit of Huangshan Mountain, a high-altitude site in East China, from July 2010 to June 2011. The volume-weighted-mean (VWM) pH f...One hundred and ten samples of rainwater were collected for chemical analysis at the summit of Huangshan Mountain, a high-altitude site in East China, from July 2010 to June 2011. The volume-weighted-mean (VWM) pH for the whole sampling period was 5.03. SO2- and Ca2+ were the most abundant anion and cation, respectively. The ionic concentrations varied monthly with the highest concentrations in winter/spring and the lowest in summer. Evident inter-correlations were found among most ions, indicating the common sources for some species and fully mixing characteristics of the alpine precipitation chemistry. The VWM ratio of [SO]-]/[NO3] was 2.54, suggesting the acidity of rainwater comes from both nitric and sulfuric acids. Compared with contemporary observations at other alpine continental sites in China, the precipitation at Huangshan Mountain was the least polluted, with the lowest ionic concentrations. Trajectories to Huangshan Mountain on rainy days could be classified into six groups. The rainwater with influencing air masses originating in Mongolia was the most polluted with limited effect. The emissions of Jiangxi, Anhui, Zhejiang and Jiangsu provinces had a strong influence on the overall rain chemistry at Huangshan Mountain. The rainwater with influencing air masses from Inner Mongolia was heavily polluted by anthropogenic pollutants.展开更多
This review intends to cover a range of brief description of the generation mechanisms,the determination of the concentration,and the identification of negative air ions(NAI).This is divided into two parts:(i)it pays ...This review intends to cover a range of brief description of the generation mechanisms,the determination of the concentration,and the identification of negative air ions(NAI).This is divided into two parts:(i)it pays attention to the generation of NAI,which contains natural and artificial methods.According to the variation of energy in the environment,different methods based on natural generation are introduced in detail.As for artificial generation of NAI,corona discharge is dominantly elaborated due to its preponderance in convenient to control of the concentration of ions.(ii)it tends to introduce the determination of NAI,containing quantitative and qualitative detection,by using ion counting device and mass spectrometer,respectively.展开更多
文摘Computed tomography (CT)-guided lung biopsy is a common diagnostic procedure that is associated with various complications, including pneumothorax, hemoptysis and parenchymal hemorrhage. Systemic air embolism is a very rare (0.07%) but potentially lifethreatening complication. We report a fatal case of air embolism to the cerebral and coronary arteries confirmed by head and chest CT, followed by a review of the literature.
文摘Based on reasonable model hypotheses and the energy analysis of heat and mass transfer of air and water in a direct contact counter flow, a set of general equations that can describe the internal relationship between the state parameters of air and water and dimensionless parameters of transfer process are given. A method utilizing MATLAB to solve these general equations is also proposed.Calculations and analysis with the model of a cooling- dehumidifying process give a consistent result with that of previous experiment.A new method for designing equipment such as evaporating cooler and cooling tower, and for analyzing experiment data of heat and mass transfer of air and water in a direct contact counter flow can be derived from this study.
基金supported by funds from the Scientific Research Projects of High-level Talents of the Department of Human Resources and Social Security of Anhui Province (Grant No.2009Z019)the State Key Laboratory of Atmospheric Boundary Physics and Atmospheric Chemistry (Grant No.LAPC-KF-201105)
文摘One hundred and ten samples of rainwater were collected for chemical analysis at the summit of Huangshan Mountain, a high-altitude site in East China, from July 2010 to June 2011. The volume-weighted-mean (VWM) pH for the whole sampling period was 5.03. SO2- and Ca2+ were the most abundant anion and cation, respectively. The ionic concentrations varied monthly with the highest concentrations in winter/spring and the lowest in summer. Evident inter-correlations were found among most ions, indicating the common sources for some species and fully mixing characteristics of the alpine precipitation chemistry. The VWM ratio of [SO]-]/[NO3] was 2.54, suggesting the acidity of rainwater comes from both nitric and sulfuric acids. Compared with contemporary observations at other alpine continental sites in China, the precipitation at Huangshan Mountain was the least polluted, with the lowest ionic concentrations. Trajectories to Huangshan Mountain on rainy days could be classified into six groups. The rainwater with influencing air masses originating in Mongolia was the most polluted with limited effect. The emissions of Jiangxi, Anhui, Zhejiang and Jiangsu provinces had a strong influence on the overall rain chemistry at Huangshan Mountain. The rainwater with influencing air masses from Inner Mongolia was heavily polluted by anthropogenic pollutants.
基金Supported by the National High Technology Research and Development program ("863" Program) of China (Name: Key technique research of high-speed trimaranNumber:2006AA11Z227)
基金This work was financially supported by the National Natural Science Foundation of China(No.21621003)CERS-China Equipment and Education Resources System(No.CERS-1-75).
文摘This review intends to cover a range of brief description of the generation mechanisms,the determination of the concentration,and the identification of negative air ions(NAI).This is divided into two parts:(i)it pays attention to the generation of NAI,which contains natural and artificial methods.According to the variation of energy in the environment,different methods based on natural generation are introduced in detail.As for artificial generation of NAI,corona discharge is dominantly elaborated due to its preponderance in convenient to control of the concentration of ions.(ii)it tends to introduce the determination of NAI,containing quantitative and qualitative detection,by using ion counting device and mass spectrometer,respectively.