实际种群分析法(VPA)是渔业资源评估的经典模型之一,也是总允许捕捞配额(TAC)计算的主要模型之一。由于VPA方法本身具有不确定性,单纯的分年龄组产量数据不能计算最末年的捕捞死亡系数(和种群数量),所以它通常需要分年龄组产量数据和附...实际种群分析法(VPA)是渔业资源评估的经典模型之一,也是总允许捕捞配额(TAC)计算的主要模型之一。由于VPA方法本身具有不确定性,单纯的分年龄组产量数据不能计算最末年的捕捞死亡系数(和种群数量),所以它通常需要分年龄组产量数据和附属数据。VPA的调谐方法发源于欧洲,它们简单、易于理解和不需要繁杂的计算,在实际的渔业资源评估中有着广泛的应用。文章研究了最具有典型性的3种VPA调谐方法,JAM(judicious average method)、LS(Laurec and Shepherd method)和Hybrid。应用模拟数据的研究表明,3种方法在捕捞死亡系数稳定时可以较准确地估计补充值。当捕捞死亡系数随时间增加时,LS方法相对于其它2种方法有较优的表现。当捕捞死亡系数随时间减少时,JAM方法有较优的表现。展开更多
Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the...Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.展开更多
Recently ionic liquids(ILs) are introduced as novel dual function gas hydrate inhibitors. However, no desired gas hydrate inhibition has been reported due to poor IL selection and/or tuning method. Trial & error a...Recently ionic liquids(ILs) are introduced as novel dual function gas hydrate inhibitors. However, no desired gas hydrate inhibition has been reported due to poor IL selection and/or tuning method. Trial & error as well as selection based on existing literature are the methods currently employed for selecting and/or tuning ILs. These methods are probabilistic, time consuming, expensive and may not result in selecting high performance ILs for gas hydrate mitigation. In this work, COSMO-RS is considered as a prescreening tool of ILs for gas hydrate mitigation by predicting the hydrogen bonding energies(E_(HB)) of studied IL inhibitors and comparing the predicted E_(HB) to the depression temperature(?) and induction time. Results show that, predicted EHBand chain length of ILs strongly relate and significantly affect the gas hydrate inhibition depression temperature but correlate moderately(R = 0.70) with average induction time in literature. It is deduced from the results that, ? increases with increasing IL EHBand/or decreases with increasing chain length. However, the cation–anion pairing of ILs also affects IL gas hydrate inhibition performance. Furthermore, a visual and better understanding of IL/water behavior for gas hydrate inhibition in terms of hydrogen bond donor and acceptor interaction analysis is also presented by determining the sigma profile and sigma potential of studied IL cations and anions used for gas hydrate mitigation for easy IL selection.展开更多
文摘实际种群分析法(VPA)是渔业资源评估的经典模型之一,也是总允许捕捞配额(TAC)计算的主要模型之一。由于VPA方法本身具有不确定性,单纯的分年龄组产量数据不能计算最末年的捕捞死亡系数(和种群数量),所以它通常需要分年龄组产量数据和附属数据。VPA的调谐方法发源于欧洲,它们简单、易于理解和不需要繁杂的计算,在实际的渔业资源评估中有着广泛的应用。文章研究了最具有典型性的3种VPA调谐方法,JAM(judicious average method)、LS(Laurec and Shepherd method)和Hybrid。应用模拟数据的研究表明,3种方法在捕捞死亡系数稳定时可以较准确地估计补充值。当捕捞死亡系数随时间增加时,LS方法相对于其它2种方法有较优的表现。当捕捞死亡系数随时间减少时,JAM方法有较优的表现。
文摘Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.
文摘Recently ionic liquids(ILs) are introduced as novel dual function gas hydrate inhibitors. However, no desired gas hydrate inhibition has been reported due to poor IL selection and/or tuning method. Trial & error as well as selection based on existing literature are the methods currently employed for selecting and/or tuning ILs. These methods are probabilistic, time consuming, expensive and may not result in selecting high performance ILs for gas hydrate mitigation. In this work, COSMO-RS is considered as a prescreening tool of ILs for gas hydrate mitigation by predicting the hydrogen bonding energies(E_(HB)) of studied IL inhibitors and comparing the predicted E_(HB) to the depression temperature(?) and induction time. Results show that, predicted EHBand chain length of ILs strongly relate and significantly affect the gas hydrate inhibition depression temperature but correlate moderately(R = 0.70) with average induction time in literature. It is deduced from the results that, ? increases with increasing IL EHBand/or decreases with increasing chain length. However, the cation–anion pairing of ILs also affects IL gas hydrate inhibition performance. Furthermore, a visual and better understanding of IL/water behavior for gas hydrate inhibition in terms of hydrogen bond donor and acceptor interaction analysis is also presented by determining the sigma profile and sigma potential of studied IL cations and anions used for gas hydrate mitigation for easy IL selection.