A field-scale aged refuse (AR) biofilter constructed in Shanghai Refuse Landfill, containing about 7000 m^3 aged refuse inside, was evaluated for its performance in the treatment of landfill leachate. This AR biofil...A field-scale aged refuse (AR) biofilter constructed in Shanghai Refuse Landfill, containing about 7000 m^3 aged refuse inside, was evaluated for its performance in the treatment of landfill leachate. This AR biofilter can be divided into three stages and can manage 50 m^3 landfill leachate per day. The physical, chemical, and biological characteristics of AR were analyzed for evaluating the AR biofilter as leachate treatment host. The results revealed that over 87.8%-96.2% of COD and 96.9%-99.4% of ammonia nitrogen were removed by the three-stage AR biofilter when the infiuent leachate COD and ammonia nitrogen concentration were in the range 5478-10842 mg/L and 811-1582 mg/L, respectively. The final effluent was inodorous and pale yellow with COD and ammonia nitrogen below 267-1020 mg/L and 6-45 mg/L, respectively. The three-stage AR biofilter had efficient nitrification but relative poor denitrification capacity with a total nitrogen (TN) removal of 58%-73%. The external temperature of AR biofilter did not influence the total ammonia nitrogen removal significantly. It was concluded that the scale-up AR biofilter can work very well and can be a promising technology for the treatment of landfill leachate.展开更多
基金supported by the Ministry of Education of China (No. 305005)the Science and Technology Commission of Shanghai Municipality (No. 05DZ12003).
文摘A field-scale aged refuse (AR) biofilter constructed in Shanghai Refuse Landfill, containing about 7000 m^3 aged refuse inside, was evaluated for its performance in the treatment of landfill leachate. This AR biofilter can be divided into three stages and can manage 50 m^3 landfill leachate per day. The physical, chemical, and biological characteristics of AR were analyzed for evaluating the AR biofilter as leachate treatment host. The results revealed that over 87.8%-96.2% of COD and 96.9%-99.4% of ammonia nitrogen were removed by the three-stage AR biofilter when the infiuent leachate COD and ammonia nitrogen concentration were in the range 5478-10842 mg/L and 811-1582 mg/L, respectively. The final effluent was inodorous and pale yellow with COD and ammonia nitrogen below 267-1020 mg/L and 6-45 mg/L, respectively. The three-stage AR biofilter had efficient nitrification but relative poor denitrification capacity with a total nitrogen (TN) removal of 58%-73%. The external temperature of AR biofilter did not influence the total ammonia nitrogen removal significantly. It was concluded that the scale-up AR biofilter can work very well and can be a promising technology for the treatment of landfill leachate.