Purpose: To study the correlation between functional and structural loss in chronic glaucoma, as detected by Frequency Doubling Technology (FDT) and Heilderberg Retina Tomograph (HRT). Material and Methods: 60 eyes of...Purpose: To study the correlation between functional and structural loss in chronic glaucoma, as detected by Frequency Doubling Technology (FDT) and Heilderberg Retina Tomograph (HRT). Material and Methods: 60 eyes of 60 patients with either ocular hypertension or chronic open-angle glaucoma underwent visual field testing with both standard展开更多
目的:30℃的环境下.对钇稳定四方多晶氧化锆陶瓷(Y—TZP)支架-饰面-复合树脂块三层结构复合体进行口腔离轴运动步进应力疲劳测试,测定不同饰瓷技术对三层结构复合体的破坏模式和可靠性的影响。方法:将CAD/CAM技术制作的Y—TZP支...目的:30℃的环境下.对钇稳定四方多晶氧化锆陶瓷(Y—TZP)支架-饰面-复合树脂块三层结构复合体进行口腔离轴运动步进应力疲劳测试,测定不同饰瓷技术对三层结构复合体的破坏模式和可靠性的影响。方法:将CAD/CAM技术制作的Y—TZP支架随机分为两组,每组24个。试验组和对照组分别采用失蜡压铸技术(IPS e.max ZirPress,Ivoclar Vivadent,test group press,n=24)和手工堆瓷技术(IPS e.max Ceram,Ivoclar Vivadent.control group press,n=24)。完成的试件尺寸为12mm×12mm×0.7mm。使用树脂粘结剂(Alloy Primer and Panavia21,Kuraray)将饰瓷完成的瓷块粘结于复合树脂块(12mm×12mm×4mm,Z-100)上.在水中存放7d后进行疲劳试验。使用带有碳化钨硬质合金球(r=318mm)的力学测试机(EL-3300,Bose/Enduratec),设定三个等级的载荷力,对试件进行口腔离轴运动步进应力疲劳测试。对试件加载应力.直到裂纹达到结合界面。试件被弯折,与应力方向成300.以模拟后牙牙尖的斜度。进行单循环加载试验.直至试件破坏.记录单循环临界载荷值.即步进应力(n=3)。结果:试验组临界载荷为825N,对照组为803N。不论采用何种饰瓷技术.Y—TZP支架-饰面-复合树脂块三层结构复合体均出现从表面至结合界面的锥形深裂纹.Y—TZP支架未出现径向断裂。记录Weibull应力水平概率曲线(AItaPro,ReliaSoft).进行200N、10万次循环加载,计算试件的可靠性。两组试件的可靠性相似(试验组为0.54,对照组为0.51)。结论:负载模拟骀力后,两种饰瓷技术制作的Y—TZP-饰面复合体的步进应力疲劳可靠性相似。两种饰瓷技术的破坏模式相同.均为局限于饰面瓷的表面破坏。展开更多
文摘Purpose: To study the correlation between functional and structural loss in chronic glaucoma, as detected by Frequency Doubling Technology (FDT) and Heilderberg Retina Tomograph (HRT). Material and Methods: 60 eyes of 60 patients with either ocular hypertension or chronic open-angle glaucoma underwent visual field testing with both standard
文摘目的:30℃的环境下.对钇稳定四方多晶氧化锆陶瓷(Y—TZP)支架-饰面-复合树脂块三层结构复合体进行口腔离轴运动步进应力疲劳测试,测定不同饰瓷技术对三层结构复合体的破坏模式和可靠性的影响。方法:将CAD/CAM技术制作的Y—TZP支架随机分为两组,每组24个。试验组和对照组分别采用失蜡压铸技术(IPS e.max ZirPress,Ivoclar Vivadent,test group press,n=24)和手工堆瓷技术(IPS e.max Ceram,Ivoclar Vivadent.control group press,n=24)。完成的试件尺寸为12mm×12mm×0.7mm。使用树脂粘结剂(Alloy Primer and Panavia21,Kuraray)将饰瓷完成的瓷块粘结于复合树脂块(12mm×12mm×4mm,Z-100)上.在水中存放7d后进行疲劳试验。使用带有碳化钨硬质合金球(r=318mm)的力学测试机(EL-3300,Bose/Enduratec),设定三个等级的载荷力,对试件进行口腔离轴运动步进应力疲劳测试。对试件加载应力.直到裂纹达到结合界面。试件被弯折,与应力方向成300.以模拟后牙牙尖的斜度。进行单循环加载试验.直至试件破坏.记录单循环临界载荷值.即步进应力(n=3)。结果:试验组临界载荷为825N,对照组为803N。不论采用何种饰瓷技术.Y—TZP支架-饰面-复合树脂块三层结构复合体均出现从表面至结合界面的锥形深裂纹.Y—TZP支架未出现径向断裂。记录Weibull应力水平概率曲线(AItaPro,ReliaSoft).进行200N、10万次循环加载,计算试件的可靠性。两组试件的可靠性相似(试验组为0.54,对照组为0.51)。结论:负载模拟骀力后,两种饰瓷技术制作的Y—TZP-饰面复合体的步进应力疲劳可靠性相似。两种饰瓷技术的破坏模式相同.均为局限于饰面瓷的表面破坏。