Aim To develop a liquid chromatographic-tandem mass spectrometric (LC-MS-MS)method to determine clarithromycin in human plasma. Methods The analyte and internal standardroxithromycin were extracted from plasma samples...Aim To develop a liquid chromatographic-tandem mass spectrometric (LC-MS-MS)method to determine clarithromycin in human plasma. Methods The analyte and internal standardroxithromycin were extracted from plasma samples by n-nexane-dichloromethane-isopropanol(300:150:15, V/V/V) and chromalographed on a C_(18) column. The mobile phase consisted ofmethanol-water-formic acid (80 = 20:1, V/V/V) . Detection was performed on a triple quadrupoletandem mass spectrometer via electrospray ionization source (ESI) in the positive mode. Results Themethod had a lower limit of quantification of 10.0 ng·mL^(-1) when 0.2 mL plasma was used. Thelinear calibration curves were obtained in the concentration range of 10.0 - 5000 ng·mL^(-1) . Theintra- and inter-run precisions were lower than 3.3% in terms of relative standard deviation (RSD),and the accuracy ranged +- 0.7% in terms of relative error (RE). T_(max), C_(max), T_(1/2) andAUC_(0-24h), values were found to be (3.1 +- 2.7)h, (8 750+-4734) ng·mL^(-1), (5.3+-2.2) h, and(5932+-2449)ng·mL^(-1), respectively, after a single oral dose of 250 mg clarithromycin tablet to18 volunteers. Conclusion This validated method was successful in the evaluation of phaimacokineticprofiles of clarithromycin tablets administered to 18 healthy male volunteers.展开更多
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto...To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.展开更多
文摘Aim To develop a liquid chromatographic-tandem mass spectrometric (LC-MS-MS)method to determine clarithromycin in human plasma. Methods The analyte and internal standardroxithromycin were extracted from plasma samples by n-nexane-dichloromethane-isopropanol(300:150:15, V/V/V) and chromalographed on a C_(18) column. The mobile phase consisted ofmethanol-water-formic acid (80 = 20:1, V/V/V) . Detection was performed on a triple quadrupoletandem mass spectrometer via electrospray ionization source (ESI) in the positive mode. Results Themethod had a lower limit of quantification of 10.0 ng·mL^(-1) when 0.2 mL plasma was used. Thelinear calibration curves were obtained in the concentration range of 10.0 - 5000 ng·mL^(-1) . Theintra- and inter-run precisions were lower than 3.3% in terms of relative standard deviation (RSD),and the accuracy ranged +- 0.7% in terms of relative error (RE). T_(max), C_(max), T_(1/2) andAUC_(0-24h), values were found to be (3.1 +- 2.7)h, (8 750+-4734) ng·mL^(-1), (5.3+-2.2) h, and(5932+-2449)ng·mL^(-1), respectively, after a single oral dose of 250 mg clarithromycin tablet to18 volunteers. Conclusion This validated method was successful in the evaluation of phaimacokineticprofiles of clarithromycin tablets administered to 18 healthy male volunteers.
文摘To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.