Synergistic solvent extraction of rare earth elements (REEs) from nitrate medium was investigated with mixtures of 8-hydroxyquinoline (HQ) and acidic organophosphorus extractants, bis(2,4,4-trimethylpentyl) dith...Synergistic solvent extraction of rare earth elements (REEs) from nitrate medium was investigated with mixtures of 8-hydroxyquinoline (HQ) and acidic organophosphorus extractants, bis(2,4,4-trimethylpentyl) dithiophosphinic acid (Cyanex 301) and bis(2,4,4-trimethylpentyl) monothiophosphinic acid (Cyanex 302). The extraction behavior of Cyanex 301/Cyanex 302 and their binary mixtures with HQ towards several lanthanoids (La, Nd, Sm, Tb, Ho, Tm) and yttrium (Y) was investigated. The separation ability of REEs was studied according to the various extraction effects. The extraction mechanisms for yttrium were studied with the methods of slope analysis and constant moles in the synergistic systems. The extracted compounds, the equilibrium constants, and thermodynamic functions were also determined.展开更多
It was observed that the atomic fluorescence emission due to signal during the determination of As(Ⅲ) in the mixture of As(Ⅲ) and As(V) could has a 10% to 40% of fluorescence emission As(V). Besides, interfe...It was observed that the atomic fluorescence emission due to signal during the determination of As(Ⅲ) in the mixture of As(Ⅲ) and As(V) could has a 10% to 40% of fluorescence emission As(V). Besides, interferes from heavy metals such as Pb(Ⅱ), Cu(Ⅱ) can cause severe increase of the signals as compared to the insignificant effects caused by Cd(Ⅱ), Zn(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ). On the basis of further studies, the masking agent of 8-hydroxyquinoline was used as an efficient agent to eliminate interference of As(V) emission and the heavy metal of Cu^2+ and Pb^2+ in the measurements of arsenic species, After a series standard additions and CRM researches, a sensitive and interference-free analytical procedure was developed for the speciation of arsenic in samples of porewaters and sediments in Poyang Lake, China.展开更多
Solid state reaction between La (Ac)3·3/2H2O and 8-hydroxyquinoline (Oxine)was studied at a low heating temperature. La (Oxine)3 was synthesized by one step solid state reaction at 60℃, and the product is charac...Solid state reaction between La (Ac)3·3/2H2O and 8-hydroxyquinoline (Oxine)was studied at a low heating temperature. La (Oxine)3 was synthesized by one step solid state reaction at 60℃, and the product is characterized by elementary analysis, IR, XRD,photoacoustic spectra and flourenscence spectra. The influence of the temperature on solid state reaction was discussed.展开更多
基金supported by National 973 Program of China(2012CBA01206)National Natural Science Foundation of China(51222404)the financial support from State Key Laboratory of Rare Earth Resource Utilization,Changchun Institute of Applied Chemistry(RERU2011006)
文摘Synergistic solvent extraction of rare earth elements (REEs) from nitrate medium was investigated with mixtures of 8-hydroxyquinoline (HQ) and acidic organophosphorus extractants, bis(2,4,4-trimethylpentyl) dithiophosphinic acid (Cyanex 301) and bis(2,4,4-trimethylpentyl) monothiophosphinic acid (Cyanex 302). The extraction behavior of Cyanex 301/Cyanex 302 and their binary mixtures with HQ towards several lanthanoids (La, Nd, Sm, Tb, Ho, Tm) and yttrium (Y) was investigated. The separation ability of REEs was studied according to the various extraction effects. The extraction mechanisms for yttrium were studied with the methods of slope analysis and constant moles in the synergistic systems. The extracted compounds, the equilibrium constants, and thermodynamic functions were also determined.
基金The National Natural Science Foundation of China (No. 40103009 40573044) the Hundred-Talent Projects Program by ChineseAcademy of Sciences (No. 0560051057) and the Scientific Foundation of the Returned Overseas Chinese Scholars, State Education Ministry of China(No. 2004527)
文摘It was observed that the atomic fluorescence emission due to signal during the determination of As(Ⅲ) in the mixture of As(Ⅲ) and As(V) could has a 10% to 40% of fluorescence emission As(V). Besides, interferes from heavy metals such as Pb(Ⅱ), Cu(Ⅱ) can cause severe increase of the signals as compared to the insignificant effects caused by Cd(Ⅱ), Zn(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ). On the basis of further studies, the masking agent of 8-hydroxyquinoline was used as an efficient agent to eliminate interference of As(V) emission and the heavy metal of Cu^2+ and Pb^2+ in the measurements of arsenic species, After a series standard additions and CRM researches, a sensitive and interference-free analytical procedure was developed for the speciation of arsenic in samples of porewaters and sediments in Poyang Lake, China.
文摘Solid state reaction between La (Ac)3·3/2H2O and 8-hydroxyquinoline (Oxine)was studied at a low heating temperature. La (Oxine)3 was synthesized by one step solid state reaction at 60℃, and the product is characterized by elementary analysis, IR, XRD,photoacoustic spectra and flourenscence spectra. The influence of the temperature on solid state reaction was discussed.