期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision 被引量:24
1
作者 Guang-Wei Ji Yuan-Zhi Wu +14 位作者 Xu Wang Hua-Xiong Pan Ping Li Wan-Ying Du Zhi Qi An Huang Li-Wei Zhang Li Zhang Wen Chen Guang-Hua Liu Hui Xu Quan Li Ai-Hua Yuan Xiao-Ping He Guo-Hua Mei 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第25期4082-4085,共4页
AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models o... AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10^0, 10^2, 10^5, and 10^8 groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coil, Staphylococcus aureus and Pseudornonas aeruginosa at a concentration of 10^2, 10^5 and 10^8. On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type Ⅱ) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tieing silk suture were used in the controls. RESULTS: In all the groups except group 10^0, infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10^2, 10^5, and 10^8 (P 〈 0.05), but not in group 10^0 (P 〉 0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%)in the control groups. A significant difference between EK and the control groups (χ^2= 8.57, P 〈 0.01), and between EC and the control groups (χ^2 = 5.66, P 〈 0.05) was observed, but not between EK and EC (χ^2= 0.017, P 〉 0.05). CONCLUSION: High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications. 展开更多
关键词 High-frequency electric surgical knives Abdominal incision HEALING INFECTION
下载PDF
高频手术刀的技术发展与合理选择 被引量:3
2
作者 杨坤 郑博 邵蕾 《外科研究与新技术》 2017年第3期215-218,共4页
高频手术刀是临床手术使用最广泛的医疗设备之一,本文通过对高频手术刀的发展和技术创新,解析高频手术刀的各种类型以及它们的具体特性。提出我们如何去选择各种不同产品,包括对配套附件的选择要求。
关键词 高频手术刀 特征 选择
下载PDF
美国Valleylab公司SSE2L手术电刀故障1例
3
作者 张臣舜 《云南大学学报(自然科学版)》 CAS CSCD 2000年第S2期169-169,共1页
对造成SSE2L高频手术刀出现电切状态输出功率低,电凝状态无输出的故障作了较全面的分析,并给出排除的方法.
关键词 SSE2L高频手术刀 故障 检修
原文传递