Objective: To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics. Methods: A total of 129 patients with simple medial malleolus fract...Objective: To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics. Methods: A total of 129 patients with simple medial malleolus fracture were studied. Among them, 64 patients were treated with poly-D, L-lactic acid (PDLLA) absorbable screws, while the others were treated with metal screws. All the patients were followed up for 12-20 months (averaged 18.4 months) and the therapeutic effect was evaluated according to the American Orthopaedic Foot and Ankle Society clinical rating systems. Results: In absorbable screw group, we obtained excel- lent and good results in 62 cases (96.88%); in steel screw group, 61 cases (93.85%) achieved excellent and good results. There was no significant difference between the two groups. Conclusion: In the treatment of malleolus fracture, absorbable screw can achieve the same result compared with metal screw fixation. Absorbable screw is preferred due to its advantages of safety, cleanliness and avoiding the removal procedure associated with metallic implants.展开更多
目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、...目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、假手术组(C组)、空白对照组(D组),各9只。于术后4、8、12周取下颌骨标本,周围骨组织进行HE染色,观察各组植入钉周围情况。对术后4、8、12周的下颌骨大体标本拍摄Micro-CT图,使用VG Studio MAX软件进行三维重建,摆正数据样本,即颌骨颊侧造模处为轴向,动态分析植入钉体积、植入钉周围200μm环状区及骨缺损处的植入材料体积数、相对骨体积分数(BV/TV)、骨小梁厚度(Tb.Th)、骨小梁数(Tb.N)、骨小梁间隙(Tb.Sp)等骨愈合相关指标。结果HE染色结果显示,按3个时间可动态观察到A、B、C组骨缺损处骨性骨痂替代纤维性骨痂,形成类骨质,编织骨的过程符合正常骨损伤愈合的过程。Micro-CT结果显示,A、B组术后3个时间点的材料体积比较差异均无统计学意义(P>0.05);在3个时间点,4组植入钉周围200μm环状区中BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异均无统计学意义(P>0.05);在骨缺损处,A、B、C组三个时间点BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异无统计学意义(P>0.05);术后4周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);与C组比较,A、B组Tb.N差异有统计学意义(P<0.01)。术后8周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);术后12周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.Sp差异有统计学意义(P<0.05)。结论超声骨焊接技术其超声震荡产热作用下PDLLA材料对骨愈合性能无不良影响。展开更多
文摘Objective: To observe the therapeutic effect of absorbable screw in medial malleolus fracture and discuss its clinical application in orthopedics. Methods: A total of 129 patients with simple medial malleolus fracture were studied. Among them, 64 patients were treated with poly-D, L-lactic acid (PDLLA) absorbable screws, while the others were treated with metal screws. All the patients were followed up for 12-20 months (averaged 18.4 months) and the therapeutic effect was evaluated according to the American Orthopaedic Foot and Ankle Society clinical rating systems. Results: In absorbable screw group, we obtained excel- lent and good results in 62 cases (96.88%); in steel screw group, 61 cases (93.85%) achieved excellent and good results. There was no significant difference between the two groups. Conclusion: In the treatment of malleolus fracture, absorbable screw can achieve the same result compared with metal screw fixation. Absorbable screw is preferred due to its advantages of safety, cleanliness and avoiding the removal procedure associated with metallic implants.
文摘目的采用微焦点断层扫描(Micro-CT)评价超声骨焊接技术应用过程中超声震荡产热作用下PDLLA材料对骨愈合性能的影响。方法选择SPF级雄性新西兰大白兔36只,随机分为超声骨焊接技术辅助PDLLA材料组(A组)、拧入技术辅助PDLLA材料组(B组)、假手术组(C组)、空白对照组(D组),各9只。于术后4、8、12周取下颌骨标本,周围骨组织进行HE染色,观察各组植入钉周围情况。对术后4、8、12周的下颌骨大体标本拍摄Micro-CT图,使用VG Studio MAX软件进行三维重建,摆正数据样本,即颌骨颊侧造模处为轴向,动态分析植入钉体积、植入钉周围200μm环状区及骨缺损处的植入材料体积数、相对骨体积分数(BV/TV)、骨小梁厚度(Tb.Th)、骨小梁数(Tb.N)、骨小梁间隙(Tb.Sp)等骨愈合相关指标。结果HE染色结果显示,按3个时间可动态观察到A、B、C组骨缺损处骨性骨痂替代纤维性骨痂,形成类骨质,编织骨的过程符合正常骨损伤愈合的过程。Micro-CT结果显示,A、B组术后3个时间点的材料体积比较差异均无统计学意义(P>0.05);在3个时间点,4组植入钉周围200μm环状区中BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异均无统计学意义(P>0.05);在骨缺损处,A、B、C组三个时间点BV/TV、Tb.Th、Tb.N、Tb.Sp比较差异无统计学意义(P>0.05);术后4周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);与C组比较,A、B组Tb.N差异有统计学意义(P<0.01)。术后8周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.N、Tb.Sp差异有统计学意义(P<0.05);术后12周,与D组比较,A、B、C组BV/TV、Tb.Th、Tb.Sp差异有统计学意义(P<0.05)。结论超声骨焊接技术其超声震荡产热作用下PDLLA材料对骨愈合性能无不良影响。